Measurements of output factors with different detector types and Monte Carlo calculations of stopping-power ratios for degraded electron beams

被引:27
作者
Björk, P [1 ]
Knöös, T [1 ]
Nilsson, P [1 ]
机构
[1] Univ Lund Hosp, Dept Radiat Phys, Lund, Sweden
关键词
D O I
10.1088/0031-9155/49/19/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the present study was to investigate three different detector types (a parallel-plate ionization chamber, a p-type silicon diode and a diamond detector) with regard to output factor measurements in degraded electron beams, such as those encountered in small-electron-field radiotherapy and intraoperative radiation therapy (IORT). The Monte Carlo method was used to calculate mass collision stopping-power ratios between water and the different detector materials for these complex electron beams (nominal energies of 6, 12 and 20 MeV). The diamond detector was shown to exhibit excellent properties for output factor measurements in degraded beams and was therefore used as a reference. The diode detector was found to be well suited for practical measurements of output factors, although the water-to-silicon stopping-power ratio was shown to vary slightly with treatment set-up and irradiation depth (especially for lower electron energies). Application of ionization-chamber-based dosimetry, according to international dosimetry protocols, will introduce uncertainties smaller than 0.3% into the output factor determination for conventional IORT beams if the variation of the water-to-air stopping-power ratio is not taken into account. The IORT system at our department includes a 0.3 cm thin plastic scatterer inside the therapeutic beam, which furthermore increases the energy degradation of the electrons. By ignoring the change in the water-to-air stopping-power ratio due to this scatterer, the output factor could be underestimated by up to 1.3%. This was verified by the measurements. In small-electron-bearn dosimetry, the water-to-air stopping-power ratio variation with field size could mostly be ignored. For fields with flat lateral dose profiles (>3 x 3 cm(2)), output factors determined with the ionization chamber were found to be in close agreement with the results of the diamond detector. For smaller field sizes the lateral extension of the ionization chamber hampers its use. We therefore recommend that the readily available silicon diode detector should be used for output factor measurements in complex electron fields.
引用
收藏
页码:4493 / 4506
页数:14
相关论文
共 63 条
[1]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS - AN EXTENSION OF THE 1983 AAPM PROTOCOL REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-39 [J].
ALMOND, PR ;
ATTIX, FH ;
HUMPHRIES, LJ ;
KUBO, H ;
NATH, R ;
GOETSCH, S ;
ROGERS, DWO .
MEDICAL PHYSICS, 1994, 21 (08) :1251-1260
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]  
Andreo P., 1987, ABSORBED DOSE DETERM
[4]  
[Anonymous], 1983, MED PHYS, V10, P741
[5]  
[Anonymous], 2001, PIRS701 NAT RES COUN
[6]   Using Monte Carlo methods to commission electron beams: A feasibility study [J].
Antolak, JA ;
Bieda, MR ;
Hogstrom, KR .
MEDICAL PHYSICS, 2002, 29 (05) :771-786
[7]   The effect of scattering foil parameters on electron-beam Monte Carlo calculations [J].
Bieda, MR ;
Antolak, JA ;
Hogstrom, KR .
MEDICAL PHYSICS, 2001, 28 (12) :2527-2534
[8]   DOSIMETRY, FIELD SHAPING AND OTHER CONSIDERATIONS FOR INTRAOPERATIVE ELECTRON THERAPY [J].
BIGGS, PJ ;
EPP, ER ;
LING, CC ;
NOVACK, DH ;
MICHAELS, HB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (07) :875-884
[9]  
Björk P, 2000, MED PHYS, V27, P2580, DOI 10.1118/1.1315317
[10]   Design and dosimetry characteristics of a soft-docking system-for intraoperative radiation therapy [J].
Björk, P ;
Knöös, T ;
Nilsson, P ;
Larsson, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (02) :527-533