Comparative study of magnetic beads and microplates as supports in heterogeneous amplified assay of miRNA-141 by using mismatched catalytic hairpin assembly reaction

被引:3
作者
Safenkova, Irina, V [1 ]
Burkin, Konstantin M. [2 ]
Bodulev, Oleg L. [2 ]
Razo, Shyatesa C. [1 ,3 ]
Ivanov, Aleksandr, V [1 ]
Zherdev, Anatoly, V [1 ]
Dzantiev, Boris B. [1 ]
Sakharov, Ivan Yu [2 ]
机构
[1] Russian Acad Sci, AN Bach Inst Biochem, Res Ctr Biotechnol, Leninsky Prospect 33, Moscow 119071, Russia
[2] Lomonosov Moscow State Univ, Dept Chem, Bldg 1, Moscow 119991, Russia
[3] RUDN Univ, Agr & Technol Inst, 8-2 Mikluho Maklaya St, Moscow 117198, Russia
基金
俄罗斯科学基金会; 俄罗斯基础研究基金会;
关键词
Magnetic beads; Microplate; Heterogeneous assay; miRNA; Mismatched catalytic hairpin assembly; ACID; AMPLIFICATION; IMMUNOASSAY; BIOSENSORS;
D O I
10.1016/j.talanta.2022.123535
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetic beads (MBs) are often considered as an effective carrier in heterogeneous assays due to the simplicity of separation and washing, and the ability to increase and control the surface area. However, the effect of the MBs surface on the analytical parameters is poorly characterized and is often postulated from intuitive considerations. Herein, experimental evaluation through the comparison of MBs and microwell plate was carried out using the miRNA-141 (biomarker for cancer) as a target, the detection of which was performed by chemiluminescent assay with a homogeneous mismatched catalytic hairpin assembly (mCHA) reaction. The mCHA reaction produced double-stranded (ds) DNA labeled at one end with fluorescein (Flu) for capture with anti-Flu antibodies immobilized on a solid carrier, on the other end with biotin for recognition by streptavidin-polyperoxidase conjugate. The conditions of immobilization of anti-Flu antibody on MBs (a diameter of 440 nm) performed using a carbodiimide method were optimized by varying the antibody concentration in the reaction solution. It was shown that the dependence of chemiluminescent signal as a function of the concentration of anti-FluAb-MBs conjugates had a bell-shaped character. The maximum chemiluminescence was produced at the concentration of the conjugates of 2 x 10(9) particles/mL, with a surface area of 65 mm(2). The identical surface area was used upon the assay performance with polystyrene microplates. Comparison of MBs-and microplate-assays for miRNA-141 determination showed that the obtained calibration curves and their detection limit values were the same and did not depend on the used carrier. The results showed that the choice of a carrier for heterogeneous assays should be guided by the convenience of the assay performance, not its surface area.
引用
收藏
页数:7
相关论文
共 47 条
[31]   3-(10'-Phenothiazinyl)propionic acid is a potent primary enhancer of peroxidase-induced chemiluminescence and its application in sensitive ELISA of methylglyoxal-modified low density lipoprotein [J].
Sakharov, Ivan Yu ;
Demiyanova, Alexandra S. ;
Gribas, Anastasia V. ;
Uskova, Natalia A. ;
Efremov, Evgeny E. ;
Vdovenko, Marina M. .
TALANTA, 2013, 115 :414-417
[32]   Chemistry-Driven Approaches for Ultrasensitive Nucleic Acid Detection [J].
Smith, Sarah J. ;
Nemr, Carine R. ;
Kelley, Shana O. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2017, 139 (03) :1020-1028
[33]   Chemiluminescent microplate-based assay of DNA based on isothermal circular strand-displacement polymerization reaction (ICSDPR) [J].
Solovjev, Anton M. ;
Kurzeev, Sergei A. ;
Sakharov, Ivan Yu .
TALANTA, 2020, 215
[34]   Immobilized particle arrays: Coalescence of planar- and suspension-array technologies [J].
Stevens, PW ;
Wang, CHJ ;
Kelso, DM .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1141-1146
[35]   Application of magnetic nanoparticles in nucleic acid detection [J].
Tang, Congli ;
He, Ziyu ;
Liu, Hongmei ;
Xu, Yuyue ;
Huang, Hao ;
Yang, Gaojian ;
Xiao, Ziqi ;
Li, Song ;
Liu, Hongna ;
Deng, Yan ;
Chen, Zhu ;
Chen, Hui ;
He, Nongyue .
JOURNAL OF NANOBIOTECHNOLOGY, 2020, 18 (01)
[36]   Biosensing platform on ferrite magnetic nanoparticles: Synthesis, functionalization, mechanism and applications [J].
Tripathy, Ashis ;
Nine, Md Julker ;
Silva, Filipe Samuel .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2021, 290 (290)
[37]  
Vashist S.K., 2018, Handbook of Immunoassay Technologies, P455, DOI DOI 10.1016/B978-0-12-811762-0.00017-7
[38]   Adaption of a conventional ELISA to a 96-well ELISA-Array for measuring the antibody responses to influenza virus proteins and vaccines [J].
Waltari, Eric ;
Carabajal, Esteban ;
Sanyal, Mrinmoy ;
Friedland, Natalia ;
McCutcheon, Krista M. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2020, 481
[39]   Magnetic-fluorescent-targeting multifunctional aptasensorfor highly sensitive and one-step rapid detection of ochratoxin A [J].
Wang, Chengquan ;
Qian, Jing ;
Wang, Kan ;
Wang, Kun ;
Liu, Qian ;
Dong, Xiaoya ;
Wang, Chengke ;
Huang, Xingyi .
BIOSENSORS & BIOELECTRONICS, 2015, 68 :783-790
[40]   Recent advances on magnetic nanobead based biosensors: From separation to detection [J].
Wang, Lei ;
Lin, Jianhan .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 128