Variable-gradient generator for micro- and nano-HPLC

被引:35
作者
Cappiello, A [1 ]
Famiglini, G [1 ]
Florucci, C [1 ]
Mangani, F [1 ]
Palma, P [1 ]
Siviero, A [1 ]
机构
[1] Univ Urbino, Ist Sci Chim F Bruner, Urbino, Italy
关键词
D O I
10.1021/ac026125z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple device generates accurate nano- and microflow rate gradients from any conventional HPLC system. The core of the new device is represented by an electric-actuated, computer-controlled, multiposition HPLC valve. The valve hosts six reservoirs for as many different mobile-phase compositions of increasing strength. A low flow rate stream pushes the weakest solvent through the column as long as required and at the desired flow rate, until the chromatographic run is started. From this time on, the electric actuation allows one to select which reservoir will be on-line with the column and for how long, thus generating a specific solvent gradient, through a sequence of controlled segments of precise mobile-phase composition. This permits one not only to exactly reproduce the programmed slope but also to achieve different gradient shapes (i.e., linear, convex, concave) for different separation needs. The new device has proven to be reliable and reproducible even at the lowest flow rate tested (250 nL.min(-1)) and in different chromatographic conditions.
引用
收藏
页码:1173 / 1179
页数:7
相关论文
共 20 条
[11]   STUDY OF MICRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DEVELOPMENT OF TECHNIQUE FOR MINIATURIZATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ISHII, D ;
ASAI, K ;
HIBI, K ;
JONOKUCHI, T ;
NAGAYA, M .
JOURNAL OF CHROMATOGRAPHY, 1977, 144 (02) :157-168
[12]  
JINNO K, 1989, LC GC-MAG SEP SCI, V7, P328
[13]   THE EVOLUTION OF CAPILLARY COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
JINNO, K .
CHROMATOGRAPHIA, 1988, 25 (11) :1004-1011
[14]   Nanoflow gradient generator coupled with μ-LC-ESI- MS/MS for protein identification [J].
Le Bihan, T ;
Pinto, D ;
Figeys, D .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1307-1315
[15]   GRADIENT SEPARATIONS OF COMPLEX-MIXTURES BY MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (06) :310-315
[16]   APPLICATION OF ULTRAMICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TO TRACE ANALYSIS [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :199-208
[17]   CONTINUOUS GRADIENT ELUTION IN MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1982, 253 (01) :41-47
[18]   Microcolumn liquid chromatography: Instrumentation, detection and applications [J].
Vissers, JPC ;
Claessens, HA ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :1-28
[19]   Recent developments in microcolumn liquid chromatography [J].
Vissers, JPC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :117-143
[20]  
Zhang ZQ, 1998, HRC-J HIGH RES CHROM, V21, P291