Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode

被引:50
作者
Alamo, Lori Shayne T. [1 ,2 ]
Tangkuaram, Tanin [1 ]
Satienperakul, Sakchai [1 ]
机构
[1] Maejo Univ, Fac Sci, Dept Chem, Chiang Mai 50290, Thailand
[2] Nueva Vizcaya State Univ, Dept Chem, Coll Arts & Sci, Bayombong 3700, Nueva Vizcaya, Philippines
关键词
Sulfite; Flow injection; Pervaporation; Copper hexacyanoferrate-carbon nanotube modified carbon paste electrode; FILM-MODIFIED ELECTRODES; FREE SULFUR-DIOXIDE; COBALT-HEXACYANOFERRATE; GAS-DIFFUSION; ELECTROCATALYTIC OXIDATION; CHROMIUM HEXACYANOFERRATE; ELECTROCHEMICAL SENSOR; SEQUENTIAL INJECTION; WINE; BIOSENSORS;
D O I
10.1016/j.talanta.2010.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pervaporation-flow injection (PFI) method was developed for the determination of sulfite in selected food samples using a copper hexacyanoferrate-carbon nanotube (CuHCF-CNT)-modified carbon paste electrode The electrochemical behavior of the modified electrode was observed using cyclic voltammetry in comparison to a CuHCF-modified carbon paste electrode and a bare carbon paste electrode at a scan rate of 100 mVs(-1) in 0 10 M KNO3. The bare carbon paste electrode gave the lowest response to sulfite, while the presence of CuHCF made the detection of sulfite possible through electrocatalytic oxidation by the hexacyanoferrate in the modified electrodes The presence of CNT in the CuHCF-CNT-modified sensor gave the most remarkable current for the detection of sulfite and was then used as a working electrode in the amperometric flow-through cell in the pervaporation flow injection system The PFI method involves the injection of a standard or sample sulfite solution into a sulfuric acid donor stream to generate sulfur dioxide gas and evaporate into the headspace of the pervaporation unit. The sulfur dioxide diffuses through the PTFE hydrophobic membrane Into a potassium nitrate acceptor stream and reverts to the sulfite form, which, subsequently, is transported to the electrochemical flow cell where it is analyzed amperometrically at a CuHCF-CNT-modified electrode at +055 V (vs. Ag/AgCl) The detection was determined to be applicable in the sulfite concentration range of 0.5-50 mg L-1. The sensitivity, detection limit. and sample throughput were determined to be 2.105 nA L mg(-1), 0.40 mg L-1 and 11 h(-1). respectively. The developed PFI method. coupled with the CuHCF-CNT-modified carbon paste electrode. was applied in the determination of sulfite content in sulfite-containing food products The results agreed well with those obtained through the officially recommended differential pulse polarographic method. (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:1793 / 1799
页数:7
相关论文
共 43 条
  • [1] Electrocatalytic oxidation of L-cysteine with a stable copper-cobalt hexacyanoferrate electrochemically modified carbon paste electrode
    Abbaspour, A.
    Ghaffarinejad, A.
    [J]. ELECTROCHIMICA ACTA, 2008, 53 (22) : 6643 - 6650
  • [2] Design and characteristics of a sulfide and sulfite optode based on immobilization of methyl violet on a triacetylcellulose membrane
    Afkhami, Abbas
    Arlak, Nahid S.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) : 285 - 289
  • [3] Role of carbon nanotubes in electroanalytical chemistry -: A review
    Agui, Lourdes
    Yanez-Sedeno, Paloma
    Pingarron, Jose M.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) : 11 - 47
  • [4] *AOAC INC, 1990, OFF METH AN ASS OFF
  • [5] Copper hexacyanoferrate nanoparticles modified electrodes: A versatile tool for biosensors
    Baioni, Ana P.
    Vidotti, Marcio
    Fiorito, Pablo A.
    de Toressi, Susana I. Cordoba
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 622 (02) : 219 - 224
  • [6] Carbon nanotube electrode for oxidation of dopamine
    Britto, PJ
    Santhanam, KSV
    Ajayan, PM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01): : 121 - 125
  • [7] Determination of sulfite by flow injection analysis using a poly [Ni-(protoporphyrin IX)] chemically modified electrode
    Carballo, R
    Dall'Orto, VC
    Lo Balbo, A
    Rezzano, I
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) : 155 - 161
  • [8] Preparation, characterization, and electrocatalytic properties of copper hexacyanoferrate film and bilayer film modified electrodes
    Chen, SM
    Chan, CM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 543 (02) : 161 - 173
  • [9] Amperometric determination of sulfite by gas diffusion-sequential injection with boron-doped diamond electrode
    Chinvongamorn, Chakorn
    Pinwattana, Kulwadee
    Praphairaksit, Narong
    Imato, Toshihiko
    Chailapakul, Orawon
    [J]. SENSORS, 2008, 8 (03) : 1846 - 1857
  • [10] Electrochemical sensor for sulfite determination based on a nanostructured copper-salen film modified electrode
    Dadamos, Tony R. L.
    Teixeira, Marcos F. S.
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (19) : 4552 - 4558