Ionic liquid as a mobile phase additive in high-performance liquid chromatography for the simultaneous determination of eleven fluorescent whitening agents in paper materials

被引:29
作者
Wang, Qing [1 ,2 ]
Chen, Xianbo [3 ]
Qiu, Bin [3 ]
Zhou, Liang [3 ]
Zhang, Hui [1 ,2 ]
Xie, Juan [1 ,2 ]
Luo, Yan [1 ,2 ]
Wang, Bin [1 ,2 ]
机构
[1] Xiangnan Univ, Coll Pharm, Chenzhou 423043, Hunan, Peoples R China
[2] Xiangnan Univ, Key Lab Cardiocerebrovascu Nat Drug Res Hunan Pro, Chenzhou 423043, Hunan, Peoples R China
[3] Chenzhou City Ctr Dis Control & Prevent, Chanzhou, Hunan, Peoples R China
关键词
Fluorescent whitening agents; Ionic liquids; Liquid chromatography; Separation mechanisms; TANDEM MASS-SPECTROMETRY; HETEROCYCLIC AROMATIC-AMINES; CAPILLARY-ELECTROPHORESIS; SEPARATION; EXTRACTION; MODIFIER; BEHAVIOR; PHENOLS; IMPROVE; SAMPLES;
D O I
10.1002/jssc.201501050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, 11 4,4'-diaminostilbene-2,2'-disulfonic acid based fluorescent whitening agents with different numbers of sulfonic acid groups were separated by using an ionic liquid as a mobile phase additive in high-performance liquid chromatography with fluorescence detection. The effects of ionic liquid concentration, pH of mobile phase B, and composition of mobile phase A on the separation of fluorescent whitening agents were systematically investigated. The ionic liquid tetrabutylammonium tetrafluoroborate is superior to tetrabutylammomnium bromide for the separation of the fluorescent whitening agents. The optimal separation conditions were an ionic liquid concentration at 8 mM and the pH of mobile phase B at 8.5 with methanol as mobile phase A. The established method exhibited low limits of detection (0.04-0.07 ng/mL) and wide linearity ranges (0.30-20 ng/mL) with high linear correlation coefficients from 0.9994 to 0.9998. The optimized procedure was applied to analyze target analytes in paper samples with satisfactory results. Eleven target analytes were quantified, and the recoveries of spiked paper samples were in the range of 85-105% with the relative standard deviations from 2.1 to 5.1%. The obtained results indicated that the method was efficient for detection of 11 fluorescent whitening agents.
引用
收藏
页码:1242 / 1248
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of four amides in Saururus chinensis by matrix solid phase dispersion and high-performance liquid chromatography method
    Chen, Hongjiang
    Liu, Jianan
    Cui, Mingchao
    Chen, Jianwei
    Li, Xiang
    Chen, Yong
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2018, 26 (01) : 362 - 368
  • [42] Effect of ionic liquids as mobile phase additives on retention of catecholamines in reversed-phase high-performance liquid chromatography
    Zhang, WZ
    He, LJ
    Gu, YL
    Liu, X
    Jiang, SX
    [J]. ANALYTICAL LETTERS, 2003, 36 (04) : 827 - 838
  • [43] Simultaneous separation and determination of seven chelating agents using high-performance liquid chromatography based on statistics design
    Liu, Zihe
    Chen, Yuancai
    Hu, Yongyou
    [J]. JOURNAL OF SEPARATION SCIENCE, 2020, 43 (04) : 719 - 726
  • [44] Fluoroquinolone antibiotic determination in bovine, ovine and caprine milk using solid-phase extraction and high-performance liquid chromatography-fluorescence detection with ionic liquids as mobile phase additives
    Herrera-Herrera, Antonio V.
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (43) : 7281 - 7287
  • [45] Quinolinium ionic liquid-modified silica as a novel stationary phase for high-performance liquid chromatography
    Sun, Min
    Feng, Juanjuan
    Luo, Chuannan
    Liu, Xia
    Jiang, Shengxiang
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) : 2651 - 2658
  • [46] Deep Eutectic Solvent Based Reversed-Phase Dispersive Liquid-Liquid Microextraction and High-Performance Liquid Chromatography for the Determination of Free Tryptophan in Cold-Pressed Oils
    Razic, Slavica
    Bakic, Tamara
    Topic, Aleksandra
    Lukic, Jelena
    Onjia, Antonije
    [J]. MOLECULES, 2023, 28 (05):
  • [47] Effect of Ionic Liquids as Mobile-Phase Additives on Chromatographic Parameters of Neuroleptic Drugs in Reversed-Phase High-Performance Liquid Chromatography
    Flieger, J.
    [J]. ANALYTICAL LETTERS, 2009, 42 (11) : 1632 - 1649
  • [48] Determination of phenols in environmental water samples by ionic liquid-based headspace liquid-phase microextraction coupled with high-performance liquid chromatography
    Ye, Cunling
    Zhou, Qingxiang
    Wang, Xinming
    Xiao, Junping
    [J]. Journal of Separation Science, 2007, 30 (01) : 42 - 47
  • [49] Hollow fiber supported ionic liquid membrane microextraction for determination of sulfonamides in environmental water samples by high-performance liquid chromatography
    Tao, Yong
    Liu, Jing-Fu
    Hu, Xia-Lin
    Li, Hong-Cheng
    Wang, Thanh
    Jiang, Gui-Bin
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (35) : 6259 - 6266
  • [50] In-syringe ionic liquid dispersive liquid-liquid microextraction for the determination of sulfonamides in blood using high-performance liquid chromatography
    Yu, Wei
    Liu, Zhongling
    Cui, Shusen
    Zhang, Shaohua
    Yang, Xiao
    Lei, Lei
    Zhang, Hanqi
    Yu, Aimin
    [J]. ANALYTICAL METHODS, 2014, 6 (08) : 2545 - 2552