Bio-compatible wireless inductive thin-film strain sensor for monitoring the growth and strain response of bone in osseointegrated prostheses

被引:15
作者
Burton, Andrew R. [1 ]
Sun, Peng [1 ]
Lynch, Jerome P. [1 ,2 ]
机构
[1] Univ Michigan, Dept Civil & Environm Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2021年 / 20卷 / 03期
关键词
Thin film; wireless induction; strain sensor; bone-growth monitoring; structural health monitoring; osseointegrated prosthetics; photolithography; AMPUTATION; INTERFACE; IMPLANT; DESIGN;
D O I
10.1177/1475921719831452
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many benefits can be derived from in situ monitoring of the growth, load response, and condition of human bone. In particular, bone monitoring offers opportunity to advance understanding and designing of osseointegrated mechanical components fixated into bones such as artificial joints and more recently osseointegrated prosthetic limbs. In this study, a bio-compatible wireless inductive strain-sensing system is proposed, which is designed to monitor the growth and strain response of bone-hosting implants. Thin-film circuit fabrication methods based on lithography are adopted to develop a conformable wireless strain sensor designed as a passive resistive-inductive-capacitive circuit. Two forms of strain sensing are designed into the thin-film sensor. First, parallel-plate capacitors fabricated from metal electrodes and a polyimide dielectric layer are introduced to modulate bone strain onto a resonant frequency of the thin-film sensor. A second resonant frequency is introduced in the sensor design to measure circumferential bone growth using a highly nonlinear titanium-resistive element, whose resistance exponentially increases well after 1000 mu epsilon under monotonic increasing hoop strain. To ensure the possibility for implantation in animal subjects in future study, the thin-film sensing system is fabricated using mainly bio-compatible polymers (e.g. polyimide) and metals (e.g. titanium and gold). Fabricated prototypes inductively coupled using an impedance analyzer are experimentally tested. Results reveal linear response of the first resonant frequency to low levels of strain with a sensitivity of 4.555 Hz per unit microstrain. The second resonant frequency is sensitive to the resistive fuse with nonlinear fuse behavior initiated above 1000 mu epsilon and impedance phase increasing exponentially thereafter.
引用
收藏
页码:749 / 767
页数:19
相关论文
共 33 条
[1]   Osteoinduction, osteoconduction and osseointegration [J].
Albrektsson, T ;
Johansson, C .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S96-S101
[2]  
[Anonymous], 1997, INT J ORAL MAXILLOFA
[3]  
[Anonymous], 2002, MICROSYSTEMS H PI 25
[4]  
Branemark P., 2006, The Biomaterials: Silver Jubilee CompendiumAnonymous, P17
[5]   Concept, design and fabrication of smart orthopedic implants [J].
Burny, F ;
Donkerwolcke, M ;
Moulart, F ;
Bourgois, R ;
Puers, R ;
Van Schuylenbergh, K ;
Barbosa, M ;
Paiva, O ;
Rodes, F ;
Bégueret, JB ;
Lawes, P .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) :469-479
[6]   Wireless Passive RFID Crack Width Sensor for Structural Health Monitoring [J].
Caizzone, Stefano ;
DiGiampaolo, Emidio .
IEEE SENSORS JOURNAL, 2015, 15 (12) :6767-6774
[7]   Passive Wireless Frequency Doubling Antenna Sensor for Strain and Crack Sensing [J].
Cho, Chunhee ;
Yi, Xiaohua ;
Li, Dan ;
Wang, Yang ;
Tentzeris, Manos M. .
IEEE SENSORS JOURNAL, 2016, 16 (14) :5725-5733
[8]  
Demann Eric T K, 2005, J Long Term Eff Med Implants, V15, P687
[9]  
Dhert WJA, 1998, J BIOMED MATER RES, V41, P574, DOI 10.1002/(SICI)1097-4636(19980915)41:4<574::AID-JBM9>3.3.CO
[10]  
2-E