Flexible alpha camera for detecting plutonium contamination

被引:15
作者
Morishita, Yuki [1 ]
Yamamoto, Seiichi [2 ]
Izaki, Kenji [1 ]
Kaneko, Junichi H. [3 ]
Nemoto, Norio [1 ]
机构
[1] Japan Atom Energy Agcy, 4-33 Muramatsu, Tokai, Ibaraki, Japan
[2] Nagoya Univ, Grad Sch Med, Higashi Ku, 1-1-20 Daiko Minami, Nagoya, Aichi, Japan
[3] Hokkaido Univ, Grad Sch Engn, Kita Ku, Kita 13,Nishi 8, Sapporo, Hokkaido 0608628, Japan
关键词
Plutonium contamination; Alpha particle; Silicon photomultiplier; Narrow space; Glovebox; PET; SIPM;
D O I
10.1016/j.radmeas.2017.04.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We developed a new imaging detector called flexible alpha camera that can identify Pu contamination in narrow spaces at work sites. The thickness of the flexible alpha camera is only similar to 1/5th that of the ZnS(Ag) scintillation detector which is commonly used for detecting Pu contamination, and its efficiency in the 4 pi direction is 42.7% for 5.5-MeV alpha particles. The minimal detectable activity (MDA) is 0.014 Bq measured in 30 min. Four types of PuO2 samples, taken from a duct, bag-in/bag-out port, glovebox glove, and vinyl sheet, were measured by the flexible alpha camera. In a two-dimensional distribution of alpha particles, PuO2 was identified automatically using the "AnalyzeParticle" function in the ImageJ plugin, and its activity was evaluated. When acquisition time increased from 10 min to 30 min, a Pu spot with low activity was identified. To verify the measurement in narrow space, a fume hood to which a PuO2 particle was attached was measured using the flexible alpha camera. Since the flexible alpha camera has the thin-thickness of 12 mm and can obtain two-dimensional distribution and energy spectrum of alpha particles, it is effective for detecting Pu contamination in narrow spaces of equipment. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 1995, RAD HLTH SER, V38
[2]  
[Anonymous], 2014, WASTE MANAG
[3]  
Bebington Aaron M., 2007, THESIS
[4]  
Cournoyer M. E., 2005, WM 05 C
[5]  
Cournoyer M. E., 2004, WM 04 C
[6]   Microscopic analysis of glovebox glove failures and breaches [J].
Cournoyer, Michael E. ;
Trujillo, Stanley ;
Blask, Cynthia L. .
JOURNAL OF CHEMICAL HEALTH & SAFETY, 2012, 19 (05) :39-46
[7]   Performance of FBK high-density SiPM technology coupled to Ce:LYSO and Ce:GAGG for TOF-PET [J].
Ferri, Alessandro ;
Gola, Alberto ;
Serra, Nicola ;
Tarolli, Alessandro ;
Zorzi, Nicola ;
Piemonte, Claudio .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04) :869-880
[8]   CONTAMINATION CONTROL OF PLUTONIUM-241 BY MEASUREMENT OF LOW ENERGY BETA RADIATION [J].
GALE, HJ ;
PEAPLE, LHJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1963, 8 (1-4) :297-&
[9]   AUTORADIOGRAPHY - TECHNIQUE FOR DRASTIC REDUCTION OF EXPOSURE TIME TO ALPHA PARTICLES [J].
HSIEH, JJC ;
HUNGATE, FP ;
WILSON, SA .
SCIENCE, 1965, 150 (3705) :1821-&
[10]  
Iida T., 1983, NUCL INSTRUM METHODS, V212, P413