Excitation emission matrix fluorescence spectroscopy for combustion generated particulate matter source identification

被引:17
|
作者
Rutherford, Jay W. [1 ]
Dawson-Elli, Neal [1 ]
Manicone, Anne M. [5 ]
Korshin, Gregory V. [2 ]
Novosselov, Igor V. [2 ]
Seto, Edmund [4 ]
Posner, Jonathan D. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Chem Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Family Med, Seattle, WA 98195 USA
[4] Univ Washington, Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
[5] Univ Washington, Dept Med Pulm Crit Care & Sleep Med, Seattle, WA 98195 USA
关键词
Fluorescence; Source apportionment; Particulate matter; Diesel; Woodsmoke; Neural network; POLYCYCLIC AROMATIC-HYDROCARBONS; NEURAL-NETWORKS; ORGANIC-MATTER; DEPOSITION; PM;
D O I
10.1016/j.atmosenv.2019.117065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The inhalation of particulate matter (PM) is a significant health risk associated with reduced life expectancy due to increased cardio-pulmonary disease and exacerbation of respiratory diseases such as asthma and pneumonia. PM originates from natural and anthropogenic sources including combustion engines, cigarettes, agricultural burning, and forest fires. Identifying the source of PM can inform effective mitigation strategies and policies, but this is difficult to do using current techniques. Here we present a method for identifying PM source using excitation emission matrix (EEM) fluorescence spectroscopy and a machine learning algorithm. We collected combustion generated PM2.5 from wood burning, diesel exhaust, and cigarettes using filters. Filters were weighted to determine mass concentration followed by extraction into cyclohexane and analysis by EEM fluorescence spectroscopy. Spectra obtained from each source served as training data for a convolutional neural network (CNN) used for source identification in mixed samples. This method can predict the presence or absence of the three laboratory sources with an overall accuracy of 89% when the threshold for classifying a source as present is 1.1 mu g/m(3) in air over a 24-h sampling time. The limit of detection for cigarette, diesel and wood are 0.7, 2.6, 0.9 mu g/m(3), respectively, in air assuming a 24-h sampling time at an air sampling rate of 1.8 L per minute. We applied the CNN algorithm developed using the laboratory training data to a small set of field samples and found the algorithm was effective in some cases but would require a training data set containing more samples to be more broadly applicable.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The power of fluorescence excitation-emission matrix (EEM) spectroscopy in the identification and characterization of complex mixtures of fluorescent silver clusters
    Ramsay, H.
    Simon, D.
    Steele, E.
    Hebert, A.
    Oleschuk, R. D.
    Stamplecoskie, K. G.
    RSC ADVANCES, 2018, 8 (73): : 42080 - 42086
  • [32] Identification of lu'an Guapian at different picking periods by using excitation-emission matrix fluorescence spectroscopy coupled with chemometrics
    Ren, Hang
    Lin, Lin-Li
    Dong, Ming-Yue
    Yin, Xiao-Yue
    Wang, Tong
    Wu, Hai-Long
    Yu, Ru-Qin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 328
  • [33] Identification of resistance in Escherichia coli and Klebsiella pneumoniae using excitation-emission matrix fluorescence spectroscopy and multivariate analysis
    Costa, Fernanda S. L.
    Bezerra, Caio C. R.
    Neto, Renato M.
    Morais, Camilo L. M.
    Lima, Kassio M. G.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [34] Particulate matter emission in agricultural biomass residue combustion
    Nugraha, M. G.
    Sharfan, A.
    Prakoso, V. S. Y.
    Hidayat, M.
    Saptoadi, H.
    GLOBAL JOURNAL OF ENVIRONMENTAL SCIENCE AND MANAGEMENT-GJESM, 2024, 10 (03): : 1047 - 1066
  • [35] Fluorescence excitation - Emission matrix regional integration to quantify spectra for dissolved organic matter
    Chen, W
    Westerhoff, P
    Leenheer, JA
    Booksh, K
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (24) : 5701 - 5710
  • [36] Analysis of polarity fractionated dissolved organic matter using 3-D fluorescence excitation-emission matrix spectroscopy
    Rosario-Ortiz, Fernando L.
    Snyder, Shane
    Suffet, I. H.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 444 - 444
  • [37] New advances in fluorescence excitation-emission matrix spectroscopy for the characterization of dissolved organic matter in drinking water treatment: A review
    Li, Lei
    Wang, Yang
    Zhang, Wenjun
    Yu, Shuili
    Wang, Xianyun
    Gao, Naiyun
    CHEMICAL ENGINEERING JOURNAL, 2020, 381 (381)
  • [38] Evaluating Soil Dissolved Organic Matter Extraction Using Three-Dimensional Excitation-Emission Matrix Fluorescence Spectroscopy
    Xie Wenming
    Zhang Shanshan
    Ruan Lin
    Yang Mingyue
    Shi Weiming
    Zhang Hailin
    Li Weihua
    PEDOSPHERE, 2017, 27 (05) : 968 - 973
  • [39] Parallel Factor Analysis for Excitation Emission Matrix Fluorescence Spectroscopy of Dissolved Organic Matter from a Reservoir-Type River
    Guo Wei-dong
    Yang Li-yang
    Wang Fu-li
    Chen Wen-zhao
    Wang Xin-hong
    Hong Hua-sheng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (02) : 427 - 430
  • [40] Study on Optical Characteristics of Chromophoric Dissolved Organic Matter (CDOM) In Rainwater by Fluorescence Excitation-Emission Matrix and Absorbance Spectroscopy
    Cheng Yuan-yue
    Guo Wei-dong
    Long Ai-min
    Chen Shao-yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (09) : 2413 - 2416