Detailed Magnetic Field Monitoring of Short Circuit Defects of Excitation Winding in Hydro-generator

被引:0
作者
Ehya, H. [1 ]
Nysveen, A. [1 ]
Groth, I. L. [2 ]
Mork, B. A. [3 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Elect Power Engn, N-7034 Trondheim, Norway
[2] Siemens, Trondheim, Norway
[3] Michigan Tech Univ, Dept Elect & Comp Engn, Houghton, MI USA
来源
2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1 | 2020年
关键词
Air-gap magnetic field; condition monitoring; hall effect sensor; hydro-generators; re-sampling; short circuit defect;
D O I
10.1109/icem49940.2020.9270942
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The excitation windings of the synchronous generators are generally reliable. However, electrical, mechanical, and thermal stresses that the machine is exposed to during its operation leads to the inter-turn and ground insulation faults. On-line condition monitoring could provide a valuable real-time assessment of the synchronous generator. It could discriminate gradual aggravating defects at an incipient stage before it leads to irreversible and costly damages. On-line monitoring of the air gap magnetic field has been used in different types of electrical machines. However, some concerns should be considered when applying this method to the salient pole synchronous generators (SPSG), especially in the SPSG, with a large number of turns per poles that show less or lack of sensitivity to a fault. This difficulty could be solved by wise locating of the Hall effect sensor, choosing precise sampling rate, re-sampling the data and signal processing approach. In this paper, detailed online monitoring of the air gap magnetic field under the excitation winding defect is proposed. A procedure that could detect the severity and location of the fault-based on different analyzing methods of flux density in no-load and full load is proposed. The nominated approach is examined by using numerical modeling and a experimental test rig with a 100 kVA SPSG. It is proven that the air gap magnetic field spectrum could provide a reliable assessment of the machine under the short circuit fault of the rotor field winding.
引用
收藏
页码:2603 / 2609
页数:7
相关论文
共 7 条
  • [1] INTERTURN SHORT-CIRCUIT DETECTOR FOR TURBINE-GENERATOR ROTOR WINDINGS
    ALBRIGHT, DR
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (02): : 478 - &
  • [2] Kokoko O, 2018, 2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1815, DOI 10.1109/ICELMACH.2018.8506816
  • [3] Mork B, COMP MEASURES BENCHM
  • [4] Online Condition Monitoring of Large Synchronous Generator under Short Circuit Fault-A Review
    Sadeghi, Iman
    Ehya, Hossein
    Faiz, Jawad
    Akmal, Amir Abbas Shayegani
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, : 1843 - 1848
  • [5] Tvoric S, 2013, INT REV ELECT ENG IR, V8, P1
  • [6] Reliable Flux-Based Detection of Field Winding Failures for Salient Pole Synchronous Generators
    Yun, Jangho
    Lee, Sang Bin
    Sasic, Mladen
    Stone, Greg C.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (03) : 1715 - 1718
  • [7] Comprehensive Monitoring of Field Winding Short Circuits for Salient Pole Synchronous Motors
    Yun, Jangho
    Park, Sanguk
    Yang, Chanseung
    Park, Yonghyun
    Lee, Sang Bin
    Sasic, Mladen
    Stone, Greg C.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (03) : 1686 - 1694