Electron ptychography achieves atomic-resolution limits set by lattice vibrations

被引:201
作者
Chen, Zhen [1 ]
Jiang, Yi [2 ]
Shao, Yu-Tsun [1 ]
Holtz, Megan E. [3 ,7 ]
Odstrcil, Michal [4 ,8 ]
Guizar-Sicairos, Manuel [4 ]
Hanke, Isabelle [5 ]
Ganschow, Steffen [5 ]
Schlom, Darrell G. [3 ,5 ,6 ]
Muller, David A. [1 ,6 ]
机构
[1] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[2] Argonne Natl Lab, Adv Photon Source, Lemont, IL 60439 USA
[3] Cornell Univ, Dept Mat Sci & Engn, Ithaca, NY 14853 USA
[4] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[5] Leibniz Inst Kristallzuchtung, Max Born Str 2, D-12489 Berlin, Germany
[6] Kavli Inst Cornell Nanoscale Sci, Ithaca, NY 14853 USA
[7] Colorado Sch Mines, Departure Met & Mat Engn, Golden, CO 80401 USA
[8] Carl Zeiss SMT, Carl Zeiss Str 22, D-73447 Oberkochen, Germany
基金
美国国家科学基金会;
关键词
X-RAY; TRANSMISSION MICROSCOPY; DIFFRACTION; ORTHOSCANDATE; SCATTERING; DETECTOR; DEPTH;
D O I
10.1126/science.abg2533
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. However, owing to lens aberrations and multiple scattering of electrons in the sample, the image resolution is reduced by a factor of 3 to 10. By inversely solving the multiple scattering problem and overcoming the electron-probe aberrations using electron ptychography, we demonstrate an instrumental blurring of less than 20 picometers and a linear phase response in thick samples. The measured widths of atomic columns are limited by thermal fluctuations of the atoms. Our method is also capable of locating embedded atomic dopant atoms in all three dimensions with subnanometer precision from only a single projection measurement.
引用
收藏
页码:826 / +
页数:41
相关论文
共 57 条
  • [51] Electron ptychographic phase imaging of light elements in crystalline materials using Wigner distribution deconvolution
    Yang, Hao
    MacLaren, Ian
    Jones, Lewys
    Martinez, Gerardo T.
    Simson, Martin
    Huth, Martin
    Ryll, Henning
    Soltau, Heike
    Sagawa, Ryusuke
    Kondo, Yukihito
    Ophus, Colin
    Ercius, Peter
    Jin, Lei
    Kovacs, Andras
    Nellist, Peter D.
    [J]. ULTRAMICROSCOPY, 2017, 180 : 173 - 179
  • [52] Picometre-precision analysis of scanning transmission electron microscopy images of platinum nanocatalysts
    Yankovich, Andrew B.
    Berkels, Benjamin
    Dahmen, W.
    Binev, P.
    Sanchez, S. I.
    Bradley, S. A.
    Li, Ao
    Szlufarska, Izabela
    Voyles, Paul M.
    [J]. NATURE COMMUNICATIONS, 2014, 5
  • [53] Sample tilt effects on atom column position determination in ABF-STEM imaging
    Zhou, Dan
    Mueller-Caspary, Knut
    Sigle, Wilfried
    Krause, Florian F.
    Rosenauer, Andreas
    van Aken, PeterA.
    [J]. ULTRAMICROSCOPY, 2016, 160 : 110 - 117
  • [54] Low-dose phase retrieval of biological specimens using cryo-electron ptychography
    Zhou, Liqi
    Song, Jingdong
    Kim, Judy S.
    Pei, Xudong
    Huang, Chen
    Boyce, Mark
    Mendonca, Luiza
    Clare, Daniel
    Siebert, Alistair
    Allen, Christopher S.
    Liberti, Emanuela
    Stuart, David
    Pan, Xiaoqing
    Nellist, Peter D.
    Zhang, Peijun
    Kirkland, Angus I.
    Wang, Peng
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)
  • [55] Zuo J. M., 1992, ELECT MICRODIFFRACTI
  • [56] AUTOMATED LATTICE-PARAMETER MEASUREMENT FROM HOLZ LINES AND THEIR USE FOR THE MEASUREMENT OF OXYGEN-CONTENT IN YBA2CU3O7-DELTA FROM NANOMETER-SIZED REGION
    ZUO, JM
    [J]. ULTRAMICROSCOPY, 1992, 41 (1-3) : 211 - 223
  • [57] Quantitative convergent beam electron diffraction
    Zuo, JM
    [J]. MATERIALS TRANSACTIONS JIM, 1998, 39 (09): : 938 - 946