Magnetization Transfer from Inhomogeneously Broadened Lines: A Potential Marker for Myelin

被引:105
作者
Varma, Gopal [1 ]
Duhamel, Guillaume [2 ]
de Bazelaire, Cedric [3 ]
Alsop, David C. [1 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02115 USA
[2] Aix Marseille Univ, CNRS, Ctr Resonance Magnet Biol & Med, Marseille, France
[3] Univ Paris Diderot, Hop St Louis, Serv Radiol, Paris, France
基金
美国国家卫生研究院;
关键词
brain; inhomogeneous broadening; MT; magnetization transfer; myelin; STATE NMR-SPECTROSCOPY; IN-VIVO; MULTIPLE-SCLEROSIS; WHITE-MATTER; HUMAN BRAIN; TRANSFER RATIO; RESONANCE; RELAXATION; MODEL; WATER;
D O I
10.1002/mrm.25174
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo characterize a new approach to magnetization transfer (MT) imaging with improved specificity for myelinated tissues relative to conventional MT. MethodsMagnetization transfer preparation sequences were implemented with all radiofrequency power centered on a single frequency and also with power evenly divided between positive and negative frequencies. Dual frequency saturation was achieved both with short, alternating frequency pulses and with sinusoidal modulation of continuous irradiation. Images following preparation were acquired with a single shot fast spin echo sequence. Single and dual frequency preparation should achieve similar saturation of molecules except for those with inhomogenously broadened lines. Inhomogenous MT (IHMT) images were generated by subtraction of dual from single frequency prepared images. IHMT imaging was performed with different power and frequency in the brains of normal volunteers. ResultsThe IHMT method demonstrated a greater white/gray matter ratio than conventional MT and virtual elimination of signal in scalp and other unmyelinated tissues. IHMT exceeded 5% of the fully relaxed magnetization in white matter. A broad frequency spectrum and signs of axonal angular dependence at high frequency were observed that are consistent with dipolar broadening. ConclusionIHMT shows promise for myelin-specific imaging. Further study of physical mechanisms and diagnostic sensitivity are merited. Magn Reson Med 73:614-622, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:614 / 622
页数:9
相关论文
共 41 条
  • [1] The sensitivity of low flip angle RARE imaging
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 176 - 184
  • [2] Bagley LJ, 2000, J MAGN RESON IMAGING, V11, P1, DOI 10.1002/(SICI)1522-2586(200001)11:1<1::AID-JMRI1>3.0.CO
  • [3] 2-H
  • [4] Berry I, 1999, J MAGN RESON IMAGING, V9, P441, DOI 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO
  • [5] 2-R
  • [6] RELAXATION EFFECTS IN NUCLEAR MAGNETIC RESONANCE ABSORPTION
    BLOEMBERGEN, N
    PURCELL, EM
    POUND, RV
    [J]. PHYSICAL REVIEW, 1948, 73 (07): : 679 - 712
  • [7] NUCLEAR MAGNETIC-RESONANCE LINE-SHAPES IN LYOTROPIC LIQUID-CRYSTALS AND RELATED SYSTEMS
    BLOOM, M
    BURNELL, EE
    ROEDER, SBW
    VALIC, MI
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1977, 66 (07) : 3012 - 3020
  • [8] NUCLEAR MAGNETIC-RESONANCE STUDIES OF STRUCTURE OF MODEL MEMBRANE SYSTEMS - EFFECT OF SURFACE CURVATURE
    CHAN, SI
    SHEETZ, MP
    SEITER, CHA
    FEIGENSON, GW
    HSU, M
    LAU, A
    YAU, A
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1973, 222 (DEC31) : 499 - 522
  • [9] NUCLEAR RELAXATION STUDIES OF LECITHIN BILAYERS
    CHAN, SI
    FEIGENSON, GW
    SEITER, CHA
    [J]. NATURE, 1971, 231 (5298) : 110 - +
  • [10] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659