Power spectral analysis of heart rate variability during helium pneumoperitoneum - The mechanism of increased cardiac sympathetic activity and its clinical significance

被引:13
作者
Bickel, A [1 ]
Kukuev, E
Popov, O
Ivry, S
Roguin, N
Yahalom, M
Eitan, A
机构
[1] Western Galilee Hosp, Dept Surg, IL-22100 Nahariyya, Israel
[2] Western Galilee Hosp, Dept Anesthesiol, IL-22100 Nahariyya, Israel
[3] Western Galilee Hosp, Dept Cardiol, IL-22100 Nahariyya, Israel
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2005年 / 19卷 / 01期
关键词
pneumoperitoneum; helium; power spectral analysis; laparoscopy; autonomic nervous system;
D O I
10.1007/s00464-003-9304-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Carbon dioxide pneumoperitoneum (PP) is known to induce increased cardiac sympathetic expression. The role of the insufflated gas involved in this mechanism should be elucidated in an attempt to eliminate its possible serious consequences. Methods: Twenty-five patients Undergoing elective laparoscopic cholecystectomy were prospectively analyzed for cardiac autonomic nervous activity by spectral heart rate variability. In 15 patients, helium was used as CO2 substitution for abdominal insufflation (study Group). Four frequency bands of interest were obtained from the power spectrum of R-R intervals, as well as the ratio between the low and high frequency (LF/HF), using the fast Fourier transformation algorithm to characterize the synergy of both autonomic branches during PP. Results: Significantly increased values of the power spectrum related to the LF and VLF bands (from 130 to 377 msec(2)/Hz and from 145 to 516 msec(2)/Hz, respectively) were inspected during CO? PP, as well as increased LF/LH ratio (2.1). Using helium as CO2 substitution has eliminated the significant changes in the power spectrum that reflect increased cardiac sympathetic activity. Conclusions: The elimination of sympathetic predorninance by helium PP indicates the central role of CO2 in establishing this phenomena. Considering this information ana its other known advantages, helium should be considered for use during prolonged laparoscopic procedures for high-risk patients.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 24 条
[1]  
Akselrod S., 1995, Heart Rate Variability, P147
[2]   Power spectral analysis of heart rate variability during positive pressure pneumoperitoneum - The significance of increased cardiac sympathetic expression [J].
Bickel, A ;
Yahalom, M ;
Roguin, N ;
Frankel, R ;
Breslava, J ;
Ivry, S ;
Eitan, A .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2002, 16 (09) :1341-1344
[3]  
BICKEL A, 2004, IN PRESS AM J SURG
[4]   Intraperitoneal immunity and pneumoperitoneum [J].
Chekan, EG ;
Nataraj, C ;
Clary, EM ;
Hayward, TZ ;
Brody, FJ ;
Stamat, JC ;
Fina, MC ;
Eubanks, WS ;
Westcott, CJ .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (11) :1135-1138
[5]  
Davidson BS, 1996, SURG ENDOSC-ULTRAS, V10, P301
[6]   Helium and carbon dioxide pneumoperitoneum in patients with pheochromocytoma undergoing laparoscopic adrenalectomy [J].
Fernández-Cruz, L ;
Sáenz, A ;
Taurá, P ;
Sabater, L ;
Astudillo, E ;
Fontanals, J .
WORLD JOURNAL OF SURGERY, 1998, 22 (12) :1250-1255
[7]   The safety of helium for abdominal insufflation [J].
Fleming, RYD ;
Dougherty, TB ;
Feig, BW .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1997, 11 (03) :230-234
[8]   DECREASED MAGNITUDE OF HEART-RATE SPECTRAL COMPONENTS IN CORONARY-ARTERY DISEASE - ITS RELATION TO ANGIOGRAPHIC SEVERITY [J].
HAYANO, J ;
SAKAKIBARA, Y ;
YAMADA, M ;
OHTE, N ;
FUJINAMI, T ;
YOKOYAMA, K ;
WATANABE, Y ;
TAKATA, K .
CIRCULATION, 1990, 81 (04) :1217-1224
[9]   Impact of carbon dioxide and helium insufflation on cardiorespiratory function during prolonged pneumoperitoneum in an experimental rat model [J].
Hazebroek, EJ ;
Haitsma, JJ ;
Lachmann, B ;
Steyerberg, EW ;
de Bruin, RWF ;
Bouvy, ND ;
Bonjer, HJ .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2002, 16 (07) :1073-1078
[10]  
HO HS, 1992, ARCH SURG-CHICAGO, V127, P928