In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry

被引:197
作者
Georgakopoulos, D
Mitzner, WA
Chen, CH
Byrne, BJ
Millar, HD
Hare, JM
Kass, DA
机构
[1] Johns Hopkins Med Inst, Sch Med, Dept Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Med Inst, Sch Med, Div Physiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Med Inst, Sch Publ Hlth, Div Physiol, Baltimore, MD 21287 USA
[4] Johns Hopkins Med Inst, Sch Publ Hlth, Dept Med, Baltimore, MD 21287 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 04期
关键词
mouse; ventricular function; hemodynamics; conductance volumetry;
D O I
10.1152/ajpheart.1998.274.4.H1416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mouse is the species of choice for creating genetically engineered models of human disease. To study detailed systolic and diastolic left ventricular (LV) chamber mechanics in mice in vivo, we developed a miniaturized conductance-manometer system. alpha-Chloralose-urethananesthetized animals were instrumented with a two-electrode pressure-volume catheter advanced via the LV apex to the aortic root. Custom electronics provided time-varying conductances related to cavity volume. Baseline hemodynamics were similar to values in conscious animals: 634 +/- 14 beats/min, 112 +/- 4 mmHg, 5.3 +/- 0.8 mmHg, and 11,777 +/- 732 mmHg/s for heart rate, end-systolic and end-diastolic pressures, and maximum first derivative of ventricular pressure with respect to time (dP/dt(max)), respectively. Catheter stroke volume during preload reduction by inferior vena caval occlusion correlated with that by ultrasound aortic flow probe (r(2) = 0.98). This maneuver yielded end-systolic elastances of 79 +/- 21 mmHg/mu l, preload-recruitable stroke work of 82 +/- 5.6 mmHg, and slope of dP/dt(max)-end-diastolic volume relation of 699 +/- 100 mmHg.s(-1).mu l(-1), and these relations varied predictably with acute inotropic interventions. The control normalized time-varying elastance curve was similar to human data, further supporting comparable chamber mechanics between species. This novel approach should greatly help assess cardiovascular function in the blood-perfused murine heart.
引用
收藏
页码:H1416 / H1422
页数:7
相关论文
共 50 条
[41]   Pressure-Volume Analysis Illustrating the Mechanisms of Short-Term Hemodynamic Effects Produced by Premature Ventricular Contractions [J].
Brener, Michael, I ;
Burkhoff, Daniel ;
Basir, Mir Babar ;
Alqarqaz, Mohammad .
CIRCULATION-HEART FAILURE, 2021, 14 (03) :419-420
[42]   Clinical Assessment of Elastic Restoring Forces of The Left Ventricle by Multivariate Multiparametric Fitting of Conventional Pressure-Volume Curves [J].
Perez del Villar, Candelas ;
Bermejo, Javier ;
Yotti, Raquel ;
del Alamo, Juan Carlos ;
Barrio, Alicia ;
Benito, Yolanda ;
Gonzalez-Mansilla, Ana ;
Sanz, Ricardo ;
Elizaga, Jaime ;
Fernandez-Aviles, Francisco .
CIRCULATION, 2012, 126 (21)
[43]   Left ventricular pressure-volume relationships during normal growth and development in the adult rat - studies in 8-and 50-week-old male Wistar rats [J].
Bal, MP ;
Vries, WB ;
Leij, FR ;
Oosterhout, MFM ;
Baan, J ;
Wall, EE ;
Bel, F ;
Steendijk, P .
ACTA PHYSIOLOGICA SCANDINAVICA, 2005, 185 (03) :181-191
[44]   Ethnic differences in left ventricular structure: Relations to hemodynamics and diurnal blood pressure variation [J].
Hinderliter, AL ;
Blumenthal, JA ;
Waugh, R ;
Chilukuri, M ;
Sherwood, A .
AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (01) :43-49
[45]   Right ventricular support for off-pump coronary artery bypass grafting studied with bi-ventricular pressure-volume loops in sheep [J].
Dekker, AL ;
Geskes, GG ;
Cramers, AA ;
Dassen, WR ;
Maessen, JG ;
Prenger, KB ;
van der Veen, FH .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (02) :179-184
[46]   New Insights Into Right Ventricular Performance During Exercise Using High-Fidelity Conductance Catheters to Generate Pressure Volume Loops [J].
Cornwell, William K., III ;
Coe, Greg ;
Ambardekar, Amrut ;
Pal, Jay ;
Tompkins, Christine ;
Zipse, Matthew ;
Wolfel, Gene ;
Brieke, Andreas ;
Levine, Benjamin ;
Kohrt, Wendy .
CIRCULATION, 2018, 138
[47]   Noninvasive Left Ventricle Pressure-Volume Loop Determination Method With Cardiac Magnetic Resonance Imaging and Carotid Tonometry Using a Physics-Informed Approach [J].
Liu, Jing ;
Bregasi, Alda ;
Mitchell, Gary F. ;
Pahlevan, Niema M. .
CIRCULATION, 2023, 148
[48]   Assessment of PEEP-Ventilation and the Time Point of Parallel-Conductance Determination for Pressure-Volume Analysis Under β-Adrenergic Stimulation in Mice [J].
Bacmeister, Lucas ;
Segin, Sebastian ;
Medert, Rebekka ;
Lindner, Diana ;
Freichel, Marc ;
Londono, Juan E. Camacho .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2019, 6
[49]   Quantitative Assessment of Cardiac Output and Left Ventricular Function by Noninvasive Phase-Contrast and Cine MRI: Validation Study With Invasive Pressure-Volume Loop Analysis in a Swine Model [J].
Lin, Hung-Yu ;
Freed, Darren ;
Lee, Trevor W. R. ;
Arora, Rakesh C. ;
Ali, Ayyaz ;
Almoustadi, Waiel ;
Xiang, Bo ;
Wang, Fei ;
Large, Stephen ;
King, Scott B. ;
Tomanek, Boguslaw ;
Tian, Ganghong .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) :203-210
[50]   Physical determinants of left ventricular isovolumic pressure decline: model prediction with in vivo validation [J].
Chung, Charles S. ;
Kovacs, Sandor J. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2008, 294 (04) :H1589-H1596