Initial evaluation of automated treatment planning software

被引:70
作者
Gintz, Dawn [1 ]
Latifi, Kujtim [1 ]
Caudell, Jimmy [1 ]
Nelms, Benjamin [2 ]
Zhang, Geoffrey [1 ]
Moros, Eduardo [1 ]
Feygelman, Vladimir [1 ]
机构
[1] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, 12902 Magnolia Dr, Tampa, FL 33612 USA
[2] Canis Lupus LLC, Merrimac, WI USA
关键词
automated treatment planning; treatment plan quality; head and neck treatment planning; INTENSITY-MODULATED RADIOTHERAPY; CLINICAL-PRACTICE; BREAST-CANCER; PARETO FRONTS; OPTIMIZATION; TARGET; DELINEATION; OBJECTIVES; HEAD;
D O I
10.1120/jacmp.v17i3.6167
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Even with advanced inverse-planning techniques, radiation treatment plan optimization remains a very time-consuming task with great output variability, which prompted the development of more automated approaches. One commercially available technique mimics the actions of experienced human operators to progressively guide the traditional optimization process with automatically created regions of interest and associated dose-volume objectives. We report on the initial evaluation of this algorithm on 10 challenging cases of locoreginally advanced head and neck cancer. All patients were treated with VMAT to 70 Gy to the gross disease and 56 Gy to the elective bilateral nodes. The results of post-treatment autoplanning (AP) were compared to the original human-driven plans (HDP). We used an objective scoring system based on defining a collection of specific dosimetric metrics and corresponding numeric score functions for each. Five AP techniques with different input dose goals were applied to all patients. The best of them averaged the composite score 8% lower than the HDP, across the patient population. The difference in median values was statistically significant at the 95% confidence level (Wilcoxon paired signed-rank test p = 0.027). This result reflects the premium the institution places on dose homogeneity, which was consistently higher with the HDPs. The OAR sparing was consistently better with the APs, the differences reaching statistical significance for the mean doses to the parotid glands (p < 0.001) and the inferior pharyngeal constrictor (p = 0.016), as well as for the maximum doses to the spinal cord (p = 0.018) and brainstem (p = 0.040). If one is prepared to accept less stringent dose homogeneity criteria from the RTOG 1016 protocol, nine APs would comply with the protocol, while providing lower OAR doses than the HDPs. Overall, AP is a promising clinical tool, but it could benefit from a better process for shifting the balance between the target dose coverage/homogeneity and OAR sparing.
引用
收藏
页码:331 / 346
页数:16
相关论文
共 30 条
[1]  
Bedford James L, 2004, J Appl Clin Med Phys, V5, P1, DOI 10.1120/jacmp.2020.25271
[2]  
Bezjak A, 2013, RTOG 0813 SEAMLESS P
[3]   Dose-volume modeling of salivary function in patients with head-and-neck cancer receiving radiotherapy [J].
Blanco, AI ;
Chao, KSC ;
El Naqa, I ;
Franklin, GE ;
Zakarian, K ;
Vicic, M ;
Deasy, JO .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1055-1069
[4]   IMRT dose shaping with regionally variable penalty scheme [J].
Cotrutz, C ;
Xing, L .
MEDICAL PHYSICS, 2003, 30 (04) :544-551
[5]   Exploration of tradeoffs in intensity-modulated radiotherapy [J].
Craft, D ;
Halabi, T ;
Bortfeld, T .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) :5857-5868
[6]   How many plans are needed in an IMRT multi-objective plan database? [J].
Craft, David ;
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2785-2796
[7]   RADIOTHERAPY DOSE-VOLUME EFFECTS ON SALIVARY GLAND FUNCTION [J].
Deasy, Joseph O. ;
Moiseenko, Vitali ;
Marks, Lawrence ;
Chao, K. S. Clifford ;
Nam, Jiho ;
Eisbruch, Avraham .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :S58-S63
[8]   PAROTID GLAND FUNCTION AFTER RADIOTHERAPY: THE COMBINED MICHIGAN AND UTRECHT EXPERIENCE [J].
Dijkema, Tim ;
Raaijmakers, Cornelis P. J. ;
Ten Haken, Randall K. ;
Roesink, Judith M. ;
Braam, Petra M. ;
Houweling, Anette C. ;
Moerland, Marinus A. ;
Eisbruch, Avraham ;
Terhaard, Chris H. J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (02) :449-453
[9]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[10]   Initial dosimetric evaluation of SmartArc - a novel VMAT treatment planning module implemented in a multi-vendor delivery chain [J].
Feygelman, Vladimir ;
Zhang, Geoffrey ;
Stevens, Craig .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01) :99-116