Characterization of a novel chelating resin of enhanced hydrophilicity and its analytical utility for preconcentration of trace metal ions

被引:43
作者
Islam, Aminul [1 ]
Laskar, Mohammad Asaduddin [1 ]
Ahmad, Akil [1 ]
机构
[1] Aligarh Muslim Univ, Dept Chem, Analyt Res Lab, Aligarh 202002, Uttar Pradesh, India
关键词
Chelating resin; p-Hydroxybenzoic acid; Sorption behavior; Trace metal ions; Solid phase extraction; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; AMBERLITE XAD-16; WATER SAMPLES; HEAVY-METALS; SEPARATION; ACID; LEAD; CADMIUM; NI(II);
D O I
10.1016/j.talanta.2010.03.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stable extractor of metal ions was synthesized through azo linking of p-hydroxybenzoic acid with Amberlite XAD-4 and was characterized by elemental analyses, infrared spectral and thermal studies Its water regain value and hydrogen ion capacity were found to be 15.80 and 7 52 mmol g(-1), respectively. Both batch and column methods were employed to study the sorption behavior for the metal ions which were subsequently determined by flame atomic absorption spectrophotometry The optimum pH range for Co(II), Ni(II), Cu(II), Zn(II), and Pb(II) ions were 10.0, 8 0-9 0, 7 0, 7 0-8 0 and 7 0-8.0, respectively. The half-loading time, t(1/2), are 6 0, 8.0, 8 0, 8 0 and 40 min, respectively. Comparison of breakthrough and overall capacities of the metals ascertains the high degree of column utilization (>75%) The breakthrough capacities for Co(II), Ni(II), Cu(II), Zn(II), and Pb(II) ions were found to be 0 46, 0 43, 0 42, 0 09 and 0.06 mmol g(-1) with the corresponding preconcentration factor of 460, 460, 460, 360 and 260, respectively The limit of preconcentration was in the range of 4 3-7.6 mu g L-1 The detection limit for Co(II). Cu(II), Zn(II) and Pb(II) were found to be 0 47, 0.45, 0 50, 0 80, and 1 37 mu g L-1, respectively The Student's t (t-test) values for the analysis of standard reference materials were found to be less than the critical Student's t values at 95% confidence level The AXAD-4-HBA has been successfully applied for the analysis of natural water, multivitamin formulation, Infant milk substitute, hydrogenated oil and fish (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:1772 / 1780
页数:9
相关论文
共 52 条
[1]  
[Anonymous], 2005, HARRISONS PRINCIPLES
[2]  
Bearnish F. E., 1966, ANAL CHEM NOBLE META, P41
[3]   Polymer-supported reagents for the selective complexation of metal ions: an overview [J].
Beauvais, RA ;
Alexandratos, SD .
REACTIVE & FUNCTIONAL POLYMERS, 1998, 36 (02) :113-123
[4]   Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[5]  
Bilba D, 1998, CROAT CHEM ACTA, V71, P155
[6]   EFFECT OF PHYSICOCHEMICAL HETEROGENEITY OF NATURAL COMPLEXANTS .2. BUFFERING ACTION AND ROLE OF THEIR BACKGROUND SITES [J].
BUFFLE, J ;
ALTMANN, RS ;
FILELLA, M .
ANALYTICA CHIMICA ACTA, 1990, 232 (01) :225-237
[7]  
Castro Gustavo Rocha de, 2004, Mat. Res., V7, P329
[8]   Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[9]  
Chang L. W, 1986, BASIC ENV TOXICOLOGY, P121
[10]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222