Assessment of left ventricular size and function by 3-dimensional transthoracic echocardiography: Impact of the echocardiography platform and analysis software

被引:7
作者
Castel, Anne Laure [1 ]
Toledano, Manuel [2 ]
Tribouilloy, Christophe [3 ,4 ]
Delelis, Francois [1 ]
Mailliet, Amandine [1 ]
Marotte, Nathalie [1 ]
Guerbaai, Raphaelle A. [5 ]
Levy, Franck [6 ]
Graux, Pierre [1 ]
Ennezat, Pierre-Vladimir [7 ]
Marechaux, Sylvestre [1 ,3 ]
机构
[1] Univ Catholique Lille, Univ Lille Nord France,GCS Grp Hop, Inst Catholique Lille,Lab Echocardiog, Serv Cardiol Nord,Ctr Valvulopathies,Fac Libre Me, Lille, France
[2] Univ Catholique Lille, Univ Lille Nord France, GCS Grp Hop, Inst Catholique Lille,Dept Imagerie Med, Lille, France
[3] CHU Amiens, Amiens, France
[4] Univ Picardie, Ctr Univ Rech Sante, Lab MP3CV, EA 7517, Amiens, France
[5] Univ Basel, Dept Publ Hlth, Fac Med, Basel, Switzerland
[6] Ctr Cardiothorac Monaco, Ave Ostende, Monaco, Monaco
[7] CHU Grenoble, Grenoble, France
关键词
EUROPEAN ASSOCIATION; CHAMBER QUANTIFICATION; EJECTION FRACTION; REFERENCE VALUES; VOLUMES; RECOMMENDATIONS; PERFORMANCE; VALIDATION; AGREEMENT; ALGORITHM;
D O I
10.1016/j.ahj.2018.05.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Whether echocardiography platform and analysis software impact left ventricular (LV) volumes, ejection fraction (EF), and stroke volume (SV) by transthoracic tridimensional echocardiography (3DE) has not yet been assessed. Hence, our aim was to compare 3DE LV end-diastolic and end-systolic volumes (EDV and ESV), LVEF, and SV obtained with echocardiography platform from 2 different manufacturers. Methods: 3DE was performed in 84 patients (65% of screened consecutive patients), with equipment from 2 different manufacturers, with subsequent off-line postprocessing to obtain parameters of LV function and size (Philips QLAB 3DQ and General Electric EchoPAC 4D autoLVQ). Twenty-five patients with clinical indication for cardiac magnetic resonance imaging served as a validation subgroup. Results: LVEDV and LVESV from 2 vendors were highly correlated (r=0.93), but compared with 4D autoLVQ, the use of Qlab 3DQ resulted in lower LVEDV and LVESV (bias: 11 mL, limits of agreement: -25 to + 47 and bias: 6 mL, limits of agreement: -22 to + 34, respectively). The agreement between LVEF values of each software was poor (intraclass correlation coefficient 0.62) despite no or minimal bias. SVs were also lower with Qlab 3DQ advanced compared with 4D autoLVQ, and both were poorly correlated (r=0.66). Consistently, the underestimation of LVEDV, LVESV, and SV by 3DE compared with cardiac magnetic resonance imaging was more pronounced with Philips QLAB 3DQ advanced than with 4D autoLVQ. Conclusions: The echocardiography platform and analysis software significantly affect the values of LV parameters obtained by 3DE. Intervendor standardization and improvements in 3DE modalities are needed to broaden the use of LV parameters obtained by 3DE in clinical practice. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 18 条
[1]   Reference values for left ventricular volumes with real-time 3-dimensional echocardiography [J].
Aune, Erlend ;
Baekkevar, Morten ;
Rodevand, Olaf ;
Otterstad, Jan Erik .
SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2010, 44 (01) :24-30
[2]   3D echocardiographic reference ranges for normal left ventricular volumes and strain: results from the EACVI NORRE study [J].
