In situ high-precision Ni isotope analysis of metals by femtosecond-LA-MC-ICP-MS

被引:14
作者
Weyrauch, Mona [1 ]
Oeser, Martin [1 ]
Brueske, Annika [1 ]
Weyer, Stefan [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Callinstr 3, D-30167 Hannover, Germany
关键词
LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; NICKEL ISOTOPES; FRACTIONATION; FE; DIFFUSION; RATIOS; CU;
D O I
10.1039/c7ja00147a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, an in situ technique for high-precision determination of Ni stable isotope ratios by femtosecondlaser ablation-multicollector-ICP-MS (fs-LA-MC-ICP-MS) was developed. With this technique, the Ni isotope compositions of Ni-bearing steels (NIST RM-1226 and BAM D 184-1) and a Ni-rod (standard 10209 from MAC) were determined, both by fs-LA-MC-ICP-MS analyses and by solution MC- ICP-MS, the latter in order to verify the results of the in situ analyses. The LA-MC-ICP-MS analyses revealed that all analyzed standard materials were homogeneous within analytical uncertainties and may thus be suitable as external standards for Ni isotope determination by in situ analysis of metal phases and sulfides. Bulk solution MC-ICP-MS and LAMC-ICP-MS analyses of these metals agreed within their analytical uncertainties of 0.03% for the solution analyses and <0.1 parts per thousand (2SD, over 12 months) for the LA-MC-ICP-MS analyses. These results imply that the accuracy of the in situ analyses of metals is better than 0.1%. The average of four solution nebulization analyses of the Ni-rod and D 184-1, and of 16 analyses of the NIST RM-1226 material, revealed delta Ni-62 values of-0.26 parts per thousand, 0.12 parts per thousand, and-0.28 parts per thousand relative to NIST SRM-986, respectively. In order to show the applicability and potential of the presented method, the Ni and Fe isotope compositions of a kamacite-taenite interface in IAB iron meteorite Canyon Diablo were determined by fs-LA-MC-ICP-MS analyses. The isotope profile reveals lighter Fe isotopes in kamacite than in taenite, while the Ni isotope composition is vice versa. Evolution of the isotope signals along the interface of these metal phases strongly points to diffusion driven fractionation of Fe and Ni isotopes during the formation of kamacite by the replacement of taenite. Due to Fe-Ni exchange diffusion between taenite and kamacite and the generally faster diffusion of light isotopes compared to heavy isotopes, the remaining taenite is left with heavier Fe and lighter Ni isotope compositions than the newly formed kamacite. Demonstration of such detailed information about the diffusion processes in the kamacite-taenite system was not possible before, due to the lack of an appropriate high-precision and high spatial resolution technique for in situ Ni isotope analyses.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 50 条
  • [41] High-Precision Mass-Dependent Molybdenum Isotope Variations in Magmatic Rocks Determined by Double-Spike MC-ICP-MS
    Willbold, Matthias
    Hibbert, Kate
    Lai, Yi-Jen
    Freymuth, Heye
    Hin, Remco C.
    Coath, Christopher
    Vils, Flurin
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2016, 40 (03) : 389 - 403
  • [42] High-precision zinc isotopic characterization of twenty soil reference materials from China determined by MC-ICP-MS
    Zhai, Hua-Ye
    Wang, Xuan-Ce
    Li, Chao-Feng
    Wilde, Simon A.
    Li, Xiang-Zhong
    Xu, Bei
    Zhang, Xian-Liang
    Zhang, Ping
    RSC ADVANCES, 2023, 13 (28) : 19030 - 19038
  • [43] In situ Sn isotope analysis of cassiterite (SnO2) by nanosecond laser ablation MC-ICP-MS
    She, Jia-Xin
    Li, Weiqiang
    An, Shichao
    Yang, Tao
    Zhang, Rongqing
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (05) : 1043 - 1056
  • [44] Evaluation of UV-fs-LA-MC-ICP-MS for Precise in situ Copper Isotopic Microanalysis of Cubanite
    Ikehata, Kei
    Hirata, Takafumi
    ANALYTICAL SCIENCES, 2013, 29 (12) : 1213 - 1217
  • [45] Accurate and High-Precision Determination of Boron Isotopic Ratios at Low Concentration by MC-ICP-MS (Neptune)
    Guerrot, Catherine
    Millot, Romain
    Robert, Michele
    Negrel, Philippe
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2011, 35 (02) : 275 - 284
  • [46] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [47] An efficient Li dual-column system and high-precision Li isotope measurement of high matrix and low-Li samples by MC-ICP-MS
    Cao, Cheng
    Li, Tao
    Chen, Tianyu
    Li, Gaojun
    Li, Wei
    Chen, Jun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (08) : 1602 - 1610
  • [48] Sr-isotope analysis of speleothems by LA-MC-ICP-MS: High temporal resolution and fast data acquisition
    Weber, Michael
    Wassenburg, Jasper A.
    Jochum, Klaus Peter
    Breitenbach, Sebastian F. M.
    Oster, Jessica
    Scholz, Denis
    CHEMICAL GEOLOGY, 2017, 468 : 63 - 74
  • [49] High-precision Copper and Zinc Isotopic Measurements in Igneous Rock Standards Using Large-geometry MC-ICP-MS
    Zhu, Yangtao
    Li, Ming
    Wang, Zaicong
    Zou, Zongqi
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chai, Xinna
    ATOMIC SPECTROSCOPY, 2019, 40 (06) : 206 - 214
  • [50] High-precision potassium isotopic analysis by MC-ICP-MS: an inter-laboratory comparison and refined K atomic weight
    Chen, Heng
    Tian, Zhen
    Tuller-Ross, Brenna
    Korotev, Randy L.
    Wang, Kun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (01) : 160 - 171