A carbon nanotube sponge as an adsorbent for vapor preconcentration of aromatic volatile organic compounds

被引:17
作者
Bang, Juyeon [1 ,2 ]
You, Dong-Wook [1 ,2 ]
Jang, Yeonhee [1 ,2 ]
Oh, Jun-Sik [3 ]
Jung, Kwang-Woo [1 ,2 ]
机构
[1] Wonkwang Univ, Dept Chem, 460 Iksandaero, Jeonbuk 54538, South Korea
[2] Wonkwang Univ, Nanosci & Technol Inst, 460 Iksandaero, Jeonbuk 54538, South Korea
[3] Ssufine Corp, 460 Iksandaero, Iksan 54538, Jeonbuk, South Korea
关键词
Carbon nanotube (CNT) sponge; Preconcentrator; Aromatic volatile organic compounds (VOCs); Enrichment factor; Trace analysis; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; MICRO GAS PRECONCENTRATOR; EXTRACTION ADSORBENT; PERFORMANCE; AIR; SYSTEMS; MODULE; VOCS; GC;
D O I
10.1016/j.chroma.2019.460363
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A carbon nanotube (CNT) sponge was synthesized and examined as an adsorptive material for a thermally desorbed preconcentrator for volatile organic compounds (VOCs). The porous sponge-like material, retaining the intrinsic properties of individual multiwalled (MW) CNTs, was fabricated using spray pyrolysis chemical vapor deposition (CVD). The square pillar form of the CNT sponge was enclosed in a 1/4" glass tube with fittings for flow-through sampling. Flow of a direct current through the CNT sponge allowed rapid thermal heating to a surface temperature of 264.7 degrees at a rate of 481.5 degrees/s and a narrow desorption bandwidth of 0.74 s. The preconcentration concept was validated using gas chromatographic analysis of an aromatic VOC mixture, including benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors at concentrations of 100 parts per billion (ppb). With an adsorption volume of only 100 ml, the enrichment factor of each analyte was 300 (B), 240 (T), 210 (E), and 200 (X), enabling sensitive measurements with limits of detection at the parts per trillion level. Sequential desorption experiments confirmed that a single desorption process evaporates all the analytes inside the preconcentrator with >96% efficiency. There was no humidity effect and no sign of performance degradation after continuous operation for 45 repeated cycles. These results demonstrate that CNT sponges are a suitable material for the enrichment and sensitive determination of VOCs at trace levels. Thus, CNT sponge preconcentrators are advantageous in a variety of applications that permit fast and accurate real-time measurements, including ambient air and workplace air monitoring. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 55 条
[1]   Improved performance of micro-fabricated preconcentrators using silica nanoparticles as a surface template [J].
Akbar, Muhammad ;
Wang, Dong ;
Goodman, Ryan ;
Hoover, Ashley ;
Rice, Gary ;
Heflin, James R. ;
Agah, Masoud .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1322 :1-7
[2]   Characterization of poly(2,6-diphenyl-p-phenylene oxide) films as adsorbent for microfabricated preconcentrators [J].
Alfeeli, Bassam ;
Jain, Vaibhav ;
Johnson, Richard K. ;
Beyer, Frederick L. ;
Heflin, James R. ;
Agah, Masoud .
MICROCHEMICAL JOURNAL, 2011, 98 (02) :240-245
[3]   Atmospheric degradation of volatile organic compounds [J].
Atkinson, R ;
Arey, J .
CHEMICAL REVIEWS, 2003, 103 (12) :4605-4638
[4]   Molecularly imprinted polymer-hollow fiber microextraction of hydrophilic fluoroquinolone antibiotics in environmental waters and urine samples [J].
Barahona, Francisco ;
Albero, Beatriz ;
Luis Tadeo, Jose ;
Martin-Esteban, Antonio .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1587 :42-49
[5]   Effect of hydrogen on catalyst nanoparticles in carbon nanotube growth [J].
Behr, Michael J. ;
Gaulding, E. Ashley ;
Mkhoyan, K. Andre ;
Aydil, Eray S. .
JOURNAL OF APPLIED PHYSICS, 2010, 108 (05)
[6]   Fabrication and characterisation of microporous activated carbon-based pre-concentrators for benzene vapours [J].
Blanco, F. ;
Vilanova, X. ;
Fierro, V. ;
Celzard, A. ;
Ivanov, P. ;
Llobet, E. ;
Canellas, N. ;
Ramirez, J. L. ;
Correig, X. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) :90-98
[7]   Novel family of multi-layer cartridges filled with a new carbon adsorbent for the quantitative determination of volatile organic compounds in the atmosphere [J].
Brancaleoni, E ;
Scovaventi, M ;
Frattoni, M ;
Mabilia, R ;
Ciccioli, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 845 (1-2) :317-328
[8]   Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol a, 4-n-nonylphenol, and 4-tert-octylphenol [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2517-2521
[9]   Q-graphene-scaffolded covalent organic frameworks as fluorescent probes and sorbents for the fluorimetry and removal of copper ions [J].
Cai, Yuanyuan ;
Jiang, Yao ;
Feng, Luping ;
Hua, Yue ;
Liu, Huan ;
Fan, Chuan ;
Yin, Mengyuan ;
Li, Shuai ;
Lv, Xiaoxia ;
Wang, Hua .
ANALYTICA CHIMICA ACTA, 2019, 1057 :88-97
[10]   A micro gas preconcentrator with improved performance for pollution monitoring and explosives detection [J].
Camara, E. H. M. ;
Breuil, P. ;
Briand, D. ;
de Rooij, N. F. ;
Pijolat, C. .
ANALYTICA CHIMICA ACTA, 2011, 688 (02) :175-182