Intrinsic dual-energy processing of myocardial perfusion images

被引:0
作者
Brown, JK
Tang, HR
Hattner, RS
Bocher, M
Ratzlaff, NW
Kadkade, PP
Hasegawa, BH
Botvinick, EH
机构
[1] Univ Calif San Francisco, Nucl Med Sect, Div Cardiovasc, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Phys Res Lab, S San Francisco, CA USA
[3] Univ Calif San Francisco, Joint Bioengn Grad Grp, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
关键词
attenuation correction; myocardial perfusion; SPECT; (TI)-T-201;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a software-based method for processing dual-energy (TI)-T-201 SPECT emission projection data with the goal of calculating a spatially dependent index of the local impact of gamma-ray attenuation. We refer to this method as intrinsic dual-energy processing (IDEP). Methods: IDEP exploits the differential attenuation of lower energy emissions (69-83 keV) and higher energy emissions (167 keV) resulting from the decay of (TI)-T-201 to characterize the relative degree of low-energy gamma-ray attenuation throughout the myocardium. In particular, IDEP can be used to estimate the relative probability that a low-energy gamma-ray emitted from a particular region of the myocardium is detected during the acquisition of SPECT projection data. Studies on phantoms and healthy human Volunteers were performed to determine whether the IDEP method yielded detection probability images with systematic structure visible above the noise of these images and whether the systematic structure in the detection probability images could be rationalized physically. In patient studies, the relative regional detection probabilities were applied qualitatively to determine the likely effects of attenuation on the distribution of mapped photon emissions. Results: Measurements of the detection probability in uniform phantoms showed excellent agreement with those obtained from computer simulations for both 180 degrees and 360 degrees acquisitions. Additional simulations with digital phantoms showed good correlation between IDEP-estimated detection probabilities and calculated detection probabilities. In patient studies, the IDEP-derived detection probability maps showed qualitative agreement with known nonuniform attenuation characteristics of the human thorax. When IDEP data were integrated with the findings on the emission scan, the correlation with coronary anatomy (known in 6 patients and hypothesized on the basis of clinical and electrocardiographic parameters in 5 patients) was improved compared with evaluating the mapped emission image alone. Conclusion: The IDEP method has the potential to characterize the attenuation properties of an object without use of a separate transmission scan. Coupled with the emission data, it may aid coronary diagnosis.
引用
收藏
页码:1287 / 1297
页数:11
相关论文
共 50 条
  • [41] Rationale and design of the dual-energy computed tomography for ischemia determination compared to "gold standard" non-invasive and invasive techniques (DECIDE-Gold): A multicenter international efficacy diagnostic study of rest-stress dual-energy computed tomography angiography with perfusion
    Truong, Quynh A.
    Knaapen, Paul
    Pontone, Gianluca
    Andreini, Daniele
    Leipsic, Jonathon
    Carrascosa, Patricia
    Lu, Bin
    Branch, Kelley
    Raman, Subha
    Bloom, Stephen
    Min, James K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (05) : 1031 - 1040
  • [42] Extra-abdominal dual-energy CT applications: a comprehensive overview
    Cicero, Giuseppe
    Ascenti, Giorgio
    Albrecht, Moritz H.
    Blandino, Alfredo
    Cavallaro, Marco
    D'Angelo, Tommaso
    Carerj, Maria Ludovica
    Vogl, Thomas J.
    Mazziotti, Silvio
    RADIOLOGIA MEDICA, 2020, 125 (04): : 384 - 397
  • [43] PET/CT Myocardial Perfusion Imaging Acquisition and Processing: Ten Tips and Tricks to Help You Succeed
    Talal Alnabelsi
    Akanksha Thakkar
    Ahmed Ibrahim Ahmed
    Yushui Han
    Mouaz H. Al-Mallah
    Current Cardiology Reports, 2021, 23
  • [44] PET/CT Myocardial Perfusion Imaging Acquisition and Processing: Ten Tips and Tricks to Help You Succeed
    Alnabelsi, Talal
    Thakkar, Akanksha
    Ahmed, Ahmed Ibrahim
    Han, Yushui
    Al-Mallah, Mouaz H.
    CURRENT CARDIOLOGY REPORTS, 2021, 23 (05)
  • [45] Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH)
    Masy, Matthieu
    Giordano, Jessica
    Petyt, Gregory
    Hossein-Foucher, Claude
    Duhamel, Alain
    Kyheng, Maeva
    De Groote, Pascal
    Fertin, Marie
    Lamblin, Nicolas
    Bervar, Jean-Francois
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5100 - 5110
  • [46] Definition of Vascular Territories on Myocardial Perfusion Images by Integration with True Coronary Anatomy: A Hybrid PET/CT Analysis
    Javadi, Mehrbod S.
    Lautamaeki, Riikka
    Merrill, Jennifer
    Voicu, Corina
    Epley, William
    McBride, Gerald
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 198 - 203
  • [47] Perfusion vector-a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients
    Minarik, David
    Senneby, Martin
    Wollmer, Per
    Mansten, Alva
    Sjostrand, Karl
    Edenbrandt, Lars
    Tragardh, Elin
    EJNMMI RESEARCH, 2015, 5
  • [48] Impact of the dark rim artifact on quantification of myocardial perfusion and perfusion reserve from ssfp first pass images
    Raphael D Hazel
    Nathaniel Reichek
    Yi Wang
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [49] ANALYSIS OF GATED MYOCARDIAL PERFUSION SPECT IMAGES BASED ON COMPUTATIONAL IMAGE REGISTRATION
    Alves, Raquel S.
    Faria, Diogo Borges
    Costa, Durval Campos
    Tavares, Joao Manuel R. S.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [50] Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification
    Peter Kellman
    Michael S. Hansen
    Sonia Nielles-Vallespin
    Jannike Nickander
    Raquel Themudo
    Martin Ugander
    Hui Xue
    Journal of Cardiovascular Magnetic Resonance, 19