Plain versus paclitaxel-coated balloon angioplasty in arteriovenous fistula and graft stenosis: An umbrella review

被引:14
|
作者
Lazarides, Miltos K. [1 ]
Christaina, Eleni [2 ]
Antoniou, George A. [3 ]
Argyriou, Christos [1 ]
Trypsianis, Gregory [2 ]
Georgiadis, George S. [1 ]
机构
[1] Democritus Univ, Dept Vasc Surg, Alexandroupolis, Greece
[2] Democritus Univ, Dept Biostat, Alexandroupolis, Greece
[3] Univ Manchester, Royal Oldham Hosp, Pennine Acute Hosp NHS Trust, Dept Vasc & Endovasc Surg, Manchester, Lancs, England
关键词
AV fistula; dialysis access; interventional radiology; paclitaxel; umbrella review; balloon angioplasty; systematic review; DRUG-ELUTING BALLOON; HEMODIALYSIS ACCESS; SYSTEMATIC REVIEWS; METHODOLOGICAL QUALITY; METAANALYSIS; AMSTAR;
D O I
10.1177/11297298211005290
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
An umbrella review was performed to synthesize the evidence from systematic reviews/meta-analyses of clinical trials investigating the efficacy and safety of paclitaxel-coated balloons (PCB) vs. conventional balloon angioplasty in arteriovenous fistulas (AVFs) and grafts stenosis. Medline (via PubMed) and SCOPUS databases were searched up to July 15th 2020. All meta-analyses that enrolled randomized controlled trials (RCTs) comparing PCB with plain balloons in AVFs and grafts were included. Re-analysis of original data was performed assessing predictive intervals (PI). Quality of the included meta-analyses was assessed using AMSTAR score. Eight meta-analyses were included and four clinical outcomes [target lesion primary patency (TLPP), circuit primary patency, mortality, complication rate] derived from 14 RCTs, were analyzed. There were no significant differences in the TLPP in meta-analyses providing data purely from autologous AVFs. Significant benefits regarding TLPP and circuit primary patency at 3, 6, and 12-months in favor of PCB were reported in four meta-analyses mixing AVFs and grafts; however when PI were assessed, in all but one meta-analysis these included the null value, indicating no significant benefit. In only one meta-analysis significant difference of TLPP at 12-months in favor of PCB was noticed. (Odds Ratio 0.0009 PI: 0.28-0.85) No mortality difference was noticed in four meta-analyses providing data up to 24 months. In conclusion this overview revealed a modest benefit of using PCB angioplasty compared to plain angioplasty in AVFs and graft stenosis. No increased mortality was noticed in the PCB group.
引用
收藏
页码:981 / 988
页数:8
相关论文
共 50 条
  • [11] Editor's Choice - Paclitaxel Coated Balloon Angioplasty vs. Plain Balloon Angioplasty for Haemodialysis Arteriovenous Access Stenosis: A Systematic Review and a Time to Event Meta-Analysis of Randomised Controlled Trials
    Han, Ahram
    Park, Taejin
    Kim, Hyun Jung
    Min, Sangil
    Ha, Jongwon
    Min, Seung-Kee
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (04) : 597 - 609
  • [12] Comparison of drug-coated balloon angioplasty versus conventional angioplasty for arteriovenous fistula stenosis: Systematic review and meta-analysis
    Salim, Sohail Abdul
    Tran, Hong
    Thongprayoon, Charat
    Fulop, Tibor
    Cheungpasitporn, Wisit
    JOURNAL OF VASCULAR ACCESS, 2020, 21 (03) : 357 - 365
  • [13] Safety of bailout stenting after paclitaxel-coated balloon angioplasty
    Mok, K. H.
    Wickramarachchi, U.
    Watson, T.
    Ho, H. H.
    Eccleshall, S.
    Ong, P. J. L.
    HERZ, 2017, 42 (07) : 684 - 689
  • [14] A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease
    Atsushi Funatsu
    Shigeru Nakamura
    Naoto Inoue
    Shinsuke Nanto
    Masato Nakamura
    Masashi Iwabuchi
    Kenji Ando
    Ryuta Asano
    Seiji Habara
    Shigeru Saito
    Ken kozuma
    Kazuaki Mitsudo
    Clinical Research in Cardiology, 2017, 106 : 824 - 832
  • [15] A novel constrained, paclitaxel-coated angioplasty balloon catheter
    Cremers, Bodo
    Binyamin, Gary
    Clever, Yvonne P.
    Seifert, Paul
    Konstantino, Eitan
    Kelsch, Bettina
    Bienek, Stephanie
    Speck, Ulrich
    Scheller, Bruno
    EUROINTERVENTION, 2017, 12 (17) : 2140 - 2147
  • [16] Efficacy and Safety of Paclitaxel-Coated Balloon Angioplasty for Dysfunctional Arteriovenous Fistulas: A Multicenter Randomized Controlled Trial
    Yin, Yanqi
    Shi, Yaxue
    Cui, Tianlei
    Li, Hua
    Chen, Jianghua
    Zhang, Lihong
    Yu, Zhengya
    Li, Hong
    Yan, Yan
    Wu, Kun
    Jin, Qizhuang
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 78 (01) : 19 - +
  • [17] Systematic Review and Meta-analysis of Randomized Controlled Trials of Paclitaxel-Coated Balloon Angioplasty in the Femoropopliteal Arteries: Role of Paclitaxel Dose and Bioavailability
    Katsanos, Konstantinos
    Spiliopoulos, Stavros
    Paraskevopoulos, Ioannis
    Diamantopoulos, Athanasios
    Karnabatidis, Dimitris
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (02) : 356 - 370
  • [18] Meta-Analysis on Clinical Outcomes of Paclitaxel-Coated Balloon Angioplasty in Femoral Popliteal Artery Occlusion
    Tang, Kaifeng
    Ye, J.
    Mao, S.
    Wang, H.
    Chen, Yuanyuan
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 85 (04) : 159 - 163
  • [19] Primary patency rate with paclitaxel-coated balloon angioplasty versus covered stenting of failed arteriovenous grafts: a retrospective comparative study
    Rizk, Mohamed Abd El-Monem Abd El-Salam
    EGYPTIAN JOURNAL OF SURGERY, 2022, 41 (01) : 30 - 36
  • [20] Low-Dose Paclitaxel-Coated Versus Uncoated Percutaneous Transluminal Balloon Angioplasty for Femoropopliteal Peripheral Artery Disease One-Year Results of the ILLUMENATE European Randomized Clinical Trial (Randomized Trial of a Novel Paclitaxel-Coated Percutaneous Angioplasty Balloon)
    Schroeder, Henrik
    Werner, Martin
    Meyer, Dirk-Roelfs
    Reimer, Peter
    Krueger, Karsten
    Jaff, Michael R.
    Brodmann, Marianne
    CIRCULATION, 2017, 135 (23) : 2227 - +