A two-detector single-crystal scintillation autocorrelation spectrometer with rejection of afterpulses

被引:2
|
作者
Morozov, VA [1 ]
Morozova, NV [1 ]
机构
[1] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
关键词
Physical Chemistry; Autocorrelation; Coincidence Method; Delay Coincidence Method;
D O I
10.1023/A:1022523021051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A two-detector single-crystal scintillation autocorrelation spectrometer with rejection of afterpulses has been developed. Afterpulses are rejected by the delayed coincidence method.
引用
收藏
页码:32 / 34
页数:3
相关论文
共 50 条
  • [21] AN EFFICIENT SINGLE-CRYSTAL BSE DETECTOR IN SEM
    AUTRATA, R
    HERMANN, R
    MULLER, M
    SCANNING, 1992, 14 (03) : 127 - 135
  • [22] SCINTILLATION ACTIVITY IN AN UNIRRADIATED SINGLE-CRYSTAL OF 3-HYDROXYXANTHINE
    COOKE, DW
    JAHAN, MS
    ALEXANDER, C
    HEALTH PHYSICS, 1976, 31 (05): : 465 - 467
  • [23] Response of a single-crystal diamond detector to fast neutrons
    Rebai, M.
    Milocco, A.
    Giacomelli, L.
    Cippo, E. Perelli
    Tardocchi, M.
    Fazzi, A.
    Pietropaolo, A.
    Gorini, G.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [24] SUMMATION OF GAMMA-RAY ENERGIES WITH A SINGLE-CRYSTAL SPECTROMETER
    LU, DC
    WIEDENBECK, ML
    PHYSICAL REVIEW, 1954, 94 (02): : 501 - 502
  • [25] SCANNING SINGLE-CRYSTAL MULTICHANNEL X-RAY SPECTROMETER
    SPIELBERG, N
    LADELL, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1963, 34 (11): : 1208 - &
  • [26] DETECTION OF 2.5-MEV NEUTRONS WITH A SINGLE-CRYSTAL SCINTILLATION COUNTER
    SEGEL, RE
    SWARTZ, CD
    OWEN, GE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (02): : 140 - 144
  • [27] CALCULATION OF THE DIAMETER OF A RADIATION-OPTICAL CONVERTER OF A SCINTILLATION SINGLE-CRYSTAL
    LEONOV, BI
    SOSNIN, FR
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1978, 14 (08): : 725 - 728
  • [28] Development of a position-sensitive scintillation neutron detector for a new protein single-crystal diffractometer at J-PARC MLF
    Nakamura, T.
    Toh, K.
    Tsutsui, N.
    Ebine, M.
    Birumachi, A.
    Sakasai, K.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [29] An Investigation of Single-Crystal PbTe for Nuclear Radiation Detector Applications
    Kim, Geehyun
    Hammig, Mark D.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1732 - 1737
  • [30] Pixelated Single-crystal Diamond Detector for fast neutron measurements
    Rebai, M.
    Cazzaniga, C.
    Croci, G.
    Tardocchi, M.
    Cippo, E. Perelli
    Calvani, P.
    Girolami, M.
    Trucchi, D. M.
    Grosso, G.
    Gorini, G.
    JOURNAL OF INSTRUMENTATION, 2015, 10