On the Beat Detection Performance in Long-Term ECG Monitoring Scenarios

被引:12
|
作者
Melgarejo-Meseguer, Francisco-Manuel [1 ]
Everss-Villalba, Estrella [1 ]
Gimeno-Blanes, Francisco-Javier [2 ]
Blanco-Velasco, Manuel [3 ]
Molins-Bordallo, Zaida [1 ]
Flores-Yepes, Jose-Antonio [2 ]
Rojo-Alvarez, Jose-Luis [4 ,5 ]
Garcia-Alberola, Arcadi [1 ]
机构
[1] Hosp Gen Univ Virgen Arrixaca, Cardiol Serv, Arrhythmia Unit, Murcia 30120, Spain
[2] Miguel Hernandez Univ, Dept Signal Theory & Commun, Alicante 03202, Spain
[3] Univ Alcala, Dept Signal Theory & Commun, Madrid 28805, Spain
[4] Univ Politecn Madrid, Ctr Computat Simulat, Madrid 28223, Spain
[5] Rey Juan Carlos Univ, Dept Signal Theory & Commun, Madrid 28943, Spain
关键词
QRS detection; ECG; long-term monitoring; Holter; 7-day; QRS DETECTION; ATRIAL-FIBRILLATION; CATHETER ABLATION; RECOGNITION; COMPLEX; CLASSIFICATION; COMPONENTS; TRANSFORM; ALGORITHM;
D O I
10.3390/s18051387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Despite the wide literature on R-wave detection algorithms for ECG Holter recordings, the long-term monitoring applications are bringing new requirements, and it is not clear that the existing methods can be straightforwardly used in those scenarios. Our aim in this work was twofold: First, we scrutinized the scope and limitations of existing methods for Holter monitoring when moving to long-term monitoring; Second, we proposed and benchmarked a beat detection method with adequate accuracy and usefulness in long-term scenarios. A longitudinal study was made with the most widely used waveform analysis algorithms, which allowed us to tune the free parameters of the required blocks, and a transversal study analyzed how these parameters change when moving to different databases. With all the above, the extension to long-term monitoring in a database of 7-day Holter monitoring was proposed and analyzed, by using an optimized simultaneous-multilead processing. We considered both own and public databases. In this new scenario, the noise-avoid mechanisms are more important due to the amount of noise that exists in these recordings, moreover, the computational efficiency is a key parameter in order to export the algorithm to the clinical practice. The method based on a Polling function outperformed the others in terms of accuracy and computational efficiency, yielding 99.48% sensitivity, 99.54% specificity, 99.69% positive predictive value, 99.46% accuracy, and 0.85% error for MIT-BIH arrhythmia database. We conclude that the method can be used in long-term Holter monitoring systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] LONG-TERM AMBULATORY ECG MONITORING FOR OPTIMIZING ANTIISCHEMIC THERAPY
    LEVIN, RI
    KELLER, B
    CAMPBELL, DQ
    CIRCULATION, 1986, 74 (04) : 190 - 190
  • [22] LONG-TERM ECG MONITORING TO ASSESS VENTRICULAR ECTOPIC ACTIVITY
    STEIN, IM
    LEE, AF
    CIRCULATION, 1979, 59 (04) : 843 - 844
  • [23] Medical-Grade ECG Sensor for Long-Term Monitoring
    Rashkovska, Aleksandra
    Depolli, Matjaz
    Tomasic, Ivan
    Avbelj, Viktor
    Trobec, Roman
    SENSORS, 2020, 20 (06)
  • [24] Long-Term ECG Monitoring with Zeroing Compressed Sensing Approach
    Mangia, M.
    Bortolotti, D.
    Bartolini, A.
    Pareschi, F.
    Benini, L.
    Rovatti, R.
    Setti, G.
    2015 NORDIC CIRCUITS AND SYSTEMS CONFERENCE (NORCAS) - NORCHIP & INTERNATIONAL SYMPOSIUM ON SYSTEM-ON-CHIP (SOC), 2015,
  • [25] Long-term ECG monitoring in patients after ischaemic stroke
    Jansky, P.
    Bulkova, V.
    Znamenackova, K.
    Valentova, K.
    Kunesova, V.
    Tomek, A.
    Mikulik, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2023, 30 : 199 - 199
  • [26] Flexible polymeric dry electrodes for the long-term monitoring of ECG
    Baek, Ju-Yeoul
    An, Jin-Hee
    Choi, Jong-Min
    Park, Kwang-Suk
    Lee, Sang-Hoon
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) : 423 - 429
  • [27] An Open-Access Long-Term Wearable ECG Database for Premature Ventricular Contractions and Supraventricular Premature Beat Detection
    Cai, Zhipeng
    Liu, Chengyu
    Gao, Hongxiang
    Wang, Xingyao
    Zhao, Lina
    Shen, Qin
    Ng, E. Y. K.
    Li, Jianqing
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (11) : 2663 - 2667
  • [28] Visual saliency detection approach for long-term ECG analysis
    Mukhopadhyay, Sourav Kumar
    Krishnan, Sridhar
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 213
  • [29] Long-term performance cover systems-verification and long-term monitoring
    Boutwell Jr., Gordon P.
    Clarke, James H.
    Dunn, R. Jeffrey
    Kuppusamy, Thangavelu
    Reddi, Lakshmi N.
    Trudell, Mark R.
    Velzy, Charles O.
    Center for Research and Technology Development, (Publication) CRTD, American Society of Mechanical Engineers, 2002, 61 : 375 - 382
  • [30] Atrial fibrillation detection algorithms for very long term ECG monitoring
    Petrucci, E
    Balian, V
    Filippini, G
    Mainardi, LT
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 623 - 626