In situ high-precision Ni isotope analysis of metals by femtosecond-LA-MC-ICP-MS

被引:14
作者
Weyrauch, Mona [1 ]
Oeser, Martin [1 ]
Brueske, Annika [1 ]
Weyer, Stefan [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Callinstr 3, D-30167 Hannover, Germany
关键词
LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; NICKEL ISOTOPES; FRACTIONATION; FE; DIFFUSION; RATIOS; CU;
D O I
10.1039/c7ja00147a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, an in situ technique for high-precision determination of Ni stable isotope ratios by femtosecondlaser ablation-multicollector-ICP-MS (fs-LA-MC-ICP-MS) was developed. With this technique, the Ni isotope compositions of Ni-bearing steels (NIST RM-1226 and BAM D 184-1) and a Ni-rod (standard 10209 from MAC) were determined, both by fs-LA-MC-ICP-MS analyses and by solution MC- ICP-MS, the latter in order to verify the results of the in situ analyses. The LA-MC-ICP-MS analyses revealed that all analyzed standard materials were homogeneous within analytical uncertainties and may thus be suitable as external standards for Ni isotope determination by in situ analysis of metal phases and sulfides. Bulk solution MC-ICP-MS and LAMC-ICP-MS analyses of these metals agreed within their analytical uncertainties of 0.03% for the solution analyses and <0.1 parts per thousand (2SD, over 12 months) for the LA-MC-ICP-MS analyses. These results imply that the accuracy of the in situ analyses of metals is better than 0.1%. The average of four solution nebulization analyses of the Ni-rod and D 184-1, and of 16 analyses of the NIST RM-1226 material, revealed delta Ni-62 values of-0.26 parts per thousand, 0.12 parts per thousand, and-0.28 parts per thousand relative to NIST SRM-986, respectively. In order to show the applicability and potential of the presented method, the Ni and Fe isotope compositions of a kamacite-taenite interface in IAB iron meteorite Canyon Diablo were determined by fs-LA-MC-ICP-MS analyses. The isotope profile reveals lighter Fe isotopes in kamacite than in taenite, while the Ni isotope composition is vice versa. Evolution of the isotope signals along the interface of these metal phases strongly points to diffusion driven fractionation of Fe and Ni isotopes during the formation of kamacite by the replacement of taenite. Due to Fe-Ni exchange diffusion between taenite and kamacite and the generally faster diffusion of light isotopes compared to heavy isotopes, the remaining taenite is left with heavier Fe and lighter Ni isotope compositions than the newly formed kamacite. Demonstration of such detailed information about the diffusion processes in the kamacite-taenite system was not possible before, due to the lack of an appropriate high-precision and high spatial resolution technique for in situ Ni isotope analyses.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 50 条
  • [31] In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS
    Huang, Chao
    Wang, Hao
    Xie, Liewen
    Nie, Nicole X.
    Yang, Yueheng
    Zhao, Xinmiao
    Li, Jin
    Tian, Heng-Ci
    Wu, Shitou
    Xu, Lei
    Yang, Jinhui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2165 - 2175
  • [32] Extraction of Pb and Zn from crude oil for high-precision isotopic analysis by MC-ICP-MS
    Fetter, Nadege
    Blichert-Toft, Janne
    Telouk, Philippe
    Albarede, Francis
    CHEMICAL GEOLOGY, 2019, 511 : 112 - 122
  • [33] Application of three data evaluation methods for in situ iron isotope analysis using the ns-LA-MC-ICP-MS technique
    Yang, Qichao
    Gong, Hongmei
    Wang, Xiaohong
    Duan, Meng
    Xiao, Yuanyuan
    Sun, Weidong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1000 - 1009
  • [34] High -precision molybdenum isotope analysis of low-Mo igneous rock samples by MC?ICP?MS
    Fan, Jing-Jing
    Li, Jie
    Wang, Qiang
    Zhang, Le
    Zhang, Jing
    Zeng, Xiang-Lan
    Ma, Lin
    Wang, Zi-Long
    CHEMICAL GEOLOGY, 2020, 545 (545)
  • [35] Matrix independent and interference free in situ boron isotope analysis by laser ablation MC-ICP-MS/MS
    Standish, Christopher D.
    Milton, J. Andy
    Brown, Rachel M.
    Foster, Gavin L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (05) : 1309 - 1322
  • [36] High precision determination of silver isotope ratios in commercial products by MC-ICP-MS
    Yang, Lu
    Dabek-Zlotorzynska, Ewa
    Celo, Valbona
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1564 - 1569
  • [37] High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS
    Bai, Jiang-Hao
    Lin, Mang
    Zhong, Song-Xiong
    Deng, Yi-Nan
    Zhang, Le
    Luo, Kai
    Wu, Hao
    Ma, Jin-Long
    Wei, Gang-Jian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 629 - 637
  • [38] Efficient Cd separation protocols for high-precision cadmium isotope analyses of diverse samples by double spike MC-ICP-MS
    Huang, Yihang
    Jia, Zijian
    Xu, Hui
    Kreissig, Katharina
    Coles, Barry J.
    Rehkamper, Mark
    Moore, Rebekah E. T.
    TALANTA, 2025, 285
  • [39] High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
    Gao, Bing-Yu
    Su, Ben-Xun
    Li, Wen-Jun
    Yuan, Meng
    Sun, Jian
    Zhao, Ye
    Liu, Xia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2111 - 2121
  • [40] Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS
    Scott, Sean R.
    Turner, Gabrielle L.
    Gartman, Brandy N.
    Anguiano, Sonia Alcantar
    Melby, Kali M.
    Allen, Barbara E.
    Minton, Travis D.
    Risenhuber, Matthew A.
    Hobbs, Kirby P.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 1098 - 1105