The effect of time on mechanical properties of biocompatible photopolymer resins used for fabrication of clear dental aligners

被引:32
作者
Milovanovic, Aleksa [1 ]
Sedmak, Aleksandar [2 ]
Golubovic, Zorana [2 ]
Mihajlovic, Ksenija Zelic [3 ]
Zurkic, Aleksandar [4 ,5 ]
Trajkovic, Isaak [1 ]
Milosevic, Milos [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Innovat Ctr, Belgrade, Serbia
[2] Univ Belgrade, Fac Mech Engn, Belgrade, Serbia
[3] Univ Belgrade, Sch Med, Inst Anat, Lab Anthropol Belgrade, Belgrade, Serbia
[4] Shimadzu Co Ltd, Kyoto, Japan
[5] Branch Belgrade, Belgrade, Serbia
关键词
Time Effect; Additive manufacturing; Biocompatible polymers; Dental aligners; Mechanical properties; THERMOPLASTIC MATERIALS; TOOTH MOVEMENT; IMPACT; RESTORATIONS; COMPOSITES;
D O I
10.1016/j.jmbbm.2021.104494
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clear dental aligners are used for treating orthodontic anomalies (misaligned teeth, inappropriate contact between upper and lower teeth etc.), minor irregularities and bruxism. Using additive manufacturing technologies clear dental aligners are made of biocompatible photopolymer, using a vat photopolymerization technology. One of problems in application is the change of aligner material properties after production, including strength and elongation at failure. This can cause different sequence of tooth displacement which will not correspond to the planned therapy. In this paper three types of material testing are conducted i.e., tensile, compressive and threepoint bending testing on specimens of 1 (24 h), 3 (72 h), 5 (120 h) and 7 (168 h) days old. Mechanical properties, such as tensile, compressive and flexural strength and strain at failure are monitored in order to show the effect of time on biocompatible photopolymer resin.
引用
收藏
页数:9
相关论文
共 49 条
[1]  
[Anonymous], 2009, 16412009 BS EN
[2]  
[Anonymous], 2017, 6042002 ISO
[3]  
[Anonymous], 2019, Plastics-Determination of Flexural Properties
[4]  
[Anonymous], 2012, ISO 527-2, DOI DOI 10.31030/1860304
[5]  
ASTM, 2013, F279212A ASTM INT
[6]  
Boyd R.e., 2001, SEMIN ORTHOD, V7, P274, DOI DOI 10.1053/SODO.2001.25414
[7]   Predicted and actual end-of-treatment occlusion produced with aligner therapy [J].
Buschang, Peter H. ;
Ross, Mike ;
Shaw, Steven G. ;
Crosby, Doug ;
Campbell, Phillip M. .
ANGLE ORTHODONTIST, 2015, 85 (05) :723-727
[8]   3D-Printed Chips: Compatibility of Additive Manufacturing Photopolymeric Substrata with Biological Applications [J].
Carve, Megan ;
Wlodkowic, Donald .
MICROMACHINES, 2018, 9 (02)
[9]  
Chantarapanich N., 2013, SONGKLA J SCI TECHNO, V35, P91
[10]   The impact of personality on adult patients' adjustability to orthodontic appliances [J].
Cooper-Kazaz, Rena ;
Ivgi, Inbal ;
Canetti, Laura ;
Bachar, Eytan ;
Tsur, Boaz ;
Chaushu, Stella ;
Shalish, Miriam .
ANGLE ORTHODONTIST, 2013, 83 (01) :76-82