Bernard, Anne ;
Addetia, Karima ;
Dulgheru, Raluca ;
Caballero, Luis ;
Sugimoto, Tadafumi ;
Akhaladze, Natela ;
Athanassopoulos, George D. ;
Barone, Daniele ;
Baroni, Monica ;
Cardim, Nuno ;
Hagendorff, Andreas ;
Hristova, Krasimira ;
Ilardi, Federica ;
Lopez, Teresa ;
de la Morena, Gonzalo ;
Popescu, Bogdan A. ;
Penicka, Martin ;
Ozyigit, Tolga ;
Rodrigo Carbonero, Jose David ;
van de Veire, Nico ;
Von Bardeleben, Ralph Stephan ;
Vinereanu, Dragos ;
Zamorano, Jose Luis ;
Martinez, Christophe ;
Magne, Julien ;
Cosyns, Bernard ;
Donal, Erwan ;
Habib, Gilbert ;
Badano, Luigi P. ;
Lang, Roberto M. ;
Lancellotti, Patrizio .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (04) :475-483
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Reference Values for Real Time Three-Dimensional Echocardiography-Derived Left Ventricular Volumes and Ejection Fraction: Review and Meta-Analysis of Currently Available Studies [J].
Buccheri, Sergio ;
Costanzo, Luca ;
Tamburino, Corrado ;
Monte, Ines .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (12) :1841-1850
[5]   Normal Values of Real-Time 3-Dimensional Echocarcliographic Parameters in a Healthy Japanese Population - The JAMP-3D Study [J].
Fukuda, Shota ;
Watanabe, Hiroyuki ;
Daimon, Masao ;
Abe, Yukio ;
Hirashiki, Akihiro ;
Hirata, Kumiko ;
Ito, Hiroshi ;
Iwai-Takano, Masumi ;
Iwakura, Katsuomi ;
Izumi, Chisato ;
Hidaka, Takayuki ;
Yuasa, Toshinori ;
Murata, Kazuya ;
Nakatani, Satoshi ;
Negishi, Kazuaki ;
Nishigami, Kazuhiro ;
Nishikage, Tomoko ;
Ota, Takahiro ;
Hayashida, Akihiro ;
Sakata, Konomi ;
Tanaka, Nobuhiro ;
Yamada, Satoshi ;
Yamamoto, Kazuhiro ;
Yoshikawa, Junichi .
CIRCULATION JOURNAL, 2012, 76 (05) :1177-1181
[6]   Standardization of adult transthoracic echocardiography reporting in agreement with recent chamber quantification, diastolic function, and heart valve disease recommendations: an expert consensus document of the European Association of Cardiovascular Imaging [J].
Galderisi, Maurizio ;
Cosyns, Bernard ;
Edvardsen, Thor ;
Cardim, Nuno ;
Delgado, Victoria ;
Di Salvo, Giovanni ;
Donal, Erwan ;
Sade, Leyla Elif ;
Ernande, Laura ;
Garbi, Madalina ;
Grapsa, Julia ;
Hagendorff, Andreas ;
Kamp, Otto ;
Magne, Julien ;
Santoro, Ciro ;
Stefanidis, Alexandros ;
Lancellotti, Patrizio ;
Popescu, Bogdan ;
Habib, Gilbert .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (12) :1301-1310
[7]   Recommendations of the European Association of Echocardiography How to use echo-Doppler in clinical trials: different modalities for different purposes [J].
Galderisi, Maurizio ;
Henein, Michael Y. ;
D'hooge, Jan ;
Sicari, Rosa ;
Badano, Luigi P. ;
Luis Zamorano, Jose ;
Roelandt, Jos R. T. C. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (05) :339-353
[8]   Three dimensional echocardiography: approaches and clinical utility [J].
Johri, Amer M. ;
Passeri, Jonathan J. ;
Picard, Michael H. .
HEART, 2010, 96 (05) :390-397
[9]   Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Mor-Avi, Victor ;
Afilalo, Jonathan ;
Armstrong, Anderson ;
Ernande, Laura ;
Flachskampf, Frank A. ;
Foster, Elyse ;
Goldstein, Steven A. ;
Kuznetsova, Tatiana ;
Lancellotti, Patrizio ;
Muraru, Denisa ;
Picard, Michael H. ;
Rietzschel, Ernst R. ;
Rudski, Lawrence ;
Spencer, Kirk T. ;
Tsang, Wendy ;
Voigt, Jens-Uwe .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (01) :1-U170
[10]   Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Mor-Avi, Victor ;
Afilalo, Jonathan ;
Armstrong, Anderson ;
Ernande, Laura ;
Flachskampf, Frank A. ;
Foster, Elyse ;
Goldstein, Steven A. ;
Kuznetsova, Tatiana ;
Lancellotti, Patrizio ;
Muraru, Denisa ;
Picard, Michael H. ;
Rietzschel, Ernst R. ;
Rudski, Lawrence ;
Spencer, Kirk T. ;
Tsang, Wendy ;
Voigt, Jens-Uwe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (03) :233-271