Automatic detection and quantification of ground-glass opacities on high-resolution CT using multiple neural networks: Comparison with a density mask

被引:68
作者
Kauczor, HU
Heitmann, K
Heussel, CP
Marwede, D
Uthmann, T
Thelen, M
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Inst Comp Sci, D-55128 Mainz, Germany
[3] Univ Klinikum Lubeck, Inst Radiol, D-23538 Lubeck, Germany
关键词
D O I
10.2214/ajr.175.5.1751329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, We compared multiple neural networks with a density mask for the automatic detection and quantification of ground-glass opacities on high-resolution CT under clinical conditions. SUBJECTS AND METHODS. Eighty-four patients (54 men and 30 women; age range, 18-82 years; mean age, 49 years) with a total of 99 consecutive high-resolution CT scans were enrolled in the study. The neural network was designed to detect ground-glass opacities with high sensitivity and to omit air-tissue interfaces to increase specificity. The results of the neural network were compared with those of a density mask (thresholds, -750/-300 H), with a radiologist serving as the gold standard. RESULTS. The neural network classified 6% of the total lung area as ground-glass opacities. The density mask failed to detect 1.3%, and this percentage represented the increase in sensitivity that was achieved by the neural network. The density mask identified another 17.3% of the total lung area to be ground-glass opacities that were not detected by the neural network. This area represented the increase in specificity achieved by the neural network. Related to the extent of the ground-glass opacities as classified by the radiologist. the neural network (density mask) reached a sensitivity of 99% (89%), specificity of 83% (55%). positive predictive value of 78% (18%), negative predictive value of 99% (98%), and accuracy of 89% (58%). CONCLUSION. Automatic segmentation and quantification of ground-glass opacities on high-resolution CT by a neural network are sufficiently accurate to be implemented for the preinterpretation of images in a clinical environment; it is superior to a double-threshold density mask.
引用
收藏
页码:1329 / 1334
页数:6
相关论文
共 23 条
[1]   Effect of an artificial neural network on radiologists' performance in the differential diagnosis of interstitial lung disease using chest radiographs [J].
Ashizawa, K ;
MacMahon, H ;
Ishida, T ;
Nakamura, K ;
Vyborny, CJ ;
Katsuragawa, S ;
Doi, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1311-1315
[2]   NEURAL NETWORKS IN RADIOLOGIC-DIAGNOSIS .1. INTRODUCTION AND ILLUSTRATION [J].
BOONE, JM ;
GROSS, GW ;
GRECOHUNT, V .
INVESTIGATIVE RADIOLOGY, 1990, 25 (09) :1012-1016
[3]   NEURAL NETWORKS AT THE CROSSROADS [J].
BOONE, JM .
RADIOLOGY, 1993, 189 (02) :357-359
[4]   Method for segmenting chest CT image data using an anatomical model: Preliminary results [J].
Brown, MS ;
McNitt-Gray, MF ;
Mankovich, NJ ;
Goldin, JG ;
Hiller, J ;
Wilson, LS ;
Aberle, DR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :828-839
[5]   Usual interstitial pneumonia - Quantitative assessment of high-resolution computed tomography findings by computer-assisted texture-based image analysis [J].
Delorme, S ;
KellerReichenbecher, MA ;
Zuna, I ;
Schlegel, W ;
vanKaick, G .
INVESTIGATIVE RADIOLOGY, 1997, 32 (09) :566-574
[6]  
Dohring W, 1986, Rofo, V144, P135, DOI 10.1055/s-2008-1048761
[7]   COMPUTERIZED DETECTION OF PULMONARY NODULES IN COMPUTED-TOMOGRAPHY IMAGES [J].
GIGER, ML ;
BAE, KT ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1994, 29 (04) :459-465
[8]   DETERMINING THE LIKELIHOOD OF MALIGNANCY IN SOLITARY PULMONARY NODULES WITH BAYESIAN-ANALYSIS .2. APPLICATION [J].
GURNEY, JW ;
LYDDON, DM ;
MCKAY, JA .
RADIOLOGY, 1993, 186 (02) :415-422
[9]   SOLITARY PULMONARY NODULES - DETERMINING THE LIKELIHOOD OF MALIGNANCY WITH NEURAL-NETWORK ANALYSIS [J].
GURNEY, JW ;
SWENSEN, SJ .
RADIOLOGY, 1995, 196 (03) :823-829
[10]   Automatic detection of ground glass opacities on lung HRCT using multiple neural networks [J].
Heitmann, KR ;
Kauczor, HU ;
Mildenberger, P ;
Uthmann, T ;
Perl, J ;
Thelen, M .
EUROPEAN RADIOLOGY, 1997, 7 (09) :1463-1472