Detachable nanoladders: A new method for signal identification and their application in the detection of ochratoxin A (OTA)

被引:35
作者
Shao, Xiangli [1 ,2 ]
Zhu, Longjiao [2 ]
Feng, Yuxiang [2 ]
Zhang, Yangzi [2 ]
Luo, Yunbo [1 ,2 ]
Huang, Kunlun [1 ,2 ,3 ]
Xu, Wentao [1 ,2 ,3 ]
机构
[1] China Agr Univ, Coll Food Sci & Nutr Engn, Beijing Adv Innovat Ctr Food Nutr & Human Hlth, Beijing 100083, Peoples R China
[2] China Agr Univ, Coll Food Sci & Nutr Engn, Key Lab Safety Assessment Genetically Modified Or, Beijing 100083, Peoples R China
[3] China Agr Univ, Coll Food Sci & Nutr Engn, Beijing Lab Food Qual & Safety, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Detachable nanoladders; Graphene oxide; Aptamer; OTA; Fluorescence biosensor; GRAPHENE OXIDE; IN-VIVO; DNA; GOLD; CARBON; AMPLIFICATION; MOLECULES;
D O I
10.1016/j.aca.2019.08.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive fluorescence turn-off biosensor for the detection of ochratoxin A (OTA) was developed based on graphene oxide (GO) and an aptamer-induced detachable nanoladders. In this assay, two types of ssDNA (H1 and H2) were involved in the assembly of the DNA nanoladders, in which H1 was labeled with fluorophore, and H2 was the OTA binding aptamer. Self-assembly of the DNA nanoladders with the addition of GO weakened its adsorption and the fluorescence intensity remained strong. In the presence of OTA, the aptamer was specifically recognized and an aptamer-OTA complex was formed, leading to the detached of DNA nanoladders. With the addition of GO, the released H1 was adsorbed on the GO surface, thus efficiently quenching the fluorescence signal (turning off). The detection limit of OTA in this assay was 4.59 nM. To improve the sensitivity of this strategy, we creatively developed an alternative strategy to replace the sturdy nanoladders with frail nanoladders. More precisely, the sequences of H1 had mismatched bases, which, when hybridized with H2 could be used to create long non-perfect complementary nanoladders. For the mismatched bases-based frail nanoladders, it was easier for OTA to bind its aptamer sequence, thus enabling a more thorough and faster detachment of the nanoladders, along with a greater degree of fluorescence quenching. The detection limit for OTA was estimated to be 0.1 nM. The biosensors we developed were sensitive, specific, enzyme-free, cost-effective and can be applied in red wine samples spiked with known concentration of OTA. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 35 条
[1]   Honeycomb Carbon: A Review of Graphene [J].
Allen, Matthew J. ;
Tung, Vincent C. ;
Kaner, Richard B. .
CHEMICAL REVIEWS, 2010, 110 (01) :132-145
[2]   DNA nanomachines [J].
Bath, Jonathan ;
Turberfield, Andrew J. .
NATURE NANOTECHNOLOGY, 2007, 2 (05) :275-284
[3]   PREDICTING DNA DUPLEX STABILITY FROM THE BASE SEQUENCE [J].
BRESLAUER, KJ ;
FRANK, R ;
BLOCKER, H ;
MARKY, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (11) :3746-3750
[4]   DNA Nanostructures at the Interface with Biology [J].
Bujold, Katherine E. ;
Lacroix, Aurelie ;
Sleiman, Hanadi F. .
CHEM, 2018, 4 (03) :495-521
[5]  
Chen G.N., 2009, ANGEW CHEM, V121, P4879, DOI DOI 10.1002/ange.200901479
[6]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[7]   Mercury nanoladders: a new method for DNA amplification, signal identification and their application in the detection of Hg(II) ions [J].
Feng, Yuxiang ;
Shao, Xiangli ;
Huang, Kunlun ;
Tian, Jingjing ;
Mei, Xiaohong ;
Luo, Yunbo ;
Xu, Wentao .
CHEMICAL COMMUNICATIONS, 2018, 54 (58) :8036-8039
[8]   Chemiluminescent and Chemiluminescence Resonance Energy Transfer (CRET) Detection of DNA, Metal Ions, and Aptamer-Substrate Complexes Using Hemin/G-Quadruplexes and CdSe/ZnS Quantum Dots [J].
Freeman, Ronit ;
Liu, Xiaoqing ;
Willner, Itamar .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (30) :11597-11604
[9]   Highly-Efficient Gating of Solid-State Nanochannels by DNA Supersandwich Structure Containing ATP Aptamers: A Nanofluidic IMPLICATION Logic Device [J].
Jiang, Yanan ;
Liu, Nannan ;
Guo, Wei ;
Xia, Fan ;
Jiang, Lei .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (37) :15395-15401
[10]   A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors [J].
Krishnan, Siva Kumar ;
Singh, Eric ;
Singh, Pragya ;
Meyyappan, Meyya ;
Nalwa, Hari Singh .
RSC ADVANCES, 2019, 9 (16) :8778-8881