摘要
COWDEN syndrome is a rare autosomal dominant disorder caused by mutation in the phosphatase and tensin homolog gene.(1) It is characterized by multiple mucocutaneous hamartomas, malignancies of breast, thyroid, and genitourinary system, and a variety of intracranial abnormalities including meningiomas and vascular malformations.(2,3) Difficulties in airway management can be encountered in these patients because of the presence of papillomatous lesions on the mucosa of pharyngeal wall, lingual tonsils, and epiglottis.(4,5) In fact, critical airway obstruction and bleeding during induction of anesthesia requiring emergent tracheostomy has been described in association with Cowden syndrome.(5) We describe a case of successful airway management with combined use of a Glidescope (R) videolaryngoscope (Verathon Medical, Bothell, WA) and a fiberoptic bronchoscope in a patient with Cowden syndrome with papillomatous lesions of the airway.
引用
收藏
页码:253 / 255
页数:3
相关论文
共 19 条
[1]   Complications associated with the use of the GlideScope® videolaryngoscope [J].
Cooper, Richard M. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (01) :54-57
[2]   COWDENS DISEASE - A RARE BUT IMPORTANT MANIFESTATION OF ORAL PAPILLOMATOSIS [J].
DEVLIN, MF ;
BARRIE, R ;
WARDBOOTH, RP .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1992, 30 (05) :335-336
[3]   The GlideScope® video laryngoscope [J].
Doyle, DJ .
ANAESTHESIA, 2005, 60 (04) :414-415
[4]  
Greer JR, 2001, ANESTHESIOLOGY, V94, P729
[5]   Penetrating injury of the soft palate during GlideScope® intubation [J].
Hsu, Wei-Ti ;
Hsu, Shu-Chia ;
Lee, Yung-Lung ;
Huang, Jinn-Sheng ;
Chen, Chao-Liang .
ANESTHESIA AND ANALGESIA, 2007, 104 (06) :1609-1610
[6]   Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation [J].
Johnson, DM ;
From, AM ;
Smith, RB ;
From, RP ;
Maktabi, MA .
ANESTHESIOLOGY, 2005, 102 (05) :910-914
[7]   FIBEROPTIC INTUBATION - INFLUENCE OF TRACHEAL TUBE TIP DESIGN [J].
JONES, HE ;
PEARCE, AC ;
MOORE, P .
ANAESTHESIA, 1993, 48 (08) :672-674
[8]   The Parker Flex-Tip tube versus a standard tube for fiberoptic orotracheal intubation - A randomized double-blind study [J].
Kristensen, MS .
ANESTHESIOLOGY, 2003, 98 (02) :354-358
[9]   COWDENS DISEASE - A POSSIBLE NEW SYMPTOM COMPLEX WITH MULTIPLE SYSTEM INVOLVEMENT [J].
LLOYD, KM ;
DENNIS, M .
ANNALS OF INTERNAL MEDICINE, 1963, 58 (01) :136-+
[10]   A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation [J].
Lucas, DN ;
Yentis, SM .
ANAESTHESIA, 2000, 55 (04) :358-361