Mimicking peroxidase activity of Co2(OH)2CO3-CeO2 nanocomposite for smartphone based detection of tumor marker using paper-based microfluidic immunodevice

被引:64
作者
Alizadeh, Negar [1 ]
Salimi, Abdollah [1 ,2 ]
Hallaj, Rahman [1 ,2 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj 6617715175, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj 6617715175, Iran
关键词
Cobalt-Cerium nanocomposite; Mimicking peroxidase; Paper-based microfluidic; Colorimetric; Immunosensor; Smartphone; Carcinoembryonic antigen; Tumor marker; ULTRASENSITIVE MULTIPLEXED DETECTION; CARCINOEMBRYONIC ANTIGEN; ELECTROCHEMICAL IMMUNOSENSOR; SENSITIVE DETECTION; GRAPHENE OXIDE; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; NANOPARTICLES; DEVICES; FABRICATION;
D O I
10.1016/j.talanta.2018.06.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a paper-based microfluidic colorimetric immunosensor for the detection of carcinoembryonic antigen (CEA), using Co-2(OH)(2)CO3-CeO2 nanocomposite with extraordinary intrinsic peroxidase like activity. The morphology and composition of the nanocomposite characterized with Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) techniques. The proposed immunosensor facilely fabricated by loading mixture of ionic liquid and chitosan functionalized primary antibodies (Ab(1)) on the surface of paper. Compared to traditional paper based immunodevice, when ionic liquid was used the nonspecific binding protein from the paper surface was more effectively removed. Secondary antibodies (Ab(2)) were stacked on the surface of the carboxylated Co-2(OH)(2)CO3-CeO2 nanocomposite. The immunosensor response was obtained by a color change resulting from Co-2(OH)(2)CO3-CeO2 nanocomposite catalyzing the oxidation of 3,3',5,5'-tetramethyl benzidine in the presence of H2O2. The colorimetric sensing was accomplished on the paper, using smartphone for taking a photo and then analyzing the colors with an installed application. Detection of CEA was performed by this method with a linear range from 0.002 to 75.0 ng mL(-1) and a detection limit of 0.51 pg mL(-1). In this paper we developed simple, cost-effective and portable design for sensitive immunoassay and point-of-care diagnostics of cancer marker.
引用
收藏
页码:100 / 110
页数:11
相关论文
共 50 条
  • [31] Structured Porous Carbon-Based Catalysts: Cu-ZnO/CMK-3 and Cu-CeO2/CMK-3 for Direct CO2 Conversion to Methanol
    Limleamthong, Phantisa
    Chuchuan, Anurak
    Thepphankulngarm, Nattanida
    Kongkachuichay, Paisan
    TOPICS IN CATALYSIS, 2023, 66 (19-20) : 1515 - 1526
  • [32] Catalytic activity of plasma-deposited Co3O4-based thin films for CO2 hydration-A new approach to carbon capture applications
    Kierzkowska-Pawlak, Hanna
    Kruszczak, Ewelina
    Tyczkowski, Jacek
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2022, 304
  • [33] Wet chemical etching of ZnO films using NH x -based (NH4)2CO3 and NH4OH alkaline solution
    Kim, Jae-Kwan
    Lee, Ji-Myon
    JOURNAL OF MATERIALS SCIENCE, 2017, 52 (22) : 13054 - 13063
  • [34] Fabrication of a disposable electrode based on recordable gold compact disc modified with Bi-Bi2O2CO3@ graphitic carbon nitride nanocomposite for the simultaneous detection of mesalazine and uric acid in biological fluids
    Sotoudeh, Saeideh
    Sadeghi, Susan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1010
  • [35] High-performance gas sensor based on Ag@SnO2-Co3O4 hollow nanocomposite for fast and highly selective H2S detection
    Qin, Yuxiang
    Zhang, Yizhe
    Lei, Jing
    Lei, Songyuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 428
  • [36] Mesoporous nanocomposite sensors based on Sn1-xCexO2-δ metastable solid solution with high percentage of Ce3+ valence state for selective detection of H2 and CO
    Somacescu, Simona
    Osiceanu, Petre
    Moreno, Jose Maria Calderon
    Navarrete, Laura
    Serra, Jose Manuel
    MICROPOROUS AND MESOPOROUS MATERIALS, 2013, 179 : 78 - 88
  • [37] Hollow porous N-doped carbon-based Co4N with peroxidase-like activity for detection of H2O2 under non-physiologic conditions
    Tao, Na
    Xu, Ying
    Wang, Liqiang
    Yang, Wenjie
    Liu, You-Nian
    MICROCHEMICAL JOURNAL, 2021, 166
  • [38] Mechanism of Co3O4/graphene catalytic activity in Li-O2 batteries using carbonate based electrolytes
    Lim, Hee-Dae
    Gwon, Hyeokjo
    Kim, Haegyeom
    Kim, Sung-Wook
    Yoon, Taeho
    Choi, Jang Wook
    Oh, Seung M.
    Kang, Kisuk
    ELECTROCHIMICA ACTA, 2013, 90 : 63 - 70
  • [39] Assessment of Oxidative Stress by Detection of H2O2 in Rye Samples Using a CuO- and Co3O4-Nanostructure-Based Electrochemical Sensor
    Mihailova, Irena
    Krasovska, Marina
    Sledevskis, Eriks
    Gerbreders, Vjaceslavs
    Mizers, Valdis
    Ogurcovs, Andrejs
    CHEMOSENSORS, 2023, 11 (10)
  • [40] Response characteristics of a potentiometric CO2 gas sensor based on Li3PO4 solid electrolyte using Au film as the electrodes
    Sun, Guoliang
    Wang, Hairong
    Li, Peng
    Liu, Zhen
    Jiang, Zhuangde
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (12)