In this study, an in situ technique for high-precision determination of Ni stable isotope ratios by femtosecondlaser ablation-multicollector-ICP-MS (fs-LA-MC-ICP-MS) was developed. With this technique, the Ni isotope compositions of Ni-bearing steels (NIST RM-1226 and BAM D 184-1) and a Ni-rod (standard 10209 from MAC) were determined, both by fs-LA-MC-ICP-MS analyses and by solution MC- ICP-MS, the latter in order to verify the results of the in situ analyses. The LA-MC-ICP-MS analyses revealed that all analyzed standard materials were homogeneous within analytical uncertainties and may thus be suitable as external standards for Ni isotope determination by in situ analysis of metal phases and sulfides. Bulk solution MC-ICP-MS and LAMC-ICP-MS analyses of these metals agreed within their analytical uncertainties of 0.03% for the solution analyses and <0.1 parts per thousand (2SD, over 12 months) for the LA-MC-ICP-MS analyses. These results imply that the accuracy of the in situ analyses of metals is better than 0.1%. The average of four solution nebulization analyses of the Ni-rod and D 184-1, and of 16 analyses of the NIST RM-1226 material, revealed delta Ni-62 values of-0.26 parts per thousand, 0.12 parts per thousand, and-0.28 parts per thousand relative to NIST SRM-986, respectively. In order to show the applicability and potential of the presented method, the Ni and Fe isotope compositions of a kamacite-taenite interface in IAB iron meteorite Canyon Diablo were determined by fs-LA-MC-ICP-MS analyses. The isotope profile reveals lighter Fe isotopes in kamacite than in taenite, while the Ni isotope composition is vice versa. Evolution of the isotope signals along the interface of these metal phases strongly points to diffusion driven fractionation of Fe and Ni isotopes during the formation of kamacite by the replacement of taenite. Due to Fe-Ni exchange diffusion between taenite and kamacite and the generally faster diffusion of light isotopes compared to heavy isotopes, the remaining taenite is left with heavier Fe and lighter Ni isotope compositions than the newly formed kamacite. Demonstration of such detailed information about the diffusion processes in the kamacite-taenite system was not possible before, due to the lack of an appropriate high-precision and high spatial resolution technique for in situ Ni isotope analyses.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 50 条
  • [1] In situ high-precision lithium isotope analyses at low concentration levels with femtosecond-LA-MC-ICP-MS
    Steinmann, Lena K.
    Oeser, Martin
    Horn, Ingo
    Seitz, Hans-Michael
    Weyer, Stefan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1447 - 1458
  • [2] High-Precision Fe and Mg Isotope Ratios of Silicate Reference Glasses Determined In Situ by Femtosecond LA-MC-ICP-MS and by Solution Nebulisation MC-ICP-MS
    Oeser, Martin
    Weyer, Stefan
    Horn, Ingo
    Schuth, Stephan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 311 - 328
  • [3] High-precision copper and iron isotope analysis of igneous rock standards by MC-ICP-MS
    Liu, Sheng-Ao
    Li, Dandan
    Li, Shuguang
    Teng, Fang-Zhen
    Ke, Shan
    He, Yongsheng
    Lu, Yinghuai
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (01) : 122 - 133
  • [4] In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS
    Kaufmann, A. B.
    Lazarov, M.
    Kiefer, S.
    Majzlan, J.
    Weyer, S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (07) : 1554 - 1567
  • [5] High-precision barium isotope measurements by MC-ICP-MS
    Nan, Xiaoyun
    Wu, Fei
    Zhang, Zhaofeng
    Hou, Zhenhui
    Huang, Fang
    Yu, Huimin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (11) : 2307 - 2315
  • [6] High-Precision Iron Isotope Analysis of Geological Reference Materials by High-Resolution MC-ICP-MS
    He, Yongsheng
    Ke, Shan
    Teng, Fang-Zhen
    Wang, Tiantian
    Wu, Hongjie
    Lu, Yinhuai
    Li, Shuguang
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2015, 39 (03) : 341 - 356
  • [7] High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
    Wang, Jing
    Su, Ben-Xun
    Tang, Dong-Mei
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2589 - 2598
  • [8] High-precision potassium isotope analysis using the Nu Sapphire collision cell (CC)-MC-ICP-MS
    Li, Wenjun
    Cui, Mengmeng
    Pan, Qiqi
    Wang, Jing
    Gao, Bingyu
    Liu, Shanke
    Yuan, Meng
    Su, Benxun
    Zhao, Ye
    Teng, Fang-Zhen
    Han, Guilin
    SCIENCE CHINA-EARTH SCIENCES, 2022, 65 (08) : 1510 - 1521
  • [9] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (08) : 2021 - 2029
  • [10] An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Miao, Zhuang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1330 - 1339