Validity of point-mass model in off-resonance dynamic atomic force microscopy

被引:4
|
作者
Rajput, Shatruhan Singh [1 ]
Deopa, Surya Pratap S. [1 ]
Ajith, V. J. [1 ]
Kamerkar, Sukrut C. [2 ]
Patil, Shivprasad [1 ]
机构
[1] Indian Inst Sci Educ & Res Pune, Dept Phys, Dr Homi Bhabha Rd, Pune 411008, Maharashtra, India
[2] Indian Inst Sci Educ & Res Pune, Dept Biol, Dr Homi Bhabha Rd, Pune 411008, Maharashtra, India
关键词
viscoelasticity; single-molecule force spectroscopy; atomic force microscope (AFM); amplitude-modulation AFM; SINGLE-MOLECULE; VISCOELASTIC PROPERTIES; FREQUENCY-RESPONSE; SPECTROSCOPY; AFM; RESOLUTION; LIQUID; TIP;
D O I
10.1088/1361-6528/ac0cb1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The quantitative measurement of viscoelasticity of nano-scale entities is an important goal of nanotechnology research and there is considerable progress with advent of dynamic atomic force microscopy. The hydrodynamics of cantilever, the force sensor in AFM measurements, plays a pivotal role in quantitative estimates of nano-scale viscoelasticity. The point-mass (PM) model, wherein the AFM cantilever is approximated as a point-mass with mass-less spring is widely used in dynamic AFM analysis and its validity, particularly in liquid environments, is debated. It is suggested that the cantilever must be treated as a continuous rectangular beam to obtain accurate estimates of nano-scale viscoelasticity of materials it is probing. Here, we derived equations, which relate stiffness and damping coefficient of the material under investigation to measured parameters, by approximating cantilever as a point-mass and also considering the full geometric details. These equations are derived for both tip-excited as well as base-excited cantilevers. We have performed off-resonance dynamic atomic force spectroscopy on a single protein molecule to investigate the validity of widely used PM model. We performed measurements with AFMs equipped with different cantilever excitation methods as well as detection schemes to measure cantilever response. The data was analyzed using both, continuous beam model and the PM model. We found that both models yield same results when the experiments are performed in truly off-resonance regime with small amplitudes and the cantilever stiffness is much higher than the interaction stiffness. Our findings suggest that a simple PM approximation based model is adequate to describe the dynamics, provided care is taken while performing experiments so that the approximations used in these models are valid.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Utilizing Off-Resonance and Dual-Frequency Excitation to Distinguish Attractive and Repulsive Surface Forces in Atomic Force Microscopy
    Dick, Andrew J.
    Solares, Santiago D.
    JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2011, 6 (03):
  • [2] Renormalization, resonance bifurcation, and phase contrast in dynamic atomic force microscopy
    Cantrell, Sean A.
    Cantrell, John H.
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (09)
  • [3] Scanning speed phenomenon in contact-resonance atomic force microscopy
    Glover, Christopher C.
    Killgore, Jason P.
    Tung, Ryan C.
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2018, 9 : 945 - 952
  • [4] Tapping atomic force microscopy imaging at phase resonance
    Sun, Baishun
    Xie, Chenchen
    Qu, Kaige
    Cao, Liang
    Yan, Jin
    Wang, Ying
    Tian, Liguo
    Zhang, Wenxiao
    Wang, Zuobin
    2021 IEEE INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO), 2021, : 47 - 50
  • [5] Modeling and Measuring Viscoelasticity with Dynamic Atomic Force Microscopy
    Thoren, Per-Anders
    Borgani, Riccardo
    Forchheimer, Daniel
    Dobryden, Illia
    Claesson, Per M.
    Kassa, Hailu G.
    Leclere, Philippe
    Wang, Yifan
    Jaeger, Heinrich M. .
    Haviland, David B.
    PHYSICAL REVIEW APPLIED, 2018, 10 (02):
  • [6] Monitoring the degradation and the corrosion of naphthenic acids by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry and atomic force microscopy
    Dias, Heloisa P.
    Pereira, Thieres M. C.
    Vanini, Gabriela
    Dixini, Pedro V.
    Celante, Vinicius G.
    Castro, Eustquio V. R.
    Vaz, Boniek G.
    Fleming, Felipe P.
    Gomes, Alexandre O.
    Aquije, Gloria M. F. V.
    Romao, Wanderson
    FUEL, 2014, 126 : 85 - 95
  • [7] Dynamic nano-triboelectrification using torsional resonance mode atomic force microscopy
    Cai, Wei
    Yao, Nan
    SCIENTIFIC REPORTS, 2016, 6
  • [8] Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
    Cantrell, John H.
    Cantrell, Sean A.
    JOURNAL OF APPLIED PHYSICS, 2016, 119 (12)
  • [9] Shortcomings of the Derjaguin-Muller-Toporov model in dynamic atomic force microscopy
    Theiler, Pius M.
    Ritz, Christian
    Stemmer, Andreas
    JOURNAL OF APPLIED PHYSICS, 2021, 130 (24)
  • [10] Enhancement of contact resonance atomic force microscopy subsurface imaging by mass-attached cantilevers
    Wang, Wenting
    Zhang, Wenhao
    Chen, Yuhang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (21)