Acoustic radiation force impulse with shear wave speed quantification of pancreatic masses: A prospective study

被引:22
|
作者
D'Onofrio, Mirko [1 ]
De Robertis, Riccardo [1 ]
Crosara, Stefano [1 ]
Poli, Cristina [1 ]
Canestrini, Stefano [1 ]
Demozzi, Emanuele [1 ]
Mucelli, Roberto Pozzi [1 ]
机构
[1] Univ Verona, GB Rossi Hosp, Dept Radiol, Piazzale LA Scuro 10, I-37134 Verona, Italy
关键词
Elastography Pancreatic adenocarcinoma; Pancreatic cystic tumors; Pancreatic cancer; Ultrasonography; Acoustic Radiation Force Impulse (ARFI); IN-VIVO; NONINVASIVE ASSESSMENT; CYSTIC LESIONS; ARFI; ELASTOGRAPHY; DIAGNOSIS; LIVER; ULTRASONOGRAPHY; STIFFNESS; MODULUS;
D O I
10.1016/j.pan.2015.12.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Acoustic Radiation Force Impulse (ARFI) is a new ultrasound technique that evaluates mechanical properties of tissues. To evaluate the use of ARFI with shear waves speed quantification for pancreatic masses characterization during the ultrasound examination. Methods: 123 pancreatic lesions were prospectively evaluated. Median shear waves speeds were compared with Mann Whitney U test. Two reading methods were applied for the characterization of adenocarcinoma: more than one measurement above the top shear waves speed (SWS) value. Two reading methods were applied to diagnose mucinous lesion: at least 2 (method 1) or 3 (method 2) numerical measurements. Sensitivity, specificity, positive and negative predictive values and accuracy of each reading method were calculated. Forty volunteers were included for normal ARFI values. Results: In the adenocarcinoma group median SWS value was 2.74 m/s. In the volunteers group the median SWS value was 1.17 m/s. Significant difference between SWS median values of adenocarcinoma and normal pancreas was found (P < 0.05). For the diagnosis of pancreatic solid masses if more than one measurement is above the top SWS value of 4.00 m/s results in the study, the diagnosis of ductal adenocarcinoma is highly specific with specificity and PPV of 100%. Good sensitivity (73.3%) and specificity (83.3%) were obtained for the characterization of mucinous cystic lesions. Conclusions: Acoustic Radiation Force Impulse imaging could help in the non-invasive characterization of solid and cystic lesions of the pancreas during a conventional US examination. Copyright (C) 2015, IAP and EPC. Published by Elsevier India, a division of Reed Elsevier India Pvt. Ltd. All rights reserved.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 50 条
  • [1] Role of acoustic radiation force impulse and shear wave velocity in prediction of preterm birth: a prospective study
    Agarwal, Arjit
    Agarwal, Shubhra
    Chandak, Shruti
    ACTA RADIOLOGICA, 2018, 59 (06) : 755 - 762
  • [2] Shear Wave Velocities of various Pancreatic Disorders of Acoustic Radiation Force Impulse (ARFI) Elastometry
    Goertz, R.
    Schuderer, J.
    Wildner, D.
    Neurath, M.
    Strobel, D.
    INTERNIST, 2015, 56 : 33 - 33
  • [3] Acoustic radiation force impulse imaging with Virtual Touch (TM) tissue quantification: mean shear wave velocity of malignant and benign breast masses
    Wojcinski, Sebastian
    Brandhorst, Kathrin
    Sadigh, Gelareh
    Hillemanns, Peter
    Degenhardt, Friedrich
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2013, 5 : 619 - 627
  • [4] Acoustic radiation force impulse shear wave elastography (ARFI) of acute and chronic pancreatitis and pancreatic tumor
    Goertz, Ruediger S.
    Schuderer, Johanna
    Strobel, Deike
    Pfeifer, Lukas
    Neurath, Markus F.
    Wildner, Dane
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2211 - 2216
  • [5] A Rational Arrangement of Measuring Shear Wave Speed in the Liver Evoked By Acoustic Radiation Force Impulse.
    Yokoo, Takeshi
    Kanefuji, Tsutomu
    Suda, Takeshi
    Kimura, Naruhiro
    Setsu, Toru
    Kamimura, Hiroteru
    Sakamaki, Akira
    Kamimura, Kenya
    Tsuchiya, Atsunori
    Takamura, Masaaki
    Yamagiwa, Satoshi
    Terai, Shuji
    HEPATOLOGY, 2018, 68 : 624A - 624A
  • [6] Diagnostic Performance of Point Shear Wave Elastography (pSWE) Using Acoustic Radiation Force Impulse (ARFI) Technology in Mesenteric Masses: A Feasibility Study
    Alhyari, Amjad
    Goerg, Christian
    Dietrich, Christoph Frank
    Kawohl, Svenja
    Safai Zadeh, Ehsan
    DIAGNOSTICS, 2022, 12 (02)
  • [7] Evaluation of Pancreatic Fibrosis With Acoustic Radiation Force Impulse Imaging and Automated Quantification of Pancreatic Tissue Components
    Fujita, Yusuke
    Kitago, Minoru
    Abe, Tokiya
    Itano, Osamu
    Shinoda, Masahiro
    Abe, Yuta
    Yagi, Hiroshi
    Hibi, Taizo
    Ishii, Masatsugu
    Nakano, Yutaka
    Okuma, Kiyoshi
    Hashimoto, Masahiro
    Takeuchi, Ayano
    Masugi, Yohei
    Jinzaki, Masahiro
    Sakamoto, Michiie
    Kitagawa, Yuko
    PANCREAS, 2018, 47 (10) : 1277 - 1282
  • [8] Acoustic Radiation Force Impulse imaging of in vivo breast masses
    Sharma, AC
    Soo, MS
    Trahey, GE
    Nightingale, KR
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 728 - 731
  • [9] Reproducibility of Shear Wave Velocity Measurements by Acoustic Radiation Force Impulse Imaging of the Liver A Study in Healthy Volunteers
    Guzman-Aroca, Florentina
    Reus, Manuel
    Berna-Serna, Juan D.
    Serrano, Laura
    Serrano, Cristina
    Gilabert, Amparo
    Cepero, Angela
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (07) : 975 - 979
  • [10] FACTORS THAT INFLUENCE KIDNEY SHEAR WAVE SPEED ASSESSED BY ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY IN PATIENTS WITHOUT KIDNEY PATHOLOGY
    Bota, Simona
    Bob, Flaviu
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 1 - 6