Validating cone-beam computed tomography for peri-implant bone morphometric analysis

被引:29
|
作者
Huang, Yan [1 ,2 ,3 ]
Van Dessel, Jeroen [1 ,2 ]
Depypere, Maarten [4 ]
EzEldeen, Mostafa [1 ,2 ]
Iliescu, Alexandru Andrei [5 ]
Dos Santos, Emanuela [6 ]
Lambrichts, Ivo [7 ]
Liang, Xin [8 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Leuven, Belgium
[3] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China
[4] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium
[5] UMF Craiova, Fac Dent, Craiova, Romania
[6] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil
[7] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium
[8] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China
来源
BONE RESEARCH | 2014年 / 2卷
关键词
TRABECULAR BONE; CT; OSTEOPOROSIS; ARCHITECTURE; MICROSTRUCTURE; STANDARD; BIOPSIES;
D O I
10.1038/boneres.2014.10
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY
    Andrade, Marcos E. A.
    Khoury, Helen J.
    Nascimento Neto, Joao B. S.
    Kramer, Richard
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 175 - 180
  • [22] Mandible Bone Osteoporosis Detection using Cone-beam Computed Tomography
    Abu Marar, Rasha F.
    Uliyan, Diaa M.
    Al-Sewadi, Hamza A.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2020, 10 (04) : 6027 - 6033
  • [23] Cone-Beam Computed Tomography: A New Method for Imaging of the Temporal Bone
    Peltonen, L. I.
    Aarnisalo, A. A.
    Kaser, Y.
    Kortesniemi, M. K.
    Robinson, S.
    Suomalainen, A.
    Jero, J.
    ACTA RADIOLOGICA, 2009, 50 (05) : 543 - 548
  • [24] Morphometric Analysis of Sella Turcica Using Cone-Beam Computed Tomography in Patients With Cleft Lip and Palate
    Yalcin, Eda Didem
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (01) : 306 - 309
  • [25] Considerations in the use of cone-beam computed tomography for buccal bone measurements
    Molen, Aaron Dean
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S130 - S135
  • [26] Cone-beam computed tomography performance in measuring periodontal bone loss
    Yang, Jingmei
    Li, Xinyi
    Duan, Dingyu
    Bai, Lin
    Zhao, Lei
    Xu, Yi
    JOURNAL OF ORAL SCIENCE, 2019, 61 (01) : 61 - 66
  • [27] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [28] Investigation of the morphometric features of bony nasolacrimal canal: a cone-beam computed tomography study
    Okumus, O.
    FOLIA MORPHOLOGICA, 2020, 79 (03) : 588 - 593
  • [29] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [30] Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery
    Husain, Adib Al-Haj
    Mergen, Victor
    Valdec, Silvio
    Husain, Nadin Al-Haj
    Stadlinger, Bernd
    Essig, Harald
    Frauenfelder, Thomas
    Kessler, Peter
    Lie, Suen An Nynke
    Alkadhi, Hatem
    Winklhofer, Sebastian
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)