Simulation of Line Surge Arresters for Lightning Protection in 10kV Transmission Lines

被引:0
|
作者
Wang Yong [1 ]
Xie Pu [1 ]
Zhao Jin-cheng [1 ]
Zhang Gui-fang [2 ]
机构
[1] Ordance Engn Coll, Dept Elect Engn, Shijiazhuang 050003, Peoples R China
[2] PLA, Unit 73085, Xuzhou 221011, Jiangsu Prov, Peoples R China
关键词
Line surge arresters; transmission lines; PSCAD/EMTDC; lightning-prone section;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the line surge arrester and its principle, as well as the modeling of 10kV transmission lines including line surge arresters. Cases with different numbers of arresters are simulated and analyzed by the electromagnetic transient program PSCAD/EMTDC. Simulation results show that installing line surge arresters can evidently reduce the surge current and overvoltage in the lines. It is an economical and effective way to reconstruct the lightning-prone sections and phases of the 10kV lines with proper numbers of line surge arresters.
引用
收藏
页码:269 / +
页数:2
相关论文
共 50 条
  • [21] Lightning protection of the overhead transmission lines long spans without ground wires by using line arresters
    Savic, Milan
    Banjanin, Mladen
    2024 23RD INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA, INFOTEH, 2024,
  • [22] Application of line surge arresters to double-circuit transmission lines
    Institute of Industrial Science, University of Tokyo, Tokyo, Japan
    不详
    Int. Symp. Light. Prot., XI SIPDA, 2011, (312-318):
  • [23] 110- to 330-kV substation surge protection against lightning surge coming from transmission lines
    N. A. Mufid-Zade
    H. Houassine
    S. M. Tagi-Zade
    Russian Electrical Engineering, 2012, 83 (8) : 447 - 452
  • [24] The Lightning Contingency Probability Analysis on Transmission Tower with Line Arresters Protection
    Kuo, Cheng-Chien
    Chang, Hong-Chan
    Chen, Fu-Hsien
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [25] Practical methodology for modeling and simulation of a lightning protection system using metal-oxide surge arresters for distribution lines
    Araujo, Marcel A.
    Flauzino, Rogerio A.
    Altafim, Ruy A. C.
    Batista, Oureste E.
    Moraes, Lucas A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 118 : 47 - 54
  • [26] CALCULATING SURGE IMPEDANCE OF COUNTERPOISES IN LIGHTNING PROTECTION OF TRANSMISSION LINES
    ANNENKOV, VZ
    ELECTRICAL TECHNOLOGY, 1970, 1 : 133 - &
  • [27] Probabilistic evaluation of failure risk of transmission line surge arresters caused by lightning flash
    Shariatinasab, Reza
    Ajri, Farid
    Daman-Khorshid, Hadiseh
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (02) : 193 - 202
  • [28] FDTD Analysis of Metal Oxide Surge Arresters for Protection of Multiconductor Transmission Lines
    Stracqualursi, Erika
    Araneo, Rodolfo
    Lovat, Giampiero
    Burghignoli, Paolo
    PROCEEDINGS OF THE 2020 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2020,
  • [29] 220kV Transformer 10kV Side without Load Surge Arresters Selection Method
    Wang, Tianshi
    Fu, Zhe
    Wang, Huipu
    Li, Yicheng
    Zhang, Jingyi
    Xiu, Qiong
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1289 - 1292
  • [30] Application of line surge arresters for voltage uprating and compacting of overhead transmission lines
    Filipovic-Grcic, Bozidar
    Uglesic, Ivo
    Pavic, Ivica
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 830 - 835