Treatment of in-stent restenosis with high speed rotational atherectomy and IVUS guidance in small <3.0 mm vessels

被引:0
作者
Schiele, F [1 ]
Meneveau, N [1 ]
Vuillemenot, A [1 ]
Gupta, S [1 ]
Bassand, JP [1 ]
机构
[1] Hop St Jacques, F-25030 Besancon, France
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1998年 / 44卷 / 01期
关键词
in-stent restenosis; rotational atherectomy; small vessels; intravascular ultrasound;
D O I
10.1002/(SICI)1097-0304(199805)44:1<77::AID-CCD19>3.0.CO;2-M
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The management of in-stent restenosis remains a subject for debate because no one revascularization option is considered the most appropriate. Since a high restenosis rate still occurs after repeat balloon angioplasty, new techniques are attempted in order to reduce this rate. A combination of high speed rotational atherectomy (HSRA) and adjunctive balloon angioplasty is likely to achieve good results. In small (<3.0 mm diameter) vessels, the risk of interaction between the burr and the stent increases, We thus used intravascular ultrasound (IVUS) guidance in the treatment of in-stent restenosis with HSRA in small <3.0 mm small diameter vessels. Nine patients with in-stent restenosis in small vessels were referred for repeat angioplasty. Initial IVUS examination was used to assess the minimal stent struts diameter and to guide the burr size selection. A combination of HSRA and additional balloon angioplasty was performed under IVUS and angiographic guidance. Mean angiographic reference diameter was 2.25 +/- 0.35 mm and mean stent struts diameter was 2.38 +/- 0.20 mm, Burr size was selected similar to 0.5 mm smaller than stent struts diameter and ranged from 1.75 to 2.5 mm, with a 0.88 +/- 0.12 mean burr/artery ratio (range 0.71, 1.08). In two patients, a second larger burr was used. In 4/9 patients, the burr size chosen under IVUS guidance was close to angiographic MLD at stent implantation and thus larger than what would be used without IVUS guidance, Additional balloon angioplasty was decided in all cases, using a 1.1 +/- 0.15 balloon/artery ratio, No complication occurred. Mean relative gain in minimal lumen diameter (MLD) was 94 +/- 90% after HSRA and 54 +/- 34% after balloon angioplasty (total relative gain 180 +/- 100%). IVUS guidance allowed safe management of in-stent restenosis in small vessels using combination of HSRA and balloon angioplasty. Long-term follow-up and comparison with other techniques are necessary to assess whether this technique should be used routinely. (C) 1998 Wiley-Liss, Inc.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 19 条
[1]  
Bottner RK, 1997, CATHETER CARDIO DIAG, V40, P144, DOI 10.1002/(SICI)1097-0304(199702)40:2<144::AID-CCD4>3.0.CO
[2]  
2-B
[3]  
BOWERMAN RE, 1991, CATHET CARDIOVASC DI, V34, P248
[4]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[5]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]   MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT [J].
GORDON, PC ;
GIBSON, CM ;
COHEN, DJ ;
CARROZZA, JP ;
KUNTZ, RE ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) :1166-1174
[7]   COMPARATIVE VALIDATION OF QUANTITATIVE CORONARY ANGIOGRAPHY SYSTEMS - RESULTS AND IMPLICATIONS FROM A MULTICENTER STUDY USING A STANDARDIZED APPROACH [J].
KEANE, D ;
HAASE, J ;
SLAGER, CJ ;
VANSWIJNDREGT, EM ;
LEHMANN, KG ;
OZAKI, Y ;
DIMARIO, C ;
KIRKEEIDE, R ;
SERRUYS, PW .
CIRCULATION, 1995, 91 (08) :2174-2183
[8]  
Klues HG, 1997, J AM COLL CARDIOL, V29, P7631
[9]   Safety and efficacy of angiography-guided stent placement in small native coronary arteries of <3.0 mm in diameter [J].
Lau, KW ;
He, Q ;
Ding, ZP ;
Johan, A .
CLINICAL CARDIOLOGY, 1997, 20 (08) :711-716
[10]   Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis [J].
Mehran, R ;
Mintz, GS ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06) :618-622