An Analysis of a Quasi-One-Dimensional Structure Fabricated by Low-Energy Focused Ion Beam

被引:0
|
作者
Chantngarm, Peerasak [1 ]
机构
[1] Pathumwan Inst Technol, Dept Elect & Telecommun Engn, Bangkok 10330, Thailand
来源
TENCON 2009 - 2009 IEEE REGION 10 CONFERENCE, VOLS 1-4 | 2009年
关键词
focused ion beam; quasi-one-dimensional structure; resistivity; residue damages; size effects;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The resistivity of a quasi-one-dimensional structure fabricated without masks by 20-keV Ga+ focused ion beam (FIB) on crystalline Si substrates was investigated for the first time, along with an analysis of properties of implanted p+ layers. The junction depth of the 7 degrees off-axis implanted layer after annealing, which was measured by stain method, is 410 nm. The distribution profile was investigated by SIMS, which showed channeling effects. The Hall mobility is 131 cm2/V-sec. This is 61% of the ideal value, which might be caused by residual defects. The resistance of the quasi-one-dimensional structure is 1.1x109 Omega, which is 647 times higher than the projected value. The cause of this phenomenon is considered to be the combined effects of interfacial roughness, the residue damages, the size effects and also the shape effects of the structure.
引用
收藏
页码:995 / 998
页数:4
相关论文
共 28 条
  • [21] Three-dimensional GaN nano-structure fabrication by focused ion beam chemical vapor deposition
    Nagata, T
    Ahmet, P
    Yamauchi, Y
    Sakuma, Y
    Sekiguchi, T
    Chikyow, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 242 (1-2): : 250 - 252
  • [22] 3-DIMENSIONAL ANALYSIS OF INORGANIC MICROCAPSULES BY SUBMICRON SIMS USING A GALLIUM FOCUSED ION-BEAM
    TOMIYASU, B
    SATOH, H
    OWARI, M
    NIHEI, Y
    BUNSEKI KAGAKU, 1991, 40 (11) : 629 - 633
  • [23] Three-dimensional ultrastructural analysis and histomorphometry of collagen bundles in the periodontal ligament using focused ion beam/scanning electron microscope tomography
    Hirashima, Shingo
    Ohta, Keisuke
    Kanazawa, Tomonoshin
    Okayama, Satoko
    Togo, Akinobu
    Miyazono, Yoshihiro
    Kusukawa, Jingo
    Nakamura, Kei-ichiro
    JOURNAL OF PERIODONTAL RESEARCH, 2020, 55 (01) : 23 - 31
  • [24] Focused ion beam sample preparation, transmission electron microscopy and electron energy loss spectroscopy analysis of advanced CMOS silicon technology interconnections
    Pantel, R
    Auvert, G
    Mascarin, G
    MICROELECTRONIC ENGINEERING, 1997, 37-8 (1-4) : 49 - 57
  • [25] Low-temperature thermopower and phonon-drag effect in the quasi-one-dimensional cobaltate Ba3Co2O6(CO3)0.7
    Komatsu, Asuka
    Sato, Yoshiki J.
    Yoshida, Shogo
    Okazaki, Ryuji
    Kurihara, Ryosuke
    Yaguchi, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (11)
  • [26] Structure and physical properties of Ni-based quasi-one-dimensional selenides Rb0.9Ni3.1Se3 and K0.7Ni3.1Se3
    Lin, Jiawei
    Deng, Jun
    Guo, Zhongnan
    Cheng, Erjian
    Sun, Fan
    Liu, Ning
    Wang, Bianbian
    Li, Shiyan
    Yuan, Wenxia
    JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 793 : 425 - 432
  • [27] Three-dimensional pore structure characterization of cement paste by X-ray computed tomography (XCT) and focused ion beam/scanning electron microscopy (FIB/SEM)
    Jiang, Zhilu
    Pan, Yingjie
    Fu, Chuanqing
    Li, Weiwen
    Wang, Yaocheng
    Long, Wu-Jian
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 383
  • [28] Maskless selective direct growth and doping of GaAs using a Ga-Sn low energy focused ion beam for in-situ micro-device structures fabrication
    Cho, DH
    Suzuki, Y
    Tanaka, M
    Hachiro, M
    Pak, K
    JOURNAL OF CRYSTAL GROWTH, 2002, 237 : 1455 - 1459