Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes

被引:85
作者
Allen, PM [1 ]
Radhakrishnan, H [1 ]
O'Leary, DJ [1 ]
机构
[1] Anglia Polytech Univ, Dept Optometry & Ophthalm Dispensing, Cambridge CB1 1PT, England
关键词
autorefractor; photorefraction; powerrefractor; validity; repeatability;
D O I
10.1097/00006324-200303000-00014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We assessed the repeatability and validity of the PowerRefractor and the Nidek AR-600A autorefractor. This is the first independent study conducted on adults to evaluate the performance of these instruments in a laboratory setting. Fifty subjects (23 males and 27 females) aged 16 to 61 years (mean, 37 +/- 12) participated in the study. The validity of the PowerRefractor and the Nidek autorefractor readings were determined by comparing them to subjective refraction. Measurements of refractive error were obtained from the two instruments on two separate occasions to assess their repeatability. The measured refractive error was converted into a dioptric power matrix for data analysis. No significant difference was found between the measurements obtained with the two instruments and the subjective refraction. The estimate of refractive error given by the two instruments was also found to be repeatable. In addition to measuring the refractive error, the PowerRefractor also offers the facility to measure eye position, pupil size, and dynamics of accommodation. We suggest some improvements to the PowerRefractor measurement technique to standardize its clinical use and to improve accuracy.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 14 条
  • [1] Angi M R, 1993, Ger J Ophthalmol, V2, P182
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor)
    Choi, M
    Weiss, S
    Schaeffel, F
    Seidemann, A
    Howland, HC
    Wilhelm, B
    Wilhelm, H
    [J]. OPTOMETRY AND VISION SCIENCE, 2000, 77 (10) : 537 - 548
  • [4] DUKEELDER S, 1968, PHYSL EYE VISION, P415
  • [5] Repeatability and accuracy of automated refraction: A comparison of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction
    Elliott, M
    Simpson, T
    Richter, D
    Fonn, D
    [J]. OPTOMETRY AND VISION SCIENCE, 1997, 74 (06) : 434 - 438
  • [6] Measurement of astigmatism by automated infrared photoretinoscopy
    Gekeler, F
    Schaeffel, F
    Howland, HC
    WattamBell, J
    [J]. OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) : 472 - 482
  • [7] HARRIS WF, 1989, OPHTHAL PHYSL OPT, V9, P455, DOI 10.1111/j.1475-1313.1989.tb00952.x
  • [8] Harris WF., 1989, The South African Optometrist, V48, P81
  • [9] HUMPHRISS D, 1962, Br J Physiol Opt, V19, P15
  • [10] KEATING MP, 1986, AM J OPTOM PHYS OPT, V63, P830