Design optimization of office building envelope configurations for energy conservation

被引:90
作者
Lin, Yu-Hao [1 ]
Tsai, Kang-Ting [2 ]
Lin, Min-Der [3 ]
Yang, Ming-Der [4 ]
机构
[1] Natl Chung Hsing Univ, Ctr Environm Restorat & Disaster Reduct, 250 Kuo Kuang Rd, Taichung 402, Taiwan
[2] Natl Chung Hsing Univ, Program Landscape & Recreat, 250 Kuo Kuang Rd, Taichung 402, Taiwan
[3] Natl Chung Hsing Univ, Dept Environm Engn, 250 Kuo Kuang Rd, Taichung 402, Taiwan
[4] Natl Chung Hsing Univ, Dept Civil Engn, 250 Kuo Kuang Rd, Taichung 402, Taiwan
关键词
Green building; Tabu search (TS); Optimization; Building envelope; Energy conservation; SEWERAGE REHABILITATION; COMMERCIAL BUILDINGS; PERFORMANCE; ALGORITHM; MODEL; EFFICIENCY; SYSTEMS;
D O I
10.1016/j.apenergy.2016.03.018
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Designing envelope configurations of office building with the low construction cost and energy consumption is a discrete optimization problem. The configuration is currently determined merely on architects' experiences resulting in an inefficient expense or by building energy performance simulation which is time-intensive and involves complex processes. Based on an efficient regression equation to substitute complex energy simulators, this study developed an Office Building envelope Energy performance and configuration Model (OBEM) to provide envelope configurations, including construction material, sunshade type, sunshade length, window number, and window length and width for architects' reference. Also, Tabu search, which is effective in solving discrete optimization problems, was integrated with OBEM into an Optimal OBEM decision support system (OPOBEM). The OPOBEM was applied to a real office building construction for optimizing its envelope configuration at minimum construction budget under the energy conservation regulations of green buildings. The result shows that the optimized installation of sunshade type efficiently reduces solar heat gain according to the high variation of the sunshade coefficient, thus achieves the goal of energy conservation and reduces the envelope costs. Compared with architects' manual estimation, the optimized envelope design realizes nearly 41% budget savings, thus demonstrating the feasibility of the proposed OPOBEM. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:336 / 346
页数:11
相关论文
共 48 条
[1]   A tabu search-based algorithm for the Fuzzy Clustering Problem [J].
Al-Sultan, KS ;
Fedjki, CA .
PATTERN RECOGNITION, 1997, 30 (12) :2023-2030
[2]   A review on simulation-based optimization methods applied to building performance analysis [J].
Anh-Tuan Nguyen ;
Reiter, Sigrid ;
Rigo, Philippe .
APPLIED ENERGY, 2014, 113 :1043-1058
[3]  
[Anonymous], 2013, TABU SEARCH
[4]   Optimization of envelope and HVAC systems selection for residential buildings [J].
Bichiou, Youssef ;
Krarti, Moncef .
ENERGY AND BUILDINGS, 2011, 43 (12) :3373-3382
[5]   Development of a multicriteria tool for optimizing the renovation of buildings [J].
Chantrelle, Fanny Pernodet ;
Lahmidi, Hicham ;
Keilholz, Werner ;
El Mankibi, Mohamed ;
Michel, Pierre .
APPLIED ENERGY, 2011, 88 (04) :1386-1394
[6]   Evaluating water conservation measures for Green Building in Taiwan [J].
Cheng, CL .
BUILDING AND ENVIRONMENT, 2003, 38 (02) :369-379
[7]  
Chou S, 1986, ASHRAE T US, V92
[8]  
Chou SK, 1997, INT J ENERG RES, V21, P169, DOI 10.1002/(SICI)1099-114X(199702)21:2<169::AID-ER232>3.0.CO
[9]  
2-3
[10]   DEVELOPMENT OF AN ENERGY-ESTIMATING EQUATION FOR LARGE COMMERCIAL BUILDINGS [J].
CHOU, SK ;
CHANG, WL .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1993, 17 (08) :759-773