Smart panel with time-varying shunted piezoelectric patch absorbers for broadband vibration control

被引:34
|
作者
Casagrande, D. [1 ]
Gardonio, P. [1 ]
Zilletti, M. [2 ]
机构
[1] Univ Udine, DPIA, Via Sci, I-33100 Udine, Italy
[2] Univ Southampton, ISVR, Southampton 5017 1BJ, Hants, England
关键词
Switching control; Sweeping control; Piezoelectric shunted absorber; Piezoelectric transducer; Tuned vibration absorber; Dynamic absorber; Vibration control; IMPLEMENTATION;
D O I
10.1016/j.jsv.2017.04.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents a simulation study concerning the low and mid frequencies control of flexural vibration in a lightly damped thin plate equipped with five time-varying shunted piezoelectric patch absorbers. The panel is excited by a rain-on-the-roof broad frequency band stationary disturbance. The absorbers are composed by piezoelectric patches connected to time-varying RL shunt circuits. Discrete or continuous variations over time of the shunts are implemented in such a way as to either switch, between given values, or sweep, within certain ranges, the natural frequency and damping factor of the electro-mechanical absorbers to control either the resonant response of targeted flexural modes of the plate with natural frequency comprised between 30 Hz and 1 kHz or to control the resonant responses of all flexural modes with natural frequencies comprised between 30 Hz and 1 kHz. The proposed system is firstly presented; then, the vibration control effects produced by a single patch and by the array of five patches implementing the switching and sweeping shunts are investigated. Both time-varying operation modes produce significant vibration control effects, with reductions of the resonance peaks of the target resonances or target frequency band up to 12 dB. The piezoelectric patch absorbers with sweeping shunts offer an interesting practical solution since they are operated blindly, thus they do not require a system identification during installation and effectively work without on line tuning also on systems whose response may vary substantially in time. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 304
页数:17
相关论文
共 50 条
  • [1] Vibration control with electromagnetic and piezoelectric time-varying vibration absorbers: a comparative experimental study
    Dal Bo, L.
    Turco, E.
    Gardonio, P.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 3097 - 3111
  • [2] Smart panel with sweeping and switching piezoelectric patch vibration absorbers: Experimental results
    Dal Bo, L.
    Gardonio, P.
    Casagrande, D. E.
    Saggini, S.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 120 : 308 - 325
  • [3] Panel with self-tuning shunted piezoelectric patches for broadband flexural vibration control
    Gardonio, Paolo
    Zientek, Michal
    Dal Bo, Loris
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 134
  • [4] Vibration and noise control using shunted piezoelectric transducers: A review
    Gripp, J. A. B.
    Rade, D. A.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 112 : 359 - 383
  • [5] A semi-active shunted piezoelectric tuned mass damper for robust vibration control
    Chatziathanasiou, Grigorios M.
    Chrysochoidis, Nikolaos A.
    Saravanos, Dimitris A.
    JOURNAL OF VIBRATION AND CONTROL, 2022, 28 (21-22) : 2969 - 2983
  • [6] Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations
    Xu, Y. L.
    Huang, Q.
    Xia, Y.
    Liu, H. J.
    SMART STRUCTURES AND SYSTEMS, 2015, 15 (03) : 807 - 830
  • [7] Electromagnetic and piezoelectric time-varying units for the control of flexural vibrations of thin-walled structures
    Dal Bo, Loris
    Turco, Emanuele
    Gardonio, Paolo
    Rodrigues, Gabriel Konda
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2023, 30 (05) : 1083 - 1094
  • [8] Robust adaptive vibration control for a string with time-varying output constraint
    He, Wei
    Jing, Zhe
    He, Xiuyu
    Liu, Jin-Kun
    Sun, Changyin
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2018, 28 (17) : 5213 - 5231
  • [9] Exploring vibration control strategies for a footbridge with time-varying modal parameters
    Soria, Jose M.
    Diaz, Ivan M.
    Pereira, Emiliano
    Garcia-Palacios, Jaime H.
    Wang, Xidong
    13TH INTERNATIONAL CONFERENCE ON MOTION AND VIBRATION CONTROL (MOVIC 2016) AND THE 12TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN STRUCTURAL DYNAMICS (RASD 2016), 2016, 744
  • [10] Passive vibration control of flexible spacecraft using shunted piezoelectric transducers
    Sales, T. P.
    Rade, D. A.
    de Souza, L. C. G.
    AEROSPACE SCIENCE AND TECHNOLOGY, 2013, 29 (01) : 403 - 412