Validating cone-beam computed tomography for peri-implant bone morphometric analysis

被引:29
|
作者
Huang, Yan [1 ,2 ,3 ]
Van Dessel, Jeroen [1 ,2 ]
Depypere, Maarten [4 ]
EzEldeen, Mostafa [1 ,2 ]
Iliescu, Alexandru Andrei [5 ]
Dos Santos, Emanuela [6 ]
Lambrichts, Ivo [7 ]
Liang, Xin [8 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Leuven, Belgium
[3] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China
[4] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium
[5] UMF Craiova, Fac Dent, Craiova, Romania
[6] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil
[7] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium
[8] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China
来源
BONE RESEARCH | 2014年 / 2卷
关键词
TRABECULAR BONE; CT; OSTEOPOROSIS; ARCHITECTURE; MICROSTRUCTURE; STANDARD; BIOPSIES;
D O I
10.1038/boneres.2014.10
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [2] Influence of Peri-implant Artifacts on Bone Morphometric Analysis with Micro-computed Tomography
    Song, Jin Wook
    Cha, Jung Yul
    Bechtold, Till Edward
    Park, Young Chel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 519 - 525
  • [3] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [4] A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects
    Dave, Meetal
    Davies, Jonathan
    Wilson, Ron
    Palmer, Richard
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) : 671 - 678
  • [5] Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs
    Hedayatipanah, Morad
    Salemi, Fatemeh
    Kamyari, Naser
    Yalpanian, Ashkan
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
  • [6] Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    Fienitz, Tim
    Schwarz, Frank
    Ritter, Lutz
    Dreiseidler, Timo
    Becker, Juergen
    Rothamel, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 882 - 887
  • [7] Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity
    Hohlweg-Majert, B.
    Metzger, M. C.
    Kummer, T.
    Schulze, D.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2011, 39 (05) : 330 - 334
  • [8] Higher Resolution in Cone Beam Computed Tomography Is Accompanied by Improved Bone Detection in Peri-implant Bone Despite Metal Artifact Presence
    Kerkfeld, Valentin
    Meyer, Ulrich
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1331 - 1338
  • [9] The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis
    Suttapreyasri, Srisurang
    Suapear, Pradipat
    Leepong, Narit
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2026 - 2031
  • [10] Morphometric study of the greater palatine canal: cone-beam computed tomography
    Rapado-Gonzalez, O.
    Suarez-Quintanilla, J. A.
    Otero-Cepeda, X. L.
    Fernandez-Alonso, A.
    Suarez-Cunqueiro, M. M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2015, 37 (10) : 1217 - 1224