Haemodynamic responses following orotracheal intubation in patients with hypertension-Macintosh direct laryngoscope versus Glidescope®videolaryngoscope

被引:10
|
作者
Meshram, Tanvi M. [1 ]
Ramachandran, Rashmi [1 ]
Trikha, Anjan [1 ]
Rewari, Vimi [1 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Anaesthesiol Pain Med & Crit Care, New Delhi, India
关键词
Glidescope; haemodynamic response; intubation; Macintosh laryngoscope; CERVICAL-SPINE; GLIDESCOPE(R); VIDEOLARYNGOSCOPE;
D O I
10.4103/ija.IJA_417_20
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Glidescope (R) videolaryngoscope (GVL) is a video intubation system with 60 degrees angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope (R) videolaryngoscope (GVL) in hypertensive patients. Methods: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. Results: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. Conclusion: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [41] GlideScope® cobalt video laryngoscope versus direct Miller laryngoscope for lateral position-tracheal intubation in neonates with myelodysplasia: A prospective randomized study
    Salama, Eman Ramadan
    El Amrousy, Doaa
    SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (01) : 28 - 34
  • [42] Comparative evaluation of glidescope videolaryngosocope and conventional macintosh laryngoscope for nasotracheal intubation in patients undergoing oropharyngeal cancer surgeries: A prospective randomized study
    Kumar, Abhishek
    Gupta, Nishkarsh
    Kumar, Vinod
    Bharti, Sachidanand Jee
    Garg, Rakesh
    Kumar, Rajeev
    Bhatnagar, Sushma
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (04) : 542 - 547
  • [43] A comparison of intubating conditions for nasotracheal intubation with standard direct Macintosh laryngoscope versus C-MAC® video laryngoscope employing cuff inflation technique in adult patients
    Kasaudhan, Sonia
    Gupta, Madhu
    Singh, Kriti
    Khan, Anas
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (15) : 104 - 109
  • [44] Comparison of the incidence of postoperative sore throat between patients undergoing videolaryngoscope-guided versus Macintosh laryngoscope-guided double-lumen intubation: a systematic review and meta-analysis
    Yu, Yayi
    Liu, Ying
    Zhong, Wu
    SIGNA VITAE, 2023, 19 (01) : 148 - 156
  • [45] Comparison of the McGrath videolaryngoscope and the Macintosh laryngoscope for double lumen endobronchial tube intubation in patients with manual in-line stabilization: A randomized controlled trial
    Yoo, Ji Young
    Park, Sung Yong
    Kim, Jong Yeop
    Kim, Myungseob
    Haam, Seok Jin
    Kim, Dae Hee
    MEDICINE, 2018, 97 (10)
  • [46] Macintosh laryngoscope vs. Pentax-AWS video laryngoscope: comparison of efficacy and cardiovascular responses to tracheal intubation in major burn patients
    Woo, Chul-Ho
    Kim, Sung Hoon
    Park, Jae-Young
    Bae, Ji Young
    Kwak, In-Suk
    Mun, Sung Ha
    Kim, Kwang-Min
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (02) : 119 - 124
  • [47] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Hyesun Paik
    Hee-Pyoung Park
    BMC Anesthesiology, 20
  • [48] Shikani Optical Stylet versus Macintosh Laryngoscope for Intubation in Patients Undergoing Surgery for Cervical Spondylosis: A Randomized Controlled Trial
    Xu Mao
    Li Xiao-Xi
    Guo Xiang-Yang
    Wang Jun
    中华医学杂志英文版, 2017, 130 (03) : 297 - 302
  • [49] Shikani Optical Stylet versus Macintosh Laryngoscope for Intubation in Patients Undergoing Surgery for Cervical Spondylosis: A Randomized Controlled Trial
    Xu, Mao
    Li, Xiao-Xi
    Guo, Xiang-Yang
    Wang, Jun
    CHINESE MEDICAL JOURNAL, 2017, 130 (03) : 297 - 302
  • [50] A prospective randomized controlled study to evaluate and compare GlideScope with Macintosh laryngoscope for ease of endotracheal intubation in adult patients undergoing elective surgery under general anesthesia
    Jafra, Anudeep
    Gombar, Satinder
    Kapoor, Dheeraj
    Sandhu, Harpreet Singh
    Kumari, Kamlesh
    SAUDI JOURNAL OF ANAESTHESIA, 2018, 12 (02) : 272 - 278