Validating cone-beam computed tomography for peri-implant bone morphometric analysis

被引:29
|
作者
Huang, Yan [1 ,2 ,3 ]
Van Dessel, Jeroen [1 ,2 ]
Depypere, Maarten [4 ]
EzEldeen, Mostafa [1 ,2 ]
Iliescu, Alexandru Andrei [5 ]
Dos Santos, Emanuela [6 ]
Lambrichts, Ivo [7 ]
Liang, Xin [8 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Leuven, Belgium
[3] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China
[4] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium
[5] UMF Craiova, Fac Dent, Craiova, Romania
[6] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil
[7] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium
[8] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China
来源
BONE RESEARCH | 2014年 / 2卷
关键词
TRABECULAR BONE; CT; OSTEOPOROSIS; ARCHITECTURE; MICROSTRUCTURE; STANDARD; BIOPSIES;
D O I
10.1038/boneres.2014.10
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Morphometric Analysis of Mandibular Trabecular Bone Using Cone Beam Computed Tomography: An In Vitro Study
    Naitoh, Munetaka
    Aimiya, Hidetoshi
    Hirukawa, Akiko
    Ariji, Eiichiro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1093 - 1098
  • [32] The Effect of Implant-Induced Artifacts on Interpreting Adjacent Bone Structures on Cone-Beam Computed Tomography Scans
    Sheridan, Rachel A.
    Chiang, Yi-Chen
    Decker, Ann M.
    Sutthiboonyapan, Pimchanok
    Chan, Hsun-Liang
    Wang, Hom-Lay
    IMPLANT DENTISTRY, 2018, 27 (01) : 10 - 14
  • [33] Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
    de Carvalho Crusoe Silva, Isabela Maria
    de Freitas, Deborah Queiroz
    Bovi Ambrosano, Glaucia Maria
    Boscolo, Frab Norberto
    Almeida, Solange Maria
    BRAZILIAN ORAL RESEARCH, 2012, 26 (06): : 550 - 556
  • [34] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [35] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) : 3S - 6S
  • [36] Intraoperative Evaluation of Cochlear Implant Electrodes Using Mobile Cone-Beam Computed Tomography
    Yamamoto, Norio
    Okano, Takayuki
    Yamazaki, Hiroshi
    Hiraumi, Harukazu
    Sakamoto, Tatsunori
    Ito, Juichi
    Omori, Koichi
    OTOLOGY & NEUROTOLOGY, 2019, 40 (02) : 177 - 183
  • [37] Morphometric analysis of vidian canal and its relations with surrounding anatomic structures by using cone-beam computed tomography
    Kurt, M. H.
    Bozkurt, P.
    Bilecenoglu, B.
    Kolsuz, M. E.
    Orhan, K.
    FOLIA MORPHOLOGICA, 2020, 79 (02) : 366 - 373
  • [38] Cone-Beam Computed Tomography (CBCT)-Based Diagnosis of Dental Bone Defects
    Alshomrani, Faisal
    DIAGNOSTICS, 2024, 14 (13)
  • [39] Computed gray levels in multislice and cone-beam computed tomography
    Azeredo, Fabiane
    de Menezes, Luciane Macedo
    Enciso, Reyes
    Weissheimer, Andre
    de Oliveira, Rogerio Belle
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) : 147 - 155
  • [40] Multichannel Computed Tomography Versus Cone-Beam Computed Tomography: Linear Accuracy of In Vitro Measurements of the Maxilla for Implant Placement
    Fatemitabar, Seyed Ahmad
    Nikgoo, Arash
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 499 - 505