Determination of vitamin B12 in multivitamin tablets and fermentation medium by high-performance liquid chromatography with fluorescence detection

被引:67
作者
Li, HB [1 ]
Chen, F [1 ]
Jiang, Y [1 ]
机构
[1] Univ Hong Kong, Dept Bot, Hong Kong, Hong Kong, Peoples R China
关键词
pharmaceutical analysis; vitamins;
D O I
10.1016/S0021-9673(00)00724-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method for the determination of vitamin B-12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B-12 was analyzed by HPLC on a mu Bondapak C-18 column (300X3.9 mm, 10 mu m) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 With a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B-12 in vitamin B-12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:243 / 247
页数:5
相关论文