Characterization of hyperechoic focal liver lesions -: Quantitative evaluation with pulse inversion harmonic imaging in the late phase of Levovist

被引:10
|
作者
Celik, H [1 ]
Özdemir, H [1 ]
Yücel, C [1 ]
Gultekin, S [1 ]
Oktar, SO [1 ]
Arac, M [1 ]
机构
[1] Gazi Univ, Sch Med, Dept Radiol, TR-06510 Ankara, Turkey
关键词
contrast media; hyperechoic liver tumors; pulse inversion harmonic imaging; ultrasonography;
D O I
10.7863/jum.2005.24.1.39
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The aim of this study was to evaluate hyperechoic focal liver lesions with pulse inversion harmonic imaging in the late phase of SH U 508A (Levovist, Schering AG, Berlin, Germany) and to determine whether quantitative evaluation improves the characterization of the lesions. Methods. Twenty-six patients with hyperechoic liver lesions were enrolled in this study. Pulse inversion harmonic imaging was performed before and after administration of Levovist. Scan data were digitally stored, and each lesion was analyzed with a personal computer-based quantification package. All lesions were confirmed by histologic or triphasic spiral computed tomographic examinations. The intensity was measured in decibels in regions of interest drawn within the lesion and surrounding liver parenchyma. The lesion-liver ratios were than calculated. After contrast agent administration, a ratio equal to or greater than I was presumed benign, whereas a ratio of less than I was considered malignant. Results. Nine malignant (7 metastases, 1 hepatocellular carcinoma, and 1 cholangiocarcinoma) and 17 benign (14 hemangioma, 1 focal nodular hyperplasia, 1 focal fatty change, and 1 inflammatory pseudotumor) hyperechoic lesions were quantitatively evaluated. All malignant (n = 9) and 2 benign lesions (I hemangioma and I inflammatory pseudotumor) had ratios of less than 1. In 15 of 17 benign lesions, the ratios were equal to or greater than 1. The intensity ratios calculated for benign and malignant lesions showed a statistically significant difference (P < .05). Conclusions. Pulse inversion harmonic imaging with quantitative evaluation facilitates the differential diagnosis of hyperechoic focal liver lesions. A lesion-liver ratio equal to or greater than I predicts a benign nature, assuming that malignant lesions show a ratio of less than 1.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [31] Pulse inversion harmonic imaging: A comparison to fundamental and tissue harmonic imaging in evaluation of gallbladder
    Hong, HS
    Han, JK
    Kim, TK
    Kim, JS
    Kim, YH
    Choi, BI
    RADIOLOGY, 1999, 213P : 147 - 147
  • [32] Comparing Levovist-Enhanced pulse inversion harmonic imaging and ferumoxides-enhanced MR imaging of hepatic metastases
    Del Frate, C
    Zuiani, C
    Londero, V
    Como, G
    Bazzocchi, M
    Mortele, K
    Pablo, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (05) : 1339 - 1346
  • [33] Clinical evaluation of harmonic imaging in the sonographic differential diagnosis of focal liver lesions, a prospective study on 101 liver lesions.
    Strobel, D
    Raeker, S
    Martus, P
    Hahn, E
    Becker, D
    HEPATOLOGY, 2000, 32 (04) : 230A - 230A
  • [34] Contrast-enhanced pulse inversion imaging of the liver with a perfluorocarbon agent: Protocols for the differential diagnosis of focal lesions
    Burns, PN
    Wilson, SR
    Kahlili, K
    RADIOLOGY, 2000, 217 : 458 - 459
  • [35] Clinical, Imaging and Anatomopathological Characterization of Focal Liver Lesions
    Fonte Grinan, Emma Midiannys
    Misas Menendez, Maribel
    Gonzalez Santana, Ileana
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2014, 12 (02): : 390 - 397
  • [36] Detection of liver metastases with pulse inversion harmonic imaging: Preliminary results
    Dalla-Palma, L
    Bertolotto, M
    Quaia, E
    Locatelli, M
    EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) : S382 - S387
  • [37] Detection of liver metastases with pulse inversion harmonic imaging: Preliminary results
    L. Dalla Palma
    M. Bertolotto
    E. Quaia
    M. Locatelli
    European Radiology, 1999, 9 : S382 - S387
  • [38] Diagnostic accuracy of phase-inversion tissue harmonic imaging versus fundamental B-mode sonography in the evaluation of focal lesions of the kidney
    Schmidt, T
    Hohl, C
    Haage, P
    Blaum, M
    Honnef, D
    Weiss, C
    Staatz, G
    Günther, RW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) : 1639 - 1647
  • [39] Characterization of focal liver lesions: Value of Color and Power Doppler evaluation pre and post intravenous injection of the ultrasound contrast agent levovist
    Strunk, HM
    Textor, J
    Hortling, N
    Schild, HH
    RADIOLOGY, 1997, 205 : 829 - 829
  • [40] Improved detection of liver metastases with phase inversion imaging during the liver-specific phase of the ultrasound contrast agent Levovist
    Albrecht, T
    Hoffmann, CW
    Schettler, S
    Overberg, A
    Ilg, M
    Wolf, KJ
    EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) : S388 - S388