X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages

被引:14
作者
Campillo-Rivera, Guillermo Eduardo [1 ]
Torres-Cortes, Carina Oliva [1 ]
Vazquez-Banuelos, Joel [1 ]
Garcia-Reyna, Mayra Guadalupe [1 ]
Marquez-Mata, Claudia Angelica [2 ]
Vasquez-Arteaga, Marcial [3 ]
Vega-Carrillo, Hector Rene [4 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Ingn Elect, Programa Doctorado Ingn & Tecnol Aplicada, Ave Lopez Velarde 800, Zacatecas 98000, Zac, Mexico
[2] TecNM Inst Tecnol Aguascalientes, Ave Adolfo Lopez Mateos 1801 Ote, Aguascalientes 20256, Ags, Mexico
[3] Univ Sr Sipan, Chiclayo 14000, Peru
[4] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Cipres 10, Zacatecas 98060, Zac, Mexico
关键词
X-rays; Spectra; Air kerma; Ambient dose equivalent; Gamma factors; Monte Carlo; AIR-KERMA RATE; MONTE-CARLO PROGRAM; DIAGNOSTIC-RADIOLOGY; CONVERSION COEFFICIENTS; RATE CONSTANTS; RADIATION; FILTRATION; FLUENCE;
D O I
10.1016/j.radphyschem.2021.109437
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The energy distribution of photons (spectrum) produced in X-ray generators, or X-ray tubes, depends on current, voltage and the target/filter combination; in turn, the dose depends on the spectrum. During the X-ray tube operation, the dose is due the direct beam or useful beam, the leaking out from the X-ray unit, and those photons scattered by the patient. The dose rate must be reduced to allowable limits using a shielding. In the shielding design an important parameter is the dose normalized to the current and the time, that in this work we named Gamma factor, as the factor used for gamma-ray sources. In this work analog Monte Carlo methods were used to calculate the photon spectra and the Gamma factors for air-Kerma and the Ambient dose equivalent for 70, 80, 90, 100 and 120 kV X-ray tubes having tungsten target and aluminum filter. The mean energies of photon spectra were calculated and the conversion coefficients for H*(10) and Ka per unit fluence were calculated and compared with the coefficients for monoenergetic photons. The glass enclosure and the filter eliminate the low-energy photons; calculated spectra show the continuous X-ray distribution due to Bremsstrahlung and the discrete distribution, due to characteristics X-rays. Photon fluences and doses depend on the X-ray unit voltage. Both gamma factors are similar to values recommended in norms while the fluence-to-dose (Ka and H*(10)) conversion coefficients in function of the mean energy are larger than the fluence-to-dose conversion coefficients for monoenergetic photons.
引用
收藏
页数:8
相关论文
共 57 条
[1]   Neutron-fluence-to-dose conversion coefficients in an anthropomorphic phantom [J].
Alghamdi, AA ;
Ma, A ;
Tzortzis, M ;
Spyrou, NM .
RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) :606-611
[2]  
[Anonymous], 1996, CONVERSION COEFFICIE
[3]  
[Anonymous], 2004, 147 NCRP
[4]  
[Anonymous], 1993, 116 NCRP
[5]  
[Anonymous], 2013, 6812 DIN
[6]  
Ans, 1977, 6111997 ANSANS
[7]   Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C [J].
Ay, MR ;
Shahriari, M ;
Sarkar, S ;
Adib, M ;
Zaidi, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21) :4897-4917
[8]   Effective dose in diagnostic radiology as a function of x-ray beam filtration for a constant exit dose and constant film density [J].
Behrman, RH ;
Yasuda, G .
MEDICAL PHYSICS, 1998, 25 (05) :780-790
[9]   On the stopping of fast particles and on the creation of positive electrons [J].
Bethe, H ;
Heitler, W .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-CONTAINING PAPERS OF A MATHEMATICAL AND PHYSICAL CHARACTER, 1934, 146 (A856) :0083-0112
[10]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120