Extending the depth of focus of fiber-optic optical coherence tomography using a chromatic dual-focus design

被引:9
作者
Li, Jinhan [1 ]
Luo, Yuemei [1 ]
Wang, Xianghong [1 ]
Wang, Nanshuo [1 ]
Bo, En [1 ]
Chen, Si [1 ]
Chen, Shufen [1 ]
Chen, Shi [1 ]
Tsai, Meng-Tsan [3 ,4 ]
Liu, Linbo [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 637459, Singapore
[3] Chang Gung Univ, Dept Elect Engn, Taoyuan 33302, Taiwan
[4] Chang Gung Mem Hosp, Dept Dermatol, Linkou 33305, Taiwan
基金
中国国家自然科学基金; 新加坡国家研究基金会; 英国医学研究理事会;
关键词
IN-VIVO; SYNTHETIC-APERTURE; EXTENSION; MICROSCOPY; FILTERS; PROBE; BEAM;
D O I
10.1364/AO.57.006040
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a dual-focus fiber-optic probe designed to extend depth of focus (DOF) in high-resolution endoscopic optical coherence tomography. We exploited the broad spectral bandwidth of a supercontinuum source and, in the fiber probe, the foci of the 750-1000 nm and 1100-1450 nm inputs were axially chromatically shifted. The interference signals from the two spectral bands were measured with a Si camera-based spectrometer and an InGaAs camera-based spectrometer, respectively. We verified the feasibility of the design using a phantom composed of microparticles and swine small intestine tissue ex vivo. The results showed that a transverse resolution below 5 mu m over 300 mu m could be maintained, and that the extended DOF was 2 times larger than that of the single focus probe via the use of dual spectral band inputs and a chromatic focal shift. (C) 2018 Optical Society of America
引用
收藏
页码:6040 / 6046
页数:7
相关论文
共 26 条
  • [11] Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography
    Liu, Linbo
    Gardecki, Joseph A.
    Nadkarni, Seemantini K.
    Toussaint, Jimmy D.
    Yagi, Yukako
    Bouma, Brett E.
    Tearney, Guillermo J.
    [J]. NATURE MEDICINE, 2011, 17 (08) : 1010 - U132
  • [12] Ultrathin fiber probes with extended depth of focus for optical coherence tomography
    Lorenser, Dirk
    Yang, Xiaojie
    Sampson, David D.
    [J]. OPTICS LETTERS, 2012, 37 (10) : 1616 - 1618
  • [13] Endomicroscopic optical coherence tomography for cellular resolution imaging of gastrointestinal tracts
    Luo, Yuemei
    Cui, Dongyao
    Yu, Xiaojun
    Bo, En
    Wang, Xianghong
    Wang, Nanshuo
    Braganza, Cilwyn S.
    Chen, Shufen
    Liu, Xinyu
    Xiong, Qiaozhou
    Chen, Si
    Chen, Shi
    Liu, Linbo
    [J]. JOURNAL OF BIOPHOTONICS, 2018, 11 (04)
  • [14] Focus-extension by depth-encoded synthetic aperture in Optical Coherence Tomography
    Mo, Jianhua
    de Groot, Mattijs
    de Boer, Johannes F.
    [J]. OPTICS EXPRESS, 2013, 21 (08): : 10048 - 10061
  • [15] Video-rate confocal scanning laser microscope for imaging human tissues in vivo
    Rajadhyaksha, M
    Anderson, RR
    Webb, RH
    [J]. APPLIED OPTICS, 1999, 38 (10) : 2105 - 2115
  • [16] Interferometric synthetic aperture microscopy
    Ralston, Tyler S.
    Marks, Daniel L.
    Carney, P. Scott
    Boppart, Stephen A.
    [J]. NATURE PHYSICS, 2007, 3 (02) : 129 - 134
  • [17] Novel endoscope with increased depth of field for imaging human nasal tissue by microscopic optical coherence tomography
    Schulz-Hildebrandt, Hinnerk
    Pieper, Mario
    Stehmar, Charlotte
    Ahrens, Martin
    Idel, Christian
    Wollenberg, Barbara
    Koenig, Peter
    Huettmann, Gereon
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (02): : 636 - 647
  • [18] In vivo endoscopic optical biopsy with optical coherence tomography
    Tearney, GJ
    Brezinski, ME
    Bouma, BE
    Boppart, SA
    Pitris, C
    Southern, JF
    Fujimoto, JG
    [J]. SCIENCE, 1997, 276 (5321) : 2037 - 2039
  • [19] Ultra long high resolution beam by multi-zone rotationally symmetrical complex pupil filter
    Xu, Yingshun
    Singh, Janak
    Sheppard, Colin J. R.
    Chen, Nanguang
    [J]. OPTICS EXPRESS, 2007, 15 (10) : 6409 - 6413
  • [20] Micromachined array tip for multifocus fiber-based optical coherence tomography
    Yang, VXD
    Munce, N
    Pekar, J
    Gordon, ML
    Lo, S
    Marcon, NE
    Wilson, BC
    Vitkin, IA