Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: A planning comparison

被引:29
作者
Broggi, Sara [1 ]
Perna, Lucia [1 ]
Bonsignore, Francesco [2 ]
Rinaldin, Giuseppe [1 ]
Fiorino, Claudio [1 ]
Chiara, Anna [3 ]
Frigerio, Cristina [2 ]
Butti, Ivana [2 ]
Sangalli, Giulia [2 ]
Dell'Oca, Italo [3 ]
Di Muzio, Nadia [3 ]
Cattaneo, Giovanni Mauro [1 ]
Declich, Fausto [2 ]
机构
[1] Ist Sci San Raffaele, Dept Med Phys, I-20132 Milan, Italy
[2] Osped A Manzoni, Dept Med Phys, Lecce, Italy
[3] Ist Sci San Raffaele, Dept Radiotherapy, I-20132 Milan, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2014年 / 30卷 / 08期
关键词
Head and neck cancer; Volumetric arc techniques; IMRT; Dosimetrical comparison; OROPHARYNGEAL CANCER; HELICAL TOMOTHERAPY; ARC THERAPY; IMRT; CARCINOMA; SMARTARC; SHOOT; STEP;
D O I
10.1016/j.ejmp.2014.07.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare helical Tomotherapy (HT), two volumetric-modulated arc techniques and conventional fixed-field intensity modulated techniques (S-IMRT) for head-neck (HN) cancers. Methods and materials: Eighteen HN patients were considered. Four treatment plans were generated for each patient: HT, S-IMRT optimised with Eclipse treatment planning system and two volumetric techniques using Elekta-Oncentra approach (VMAT) and Varian-RapidArc (RA), using two full arcs. All techniques were optimised to simultaneously deliver 66Gy to PTV1 (GTV and enlarged nodes) and 54Gy to PTV2 (subclinical and electively treated nodes). Comparisons were assessed on several dosimetric parameters and, secondarily, on planned MUs and delivery time. Results: Concerning PTV coverage, significantly better results were found for HT and RA. HT significantly improved the target coverage both compared to S-IMRT and VMAT. No significant differences were found between S-IMRT and volumetric techniques in terms of dose homogeneity. For OARs, all the techniques were able to satisfy all hard constraints; significantly better results were found for HT, especially in the intermediate dose range (15-30 Gy). S-IMRT reached a significantly better OARs sparing with respect to VMAT and RA. No significant differences were found for body mean dose, excepting higher values of V5 -V10 for HT. A reduction of planned MUs and delivery treatment time was found with volumetric techniques. Conclusions: The objectives of satisfying target coverage and sparing of critical structures were reached with all techniques. S-IMRT techniques were found more advantageous compared to RA and VMAT for OARs sparing. HT reached the best overall treatment plan quality. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:973 / 979
页数:7
相关论文
共 15 条
[1]   SMARTARC-BASED VOLUMETRIC MODULATED ARC THERAPY FOR OROPHARYNGEAL CANCER: A DOSIMETRIC COMPARISON WITH BOTH INTENSITY-MODULATED RADIATION THERAPY AND HELICAL TOMOTHERAPY [J].
Clemente, Stefania ;
Wu, BinBin ;
Sanguineti, Giuseppe ;
Fusco, Vincenzo ;
Ricchetti, Francesco ;
Wong, John ;
McNutt, Todd .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04) :1248-1255
[2]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[3]   Modeling the dosimetry of organ-at-risk in head and neck IMRT planning: An intertechnique and interinstitutional study [J].
Lian, Jun ;
Yuan, Lulin ;
Ge, Yaorong ;
Chera, Bhishamjit S. ;
Yoo, David P. ;
Chang, Sha ;
Yin, FangFang ;
Wu, Q. Jackie .
MEDICAL PHYSICS, 2013, 40 (12)
[4]   Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT [J].
Lu, Szu-Huai ;
Cheng, Jason Chia-Hsien ;
Kuo, Sung-Hsin ;
Lee, Jason Jeun-Shenn ;
Chen, Liang-Hsin ;
Wu, Jian-Kuen ;
Chen, Yu-Lisuan ;
Chen, Wan-Yu ;
Wen, Shu-Yu ;
Chong, Fok-Ching ;
Wu, Chien-Jang ;
Wang, Chun-Wei .
RADIOTHERAPY AND ONCOLOGY, 2012, 104 (03) :324-330
[5]   Volumetric modulated arc therapy: IMRT in a single gantry arc [J].
Otto, Karl .
MEDICAL PHYSICS, 2008, 35 (01) :310-317
[6]   Helical tomotherapy superficial dose measurements [J].
Ramsey, Chester R. ;
Seibert, Rebecca M. ;
Robison, Benjamin ;
Mitchell, Martha .
MEDICAL PHYSICS, 2007, 34 (08) :3286-3293
[7]  
Rao M, MED PHYS, V37, P1350
[8]   Scintigraphic assessment of early and late parotid gland function after radiotherapy for head-and-neck cancer: A prospective study of dose-volume response relationships [J].
Roesink, JM ;
Moerland, MA ;
Hoekstra, A ;
Van Rijk, PP ;
Terhaard, CHJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1451-1460
[9]   Dosimetric predictors of laryngeal edema [J].
Sanguineti, Giuseppe ;
Adapala, Prashanth ;
Endres, Eugene J. ;
Brack, Collin ;
Fiorino, Claudio ;
Sormani, Maria Pia ;
Parker, Brent .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :741-749
[10]   Is there a "mucosa-sparing" benefit of IMRT for head-and-neck cancer? [J].