Left Versus Biventricular Assist Devices in Cardiac Arrest

被引:5
作者
Packer, Erik J. S. [1 ]
Slettom, Grete [1 ]
Solholm, Atle [1 ]
Mongstad, Arve [1 ]
Haaverstad, Rune [1 ,2 ]
Tuseth, Vegard [3 ]
Grong, Ketil [2 ]
Nordrehaug, Jan Erik [2 ]
机构
[1] Haukeland Hosp, Dept Heart Dis, Jonas Lies Vei 65, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Sci, Bergen, Norway
[3] Skansemyrsveien 18, Bergen, Norway
关键词
cardiac arrest; assist device; RVAD; LVAD; biventricular support; LEFT-VENTRICULAR ASSIST; PERCUTANEOUS CORONARY INTERVENTION; EXTRACORPOREAL MEMBRANE-OXYGENATION; CHEST COMPRESSION DEVICE; TIDAL CARBON-DIOXIDE; CARDIOPULMONARY-RESUSCITATION; CARDIOGENIC-SHOCK; LIFE-SUPPORT; PORCINE MODEL; MYOCARDIAL-INFARCTION;
D O I
10.1097/MAT.0000000000000694
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Maintaining adequate organ perfusion during cardiac arrest remains a challenge, and various assist techniques have been evaluated. We assessed whether a right ventricular impeller assist device (RVAD) in adjunct to a left ventricular impeller assist device (LVAD) is beneficial. Twenty anesthetized pigs were randomized to maximized circulatory support by percutaneously implanted left- or biventricular assist device(s) during 30 minutes of electrically induced ventricular fibrillation followed by three attempts of cardioversion. Continuous hemodynamic variables were recorded. Cardiac output and myocardial, cerebral, renal, and ileum mucosa tissue perfusion were measured with fluorescent microspheres, and repeated blood gas analyses were obtained. With biventricular support, an increased LVAD output was found compared with left ventricular (LV) support; 3.2 +/- 0.2 (SEM) vs. 2.0 +/- 0. 2L/minute just after start of ventricular fibrillation, 3.2 +/- 0.1 vs. 2.0 +/- 0.1L/minute after 15 minutes, and 3.0 +/- 0.1 vs. 2.1 +/- 0.1L/minute after 30 minutes of cardiac arrest (p(g) < 0.001). Biventricular support also increased aortic and LV pressure, in addition to end-tidal CO2. Tissue blood flow rates were increased for most organs with biventricular support. Blood gas analyses showed improved oxygenation and lower s-lactate values. However, myocardial perfusion was degraded with biventricular support and return of spontaneous circulation less frequent (5/10 vs. 10/10; p = 0.033). Biventricular support was associated with high intraventricular pressure and decreased myocardial perfusion pressure, correlating significantly with flow rates in the LV wall. A transmural flow gradient was observed for both support modes, with better maintained subepicardial than midmyocardial and subendocardial perfusion.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [21] Cardiac Issues in Cardiac Arrest
    Bougouin, Wulfran
    Cariou, Alain
    SEMINARS IN NEUROLOGY, 2017, 37 (01) : 13 - 18
  • [22] Usefulness of cardiac resynchronization therapy in the recovery of patients with left ventricular assist devices
    Verreault-Julien, Louis
    Philippon, Francois
    Charbonneau, Eric
    Kalavrouziotis, Dimitri
    LeRoux, Emilie
    Sarrazin, Jean-Francois
    Dubois, Michelle
    Voisine, Pierre
    Senechal, Mario
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 297 - 298
  • [23] Cardiopulmonary Resuscitation in Patients With Left Ventricular Assist Devices
    Vierecke, Juliane
    Defilippis, Ersilia M.
    Givertz, Michael M.
    JACC-HEART FAILURE, 2024, 12 (11) : 1931 - 1938
  • [24] Impact of Cardiac Resynchronization Therapy on Left Ventricular Unloading in Patients with Implanted Left Ventricular Assist Devices
    Tehrani, David M.
    Adatya, Sirtaz
    Grinstein, Jonathan
    Rodgers, Daniel
    Sarswat, Nitasha
    Kim, Gene H.
    Raikhelkar, Jayant
    Sayer, Gabriel
    Uriel, Nir
    ASAIO JOURNAL, 2019, 65 (02) : 117 - 121
  • [25] In-hospital cardiac arrest after STEMI: prevention strategies and post-arrest care
    Boyd, Walker
    Young, Wesley
    Yildiz, Mehmet
    Henry, Timothy D.
    Gorder, Kari
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2024, 22 (08) : 379 - 389
  • [26] Multimodal mechanical circulatory assist for perioperative biventricular failure
    Sugimura, Yukiharu
    Mehdiani, Arash
    Aubin, Hug
    Rellecke, Philipp
    Boeken, Udo
    Lichtenberg, Artur
    Akhyari, Payam
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (02) : 712 - 715
  • [27] Percutaneous left ventricular assist devices
    Kepka, Cezary
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2007, 3 (04): : 202 - 205
  • [28] CT of Left Ventricular Assist Devices
    Carr, Carrie M.
    Jacob, Jaisy
    Park, Soon J.
    Karon, Barry L.
    Williamson, Eric E.
    Araoz, Philip A.
    RADIOGRAPHICS, 2010, 30 (02) : 429 - 444
  • [29] Imaging of Left Ventricular Assist Devices
    Amin N.D.
    Little B.P.
    Henry T.S.
    Current Radiology Reports, 3 (9)
  • [30] External cardiac compression during cardiopulmonary resuscitation of patients with left ventricular assist devices
    Mabvuure, Nigel T.
    Rodrigues, Jeremy N.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (02) : 286 - 289