Three-dimensional measurement and visualization of internal flow of a moving droplet using confocal micro-PIV

被引:227
作者
Kinoshita, Haruyuki [1 ]
Kaneda, Shohei [1 ]
Fujii, Teruo [1 ]
Oshima, Marie [1 ]
机构
[1] Univ Tokyo, Inst Ind Sci, Meguro Ku, Tokyo, Japan
关键词
D O I
10.1039/b617391h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a micro-flow diagnostic technique, 'high-speed confocal micro-particle image velocimetry (PIV)', and its application to the internal flow measurement of a droplet passing through a microchannel. A confocal micro-PIV system has been successfully constructed wherein a high-speed confocal scanner is combined with the conventional micro-PIV technique. The confocal micro-PIV system enables us to obtain a sequence of sharp and high-contrast cross-sectional particle images at 2000 frames s(-1). This study investigates the confocal depth, which is a significant parameter to determine the out-of-plane measurement resolution in confocal micro-PIV. Using the present confocal micro-PIV system, we can measure velocity distributions of micro-flows in a 228 mm 6 171 mu m region with a confocal depth of 1.88 mu m. We also propose a three-dimensional velocity measurement method based on the confocal micro-PIV and the equation of continuity. This method enables us to measure three velocity components in a three-dimensional domain of micro flows. The confocal micro-PIV system is applied to the internal flow measurement of a droplet. We have measured three-dimensional distributions of three-component velocities of a droplet traveling in a 100 mu m ( width) x 58 mu m ( depth) channel. A volumetric velocity distribution inside a droplet is obtained by the confocal micro-PIV and the three-dimensional flow structure inside the droplet is investigated. The measurement results suggest that a three-dimensional and complex circulating flow is formed inside the droplet.
引用
收藏
页码:338 / 346
页数:9
相关论文
共 22 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]  
*ANSI ASME PTC, 1985, 191 ANSI ASME PTC
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]   Ensemble correlation PIV applied to bubble plumes rising in a bubble column [J].
Delnoij, E ;
Westerweel, J ;
Deen, NG ;
Kuipers, JAM ;
van Swaaij, WPM .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) :5159-5171
[5]   Integrated nanoliter systems [J].
Hong, JW ;
Quake, SR .
NATURE BIOTECHNOLOGY, 2003, 21 (10) :1179-1183
[6]   Handling of picoliter liquid samples in a poly(dimethylsiloxane)-based microfluidic device [J].
Hosokawa, K ;
Fujii, T ;
Endo, I .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4781-4785
[7]   Dielectrophoretic liquid actuation and nanodroplet formation [J].
Jones, TB ;
Gunji, M ;
Washizu, M ;
Feldman, MJ .
JOURNAL OF APPLIED PHYSICS, 2001, 89 (02) :1441-1448
[8]  
KARNIADAKIS GE, 2001, MICRO FLOWS FUNDAMEN
[9]   Molecular structure and function of the slit diaphragm: expression of nephrin in proteinuric states and in developing glomeruli [J].
Kawachi, H ;
Koike, H ;
Shimizu, F .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 :20-22
[10]  
McDonald JC, 2000, ELECTROPHORESIS, V21, P27, DOI 10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO