Heat transfer performance of steam/air flow in inverted V-shaped rib-roughened channels

被引:0
|
作者
Ma, Chao [1 ]
Ge, Bing [2 ]
机构
[1] Weifang Univ, Sch Mech Elect & Vehicle Engn, Weifang 261061, Shandong, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
关键词
Steam cooling; air cooling; inverted V-shaped ribs; rib angles; GAS-TURBINE; COOLING PERFORMANCE; RECTANGULAR DUCT; FRICTION; BLADE; ROUGHNESS;
D O I
10.1177/09576509211016177
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer performance of steam and air flow in a rough rectangular channel with different inverted V-shaped ribs was investigated by infrared thermal imaging technology. Under the conditions that the Reynolds number is in the range of 4000-15,000, the effects of the rib angle on the heat transfer enhancement of the two coolants were obtained. The rib pitch ratio of the flow channel is 10, the ratio of the rib height to the channel hydraulic diameter is 0.078, and the inverted V-shaped rib angle varies from 45 degrees to 90 degrees. The results show that in the inverted V-shaped ribbed channel, the Nu number on both sides of the channel is greatly increased, while the Nu number in the middle of the channel is lower. The local Nu distribution on the surface of the ribbed channel is highly related to the shape of the rib. For different medium cooling, the value and unevenness of the heat transfer coefficient are different, but the shape of the high and low heat transfer coefficient distribution is hardly affected. The heat transfer of both coolants increases as the rib angle decreases from 90 degrees to 45 degrees. Compared with air flow, steam flow cooling shows higher convective heat transfer enhancement. For rib angles of 45 degrees, 60 degrees, 75 degrees, and 90 degrees, under the operating condition of the Reynolds number = 12,000, the area-averaged Nusselt numbers of the steam flow is 23.6%, 27.4% and 13.9% higher than that of the air flow, respectively. Based on the experimental heat transfer data, the correlation in terms of the Reynolds number and the rib angle was developed, which is used to estimate the Nu number for steam and air cooling in the inverted V-shaped rib-roughness channels.
引用
收藏
页码:1933 / 1945
页数:13
相关论文
共 50 条
  • [1] An experimental study on convective heat transfer performance of steam and air flow in V-shaped rib roughened channels
    Ma, Chao
    Ji, Yongbin
    Zang, Shusheng
    Chen, Hua
    EXPERIMENTAL HEAT TRANSFER, 2019, 32 (01) : 51 - 68
  • [2] Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels
    Ma Chao
    Ji Yongbin
    Ge Bing
    Zang Shusheng
    Chen Hua
    JOURNAL OF THERMAL SCIENCE, 2018, 27 (02) : 184 - 194
  • [3] Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels
    Chao Ma
    Yongbin Ji
    Bing Ge
    Shusheng Zang
    Hua Chen
    Journal of Thermal Science, 2018, 27 : 184 - 194
  • [4] Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels
    MA Chao
    JI Yongbin
    GE Bing
    ZANG Shusheng
    CHEN Hua
    JournalofThermalScience, 2018, 27 (02) : 184 - 194
  • [5] Flow and heat transfer performance of steam cooling in V-shaped ribbed channels
    Ma, Chao
    Zang, Shu-Sheng
    Chen, Xiao-Ling
    Ji, Yong-Bin
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2015, 49 (05): : 644 - 650and656
  • [6] Heat transfer characteristics in steam-cooled rectangular channels with two opposite rib-roughened walls
    Liu, Jiazeng
    Gao, Jianmin
    Gao, Tieyu
    Shi, Xiaojun
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 104 - 111
  • [7] HEAT TRANSFER IN A ROTATING RIB-ROUGHENED WEDGE-SHAPED U-DUCT
    Ding, Liang
    Tian, Shuqing
    Deng, Hongwu
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,
  • [8] Numerical investigation of fluid flow and heat characteristics of a roughened solar air heater with novel V-shaped ribs
    Allauddin, Usman
    Khan, Waqar A.
    Ali, Saim E.
    Haider, Syed M. M.
    Ahmed, Abdul S.
    Rehman, Abdur
    Verdin, Patrick G.
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2022, 46 (03) : 561 - 572
  • [9] A CFD (COMPUTATIONAL FLUID DYNAMICS) BASED THERMAL PERFORMANCE OF SOLAR AIR HEATER WITH RIB-ROUGHENED CHANNELS
    Qureshi, Mumtaz Hussain
    Shakaib, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 8, 2017,
  • [10] Heat Transfer and Turbulent Flow Structure in Channels With Miniature V-Shaped Rib-Dimple Hybrid Structures on One Wall
    Zhang, Peng
    Rao, Yu
    Li, Yanlin
    Weigand, Bernhard
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2019, 141 (07):