A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images

被引:127
作者
Gemignani, Vincenzo [1 ]
Faita, Francesco
Ghiadoni, Lorenzo
Poggianti, Elisa
Demi, Marcello
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[2] Univ Pisa, Dept Internal Med, I-56126 Pisa, Italy
[3] Esaote SpA, I-16153 Genoa, Italy
关键词
brachial artery; flow-mediated dilation; real-time systems; ultrasound;
D O I
10.1109/TMI.2006.891477
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The measurement of the brachial artery diameter is frequently used in clinical studies for evaluating the flow-mediated dilation and, in conjunction with the blood pressure value, for assessing arterial stiffness. This paper presents a system for computing the brachial artery diameter in real-time by analyzing B-mode ultrasound images. The method is based on a robust edge detection algorithm which is used to automatically locate the two walls of the vessel. The measure of the diameter is obtained with subpixel precision and with a temporal resolution of 25 samples/s, so that the small dilations induced by the cardiac cycle can also be retrieved. The algorithm is implemented on a standalone video processing board which acquires the analog video signal from the ultrasound equipment. Results are shown in real-time on a graphical user interface. The system was tested both on synthetic ultrasound images and in clinical studies of flow-mediated dilation. Accuracy, robustness, and intra/inter observer variability of the method were evaluated.
引用
收藏
页码:393 / 404
页数:12
相关论文
共 33 条
[1]  
ANDREI RM, 2005, THESIS PISA U PISA
[2]   A novel ultrasound instrument for investigation of arterial mechanics [J].
Bambi, G ;
Morganti, T ;
Ricci, S ;
Boni, E ;
Guidi, F ;
Palombo, C ;
Tortoli, P .
ULTRASONICS, 2004, 42 (1-9) :731-737
[3]   Automatic evaluation of arterial diameter variation from vascular echographic images [J].
Beux, F ;
Carmassi, S ;
Salvetti, MV ;
Ghiadoni, L ;
Huang, Y ;
Taddei, S ;
Salvetti, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) :1621-1629
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Measures of brachial artery distensibility in relation to coronary calcification [J].
Budoff, MJ ;
Flores, F ;
Tsai, J ;
Frandsen, T ;
Yamamoto, H ;
Takasu, J .
AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) :350-355
[6]   CIGARETTE-SMOKING IS ASSOCIATED WITH DOSE-RELATED AND POTENTIALLY REVERSIBLE IMPAIRMENT OF ENDOTHELIUM-DEPENDENT DILATION IN HEALTHY-YOUNG ADULTS [J].
CELERMAJER, DS ;
SORENSEN, KE ;
GEORGAKOPOULOS, D ;
BULL, C ;
THOMAS, O ;
ROBINSON, J ;
DEANFIELD, JE .
CIRCULATION, 1993, 88 (05) :2149-2155
[7]   NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS [J].
CELERMAJER, DS ;
SORENSEN, KE ;
GOOCH, VM ;
SPIEGELHALTER, DJ ;
MILLER, OI ;
SULLIVAN, ID ;
LLOYD, JK ;
DEANFIELD, JE .
LANCET, 1992, 340 (8828) :1111-1115
[8]   Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery - A report of the International Brachial Artery Reactivity Task Force [J].
Corretti, MC ;
Anderson, TJ ;
Benjamin, EJ ;
Celermajer, D ;
Charbonneau, F ;
Creager, MA ;
Deanfield, J ;
Drexler, H ;
Gerhard-Herman, M ;
Herrington, D ;
Vallance, P ;
Vita, J ;
Vogel, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) :257-265
[9]   Smoking correlates with flow-mediated brachial artery vasoactivity but not cold pressor vasoactivity in men with coronary artery disease [J].
Corretti, MC ;
Plotnick, GD ;
Vogel, RA .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01) :11-17
[10]  
FAN YS, 2000, COMPUTER INTEGRATED, V6, P1